EdgeRouter ER-12P User Guide
- June 7, 2024
- EdgeRouter
Table of Contents
- Package Contents
- Installation Requirements
- Hardware Overview
- Wall Mounting
- Grounding the EdgeRouter (Recommended)
- Connecting Power
- Using SFP Ports
- Accessing the EdgeOS Configuration Interface
- DHCP
- Static IP Address
- UNMS Management
- Configuring PoE Settings
- Specifications
- Safety Notices
- Limited Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EdgeRouter ER-12P User Guide
Package Contents
Installation Requirements
- Wall mounting (optional)
- Drill with 6 mm drill bit
- Phillips screwdriver Wall Mount Anchors (Qty. 2) Power Cord
- For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
- For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of and destructive ESD events with industrial-grade, shielded Ethernet cable from details, visit: ui.com/toughcable
Hardware Overview
Wall Mounting
Grounding the EdgeRouter (Recommended)
The Power Adapter grounds the device; however, you can add optional ESD grounding for enhanced ESD protection (ground wire not included).
Optional
Connecting Power
Using SFP Ports
For information about compatible fiber SFP modules, visit: ubnt.link/SFP_DAC_Compatibility
Accessing the EdgeOS Configuration Interface
The EdgeOS® configuration interface can be accessed via DHCP or static IP address assignment. By default, eth1 is set up as a DHCP client, while eth0 is assigned a static IP address of 192.168.1.1. To configure the EdgeRouter, proceed to the appropriate section: DHCP or “Static IP Address”.
DHCP
- Connect an Ethernet cable from eth 1 on the Edge Router to a LAN segment that has an existing DHCP server.
- To check the IP address of the Edge Router, use one of the following methods:
- Set up the DHCP server to provide a specific IP address to the EdgeRouter based on its MAC address (on the label).
- Let the EdgeRouter obtain an IP address and then check the DHCP server to see which IP address was assigned.
Enter the Username and Password fields. Read the Ubiquiti License Click for x heck the box next to I agree to the terms of this License Table of Contents Click Login.
The EdgeOS Configuration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax
For more information on PoE configuration, refer to “Configuring PoE Settings”.
Static IP Address
-
Connect an Ethernet cable from the Ethernet port on your computer to the port labeled eth0 on the EdgeRouter.
-
Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet.
-
Launch your web browser. Type https://192.168.1.1 in the address field. Press enter (PC) or return (Mac).
Agreement to accept it. Click Login.
The EdgeOS Configuration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax
For more information on PoE configuration, refer to “Configuring PoE Settings”.
UNMS Management
You can manage your device using UNMS, which lets you configure, monitor, upgrade, and back up your devices using a single application. Get started at www.unms.com
Configuring PoE Settings
The PoE setting for ports O – 9 is set to Off by default.
WARNING: Before activating PoE, ensure that the connected device supports passive PoE and the supplied voltage.
-
In the Dashboard tab, click Actions> PoE of the Ethernet port you want to configure.
-
The Interface Configuration window will appear. Select the appropriate PoE setting, and click Save.
-
The Ethernet port’s PoE LED will confirm the PoE setting.
For detailed instructions on configuring other features, please refer to the EdgeOS User Guide. The User Guide is available at ui.com/download/edgemax
Specifications
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow.
WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.
WARNING: Do not use this product in location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
-
Compliance is required with respect to voltage, frequency, and current requirements indicated Connection to a different power source than those specified may Juration, damage to the equipment or pose a fire hazard if the limitations
-
There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
-
This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and regulations. -
The product is used in Service Access Area.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an
individual basis, and, where applicable, specify arbitration instead of jury
trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference
that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ISED Canada
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.
WEEE Compliance Statement
Declaration of Conformity
Online Resources
© 2020 Ubiquiti Inc. All rights reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>