U Deliver bolink™ Small Cap Gravity Feeding Set BK-2085 User Guide
- June 6, 2024
- U Deliver
Table of Contents
U Deliver bolink™ Small Cap Gravity Feeding Set BK-2085
Indications for Use: The U Deliver Bolink™ ENFit® Enteral Feeding Sets
are intended for over-the-counter use to deliver liquid nutritional formulas
or water to a patient’s enteral access device (feeding tube).
Device Description: The Bolink™ small cap gravity feeding set consists of
tubing (A) with a clamp (B) , a small cap with cross spike (C) ,
an ENFit® connector (D) for connecting to feeding tubes and a protective
cap (E).
The Bolink™ small cap gravity feeding set is intended to connect compatible commercially available collapsible food containers with 8mm diameter connectors to feeding tubes with ENFit® proximal connectors. Not made with natural rubber latex. Not formulated with DEHP or BPA.
Warnings:
- For enteral feeding only.
- This device incorporates an ENFit® Connector and a Cross Spike which are designed to reduce the likelihood of tubing misconnections; however, the potential to misconnect this device with connectors of other healthcare applications still exists.
- Small parts are a potential choking hazard if this device is not used as intended. Use under adult supervision. Precautions:
- This device should be discarded after 24 hours and replaced with a new device.
- For single patient use only.
- Dispose with household waste. Do not recycle.
Instructions for Use
- Confirm feeding tube position and flush following manufacturer’s instructions.
- Close clamp (B) on Bolink™ Tubing (A).
- Remove cap on food pouch, attach screw cap (C) to food pouch and confirm cap is secured tightly.
- Open clamp (B) and squeeze food pouch to fill Bolink™ tubing (A).
- When tubing is filled, close clamp (B).
- Remove protective cover (E), use ENFit® connector to attach BolinkTM tubing to feeding tube. If the feeding tube has a funnel connector instead of an ENFit® connector use a transition connector with Christmas tree tip.
- Open clamp (B) and squeeze container with steady, consistent pressure to deliver nutrition.
- When finished, close clamp (B), disconnect BolinkTM tubing (A) from feeding tube and food pouch.
- Flush Bolink™ tubing (A) with tap water by holding under a faucet and letting water flow through the tubing until the water runs clear.
- Flush feeding tube following manufacturer’s directions.
WARNING: Before connecting to a feeding tube, confirm that the Bolink™ tubing is being connected to a feeding tube only. DO NOT connect to non- feeding tube. This includes confirming that any transitional connector with a Christmas tree tip is connected to a feeding tube and not IV tubing.
Symbol Glossary:
Catalogue number
Indicates the manufacturer’s catalogue number so that the medical device can
be identified.
Ref. 5.1.6 in ISO 15223-1:2016
| **| Use-by date**
Indicate the date after which the medical device is not to be used.
Ref. 5.1.4 in ISO 15223-1:2016
| **
---|---|---|---
Non sterile.**
Indicates a medicaI device that has not been subjected to a sterilization
process.
Ref. 5.2.7 in ISO 15223-1:2016
| **| Consult instructions for use**
Indicates the need for the user to consult the instruction for use.
Ref. 5.4.3 in ISO 15223-1:2016
|
Keep Dry.
Indicates a medical device that needs to be protected from moisture.
Ref. 5.3.4 in ISO 15223-1:2016
| **| Do not use if package is damaged**
Indicates a medical device that should not be used if the package has been
damaged or opened.
Ref. 5.2.8 in ISO 15223-1:2016
|
Do not reuse
Indicates a medical device that is intended for one use, or for use on a single patient during a single procedure.
Ref. 5.4.2 in ISO 15223-1:2016
|
| Manufacturer
Indicates the medical device manufacturer, as defined in EU Directives
90/385/EEC, 93/42/EEC and 98/79/EC.
Ref. 5.1.1 in ISO 15223-1:2016
|
Batch code
Indicates the manufacturer’s batch code so that the batch or lot can be
identified.
Ref. 5.1.5 in ISO 15223-1:2016
| ****|
For more information on Bolink™ tubing and U Deliver Medical products,
visitwww.UDeliverMedical.com.
U Deliver Medical, LLC.
7900 Excelsior Blvd, Suite 108
Hopkins, MN 55343
Made in Italy
Bolink™ is a trademark of U Deliver Medical. ENFit® is a trademark of GEDSA,
used with permission. ©2019 U Deliver Medical, LLC