QUICK STARTUP  GUIDE

Step1
Wash your hands before placing your nebulizer on a flat and stable surface.

Step 2
Connect the hose to compressor and fill the medication cup with the prescribed medication.

Step3
Attach the hose and mouthpiece to the medicine cup and plug in the power cord.

Step 4
Place the mouthpiece in our mouth to breathe in until all the medicine is used.

Step5
Turn off the machine when done.
Note: Prior to initial operation, the nebulizer should be thoroughly cleaned.

INTRODUCTION

Dr Trust Penguin Nebulizer – 403 is one of the best nebulizer machines for your infants and young children. The device is designed to deliver the medicine by converting it into a mist and thus it can be absorbed quickly to provide relief from the respiratory issues. lt uses compressed air to vaporize the liquid drug into tiny aerosol droplets. The machine comes with a compressor, a medicine chamber, and a transparent tube that connects the medicine container to the air compressor for medicine air transfer. The machine helps in getting rid of chronic illnesses like asthma, chest infections, COPD (Chronic Obstructive Pulmonary Disease), etc. It delivers the medication directly into the lungs and thus making people breathe easily.

INTRODUCTION

1. ON/OFF Switch 7. Nebulizerbottle
2. Handle 8. Mouthpiece
3. Air-vent openings 9. Adult mask
4. Filter 10. Pediatric mask
5. Air Outlet 11. Spare air filters
6. Air Tube

IMPORTANT SAFEGUARDS

Failure to read and observe all precautions could result in personal injury or equipment damage.

Product Cautions

  • Do not immerse the power cord or the unit in liquid.

  • Do not use while bathing.

  • Keep the unit away from water

  • Do not reach for a unit that has fallen into water-immediately unplug the unit.

  • Never operate the unit if it has any damaged parts (including power cord).

  • If it has been dropped or submerged in water. Promptly send it to a professional service provider for examination and repair.

  • The unit should not be used where flammable gas, oxygen or aerosol spray products are being used.

  • Disconnect the unit from the electrical outlet before cleaning, filling and after each use.

  • Donot use other attachments unless recommended manufacturer.

Operating Cations

  • Connect this product to an appropriate voltage outlet for your model.
  • DoNotrun this product unattended.
  • Never operate if this unit has a damaged cord or plug, if it has been dropped, or in any way, into water, if it does not work properly. Return it to a service center for repair.
  • If any abnormality occurs, discontinue use immediately until the unit has been examined and repaired.
  • Always unplug the product immediately after use.
  • Never block the air openings of the main unit or place it where the air openings may be obstructed.

Storage Cautions

  • Donot store the unit under direct sunlight, high temperature or humidity.
  • Keep the unit out of reach of small children.
  • Always keep the unit unplugged while not in use.

Cleaning Cautions

  • Donot immerse the unit in water. It may damage the unit.
  • Disconnect the unit from the electrical outlet before cleaning.
  • Clean all necessary parts after each use as instructed in the user manual.

OPERATING YOUR COMPRESSOR NEBULIZER

Prior to initial operation, the nebulizer should be thoroughly cleaned.

  1. Place your compressor nebulizer on a flat and stable surface. Be sure that you can easily reach the controls when you are seated.

  2. Open the clear cover and remove the inside accessories.

  3. Gently twist the top part of the nebulizer bottle counterclockwise to disassemble the nebulizer bottle.

  4. Fill the bottom section of the nebulizer bottle with the medication prescribed by your physician. Be sure that the cone is put inside the bottom section.

  5. Gently twist the top part clockwise to re-assemble the nebulizer. Be sure the two sections fit well.

  6. Attach one end of air tube to the base of the nebulizer bottle.

  7. Attach the other end of air tube to the air tube connector located on the front of the compressor.

  8. Attach mouthpiece or mask as per your choice to the top section of nebulizer.

  9. Plug the power cord into an appropriate electrical outlet. Make sure at this stage, the power switch is at “OFF” status.

  10. Press power switch to begin your prescribed treatment.

  11. When treatment is finished, shut off the unit and unplug it from the electrical outlet.

IMPORTANT:

The compressor motor has a thermal protector that will shut off the unit before the unit is overheated. When the thermal protector shuts the unit off, please:

  • Switch of the unit.
  • Unplug the unit from the electrical outlet.
  • Wait 30 minutes for the motor to cool down before another treatment.
  • Make sure the air openings are not obstructed.

CLEANING

It is recommended that the nebulizer, mouthpiece, and mask are thoroughly cleaned with hot water after each use and cleaned with a mild detergent after the last treatment of the day. It is suggested that the unit is disinfected after the last treatment of the day.

Rinsing (after each treatment)

  • Disconnect the air tube, nebulizer, mouthpiece, and mask.
  • Gently twist the nebulizer to open it.
  • Rinse the nebulizer, mouthpiece, and mask with water.
  • Drythem with clean soft towel or let it air dry.
  • Reassemble the nebulizer when completely dry and put these parts in a dry, sealed container.

Disinfections

  • Use one-part white vinegar with three parts distilled water.
    Make sure mixed solution is enough to submerge the nebulizer, mouthpiece, and mask.

  • Complete rinsing steps 2-3.

  • Wash nebulizer, mouthpiece and mask in warm water and a mild detergent. Then wash them in hot tap water.

  • Submerge these parts in the vinegar and water solution for thirty minutes.

  • Complete Rinsing Steps 3-5.

CLEANING THE COMPRESSOR

Wipe

  • Wipedailywithadamp cloth.
  • Donot use any powdered cleaners or soap pads, which may damage the finish.

Filter Change

  • Donotusecottonor any other materials.
  • Donotwashorcleanthe filter.
  • Always use filter.
  • Change the filter every 30 days or when the filter turns gray.

Filter Changing Procedure:
A. Remove the filter cover.
B. Replace the used filter with anewone.
C. Replace the filter cover.

REPLACEMENT PARTS & OPTIONAL ACCESSORIES

Replacement parts include adult mask, baby mask and baby pacifier inhaler. The pacifier inhaler allows baby to receive aerosol treatment easily through normal breath.

SPECIFICATION

Power AC 230V, 50Hz
Power Consumption 180 VA Max
Medication Capacity 8m1
Particle Size 0.5 to 10 p m
MMAD 3 p m
Sound Level Around 55 dBA
Average Nebulization Rate =0.3m1/min (2% Saline Solution)
Compressor Pressure Range 29 to 52 Psi (200 to 360 KPa/2 to 3.6 bar)
Operating Pressure Range 11.6 to 19 Psi (80 to 130 KPA/0.8 to 1.3 bar)
Liter Flow Range 5 – 8 Imp
Operating Temperature Range 50 °F to 104 °F (10°C to 40 °C)
Operating Humidity Range 10 to 95% RH
Storage Temperature Range -13 °F to 158 °F (-25 °C to 70 °C)
Storage Humidity Range 10 to 95 % RH
Dimensions (L x W x H) 178 x120 x234 mm
Weight 1.5 kg/1.8 kg
Standard Accessories Nebulizer bottle, air tube, mouthpiece, filters (5 pcs),

Adult mask, Child mask

CUSTOMER SUPPORT

CONTACT ADDRESS
USA
Nureca INC.USA
276 5th Avenue, Suite 704-397,
New York (NY) – 10001, USA
INDIA
Corporate Office (Mumbai)
Nureca Limited
B2-166, Time Square, 7th and 8th Floor, CTS No 349
and349-1 Western Express Highway, Andheri East,
Mumbai, Mumbai City, Maharashtra, 400069
Contact us
India: +91-7527013265 /+91-9356658436
Website: www.drtrustusa.com
Email: customercare@nureca.com
Connect with us on social networks
Facebook: @drtrust
Instagram: @drtrustisin
Youtube: NurecaUsa
COPYRIGHT©@2020 DR TRUST ALL RIGHTS RESERVED

Dr Trust 403 Junior Compressor Penguin Nebulizer - QR Code
5Scan to View Product Demo Video
www.drtrustusa.com/403

ABOUT US

Driven by the passion for innovation, we at Dr Trust endeavour to provide our customers with the latest medical inventions with the objective to promote good health and wellness all around the world. All the medical devices and health monitors provided by Or Trust are supported by accurate, latest, and groundbreaking technologies, innovated at our headquarter in NY, USA. All our products adhere to the most stringent CE and FDA guidelines and are strongly recommended by doctors and health practitioners. Our products are designed in the utmost exemplary ways to ensure that their accuracy and convenience are unrivaled. The ease of their use and operation makes them even more suitable for users of all age groups.

Dr Trust strives to enhance the quality of lifestyle by providing with the most trusted and innovative health care and wellness products. Being a renowned global leader in health care products, Dr Trust ensures that our technically efficient team works dynamically and tirelessly to provide the best of medical devices to our clients. The products that we have to offer are suitably designed for use at homes, laboratories, and hospitals. We bring to you a variety of best self medical devices, trusted and used by Doctors, medical professionals, and home users all over the world.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals