ALERTLABS SENTREE AC Monitoring System Installation Guide
- June 7, 2024
- ALERTLABS
Table of Contents
SENTREE AC Monitoring System
Safety and Installation
SAFETY & WARNINGS
WARNING: RISK OF ELECTRIC SHOCK. CAN CAUSE INJURY OR DEATH: DISCONNECT ALL
REMOTE ELECTRIC POWER SUPPLIES BEFORE SERVICING.
WARNING: CLASS 2 WIRING TO BE ROUTED AND SUPPORTED SUCH THAT IT WILL NOT
COME INTO CONTACT WITH LINE VOLTAGE WIRING OR SHARP EDGES WITHIN THE ASSEMBLY.
WARNING: REFRIGERANT CAN CAUSE FROSTBITE. AVOID DIRECT CONTACT WITH THE
SKIN. TO PROTECT HANDS IN THE EVENT OF REFRIGERANT LEAKAGE, WEAR GLOVES WHILE
INSTALLING THE SENSOR.
ALF-000008 PKG-000076-002
ACTIVATE YOUR SENTREE
Go to app.alertlabs.com or download the app for your iPhone to activate the
sensor
and get full installation instructions.
POWER REQUIREMENTS
Rated voltage – 240 VAC, single phase, 60 Hz
Rated current – 40mA
Rated power – 9.6W
Maximum power consumption – 12W
REPLACEABLE FUSE
Fuse specifications
UL Listed or Recognized Supplemental Circuit Protection
T 5.0 A H 300 VAC
Replace with same type and fuse rating Example: Bel Fuse Inc, 0ADKC5000-BE
ISED REGULATORY STATEMENTS (IC: 22365-ALB050)
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
CAN ICES-003(B) / NMB-003(B)
FCC REGULATORY STATEMENTS (FCC ID: 2AKXF-ALB050)
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
WARNING RISK OF ELECTRIC SHOCK. CAN CAUSE INJURY OR DEATH: DISCONNECT ALL
REMOTE ELECTRIC POWER SUPPLIES BEFORE SERVICING
WARNING: RF EXPOSURE COMPLIANCE The antenna(s) used for this transmitter must
be installed to provide a separation distance of at least 20 cm from all
persons and must not be co-located or operating in conjunction with any other
product antenna or transmitter.
CAUTION Installation must be performed by qualified HVAC technicians that are
certified by the local Air Conditioner and Refrigeration Licensing Agency.
Good refrigeration practices are expected to be used.
This Sentree device is intended to be connected to condenser units powered by 240 VAC, single phase, 60 Hz power and must connect to unused 1/4 inch quick connect terminals on the line side of the condenser’s contactor.
This Sentree device is intended for use on systems up to 600 psi operating
pressure.
This Sentree device is only intended for use on 15 ton residential air
conditioner units.
There shall be no cutting of wires, rearrangement of existing components in
the installed unit, cutting, drilling or welding in electrical compartments or
in other areas where such operations may damage electrical or refrigerant
components and wiring.
This product is not to be used with flammable refrigerants.
The kit assembly is suitable for locations where the assembly is occasionally
in direct contact with water, as rain or defrost water, which may be permitted
to collect inside the condensing unit.