Bestway 58392E Filter Pump 2500 Pool Filter Pump Owner’s Manual
- June 6, 2024
- Bestway
Table of Contents
Bestway 58392E Filter Pump 2500 Pool Filter Pump
WARNING IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING – RISK OF ELECTRIC SHOCK -The pump cannot be using while people
are inside the pool.
WARNING – TO REDUCE THE RISK OF INJURY, do not permit children to use
this product unless they are closely supervised at all times.
WARNING – RISK OF ELECTRIC SHOCK. Connect only to a grounding type
receptacle. This product is provided with a ground-fault circuit-interrupter.
If replacement of the plug is needed, use only identical replacement parts.
WARNING: The unit is provided with a ground-fault circuit-interrupter
(GFCI).
To test the GFCI, push the test button. The GFCI should interrupt power.
Push the reset button. Power should be restored. If the GFCI fails to operate
in this manner, the GFCI is defective. If the GFCI interrupts power to the
pump without the test button being pushed, a ground current is flowing,
indicating the possibility of an electric shock. Do not use this pump.
Disconnect the pump and have the problem corrected by a qualified service
representative before using.
CAUTION – To reduce the risk of electric shock the pool must be installed
no
closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable
appliances closer than 5 feet (1.5 m) from the pool.
WARNING: The pump is not intended to be bonded to the equipotential
bonding grid.
DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment.
WARNING – To reduce the risk of electric shock, replace damaged cord
immediately. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to
avoid a hazard.
WARNING – To reduce the risk of electric shock, do not use extension cord
to connect unit to electric supply; provide a properly located outlet.
CAUTION – This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is
capable of being readily disassembled for storage and reassembled to its
original integrity. A permanently-installed pool is constructed in or on the
ground or in a building such that it cannot be readily disassembled for
storage.
CAUTION – For continued protection against possible electric shock this
unit is to be mounted to the base in accordance with the installation
instructions.
IMPORTANT – Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRIC SHOCK – When working with electricity, turn the
electrical power off at the circuit breaker and lock breaker door. Failure to
do so will result in increased risk of shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE
ADAPTOR PLUGS. Consult a qualified electrician for any questions related to
the validity of your plugs grounding. Handle the pump with care. Do not pull
or carry the pump by the power cord. Never pull a plug from the outlet by
yanking the power cord. Keep cord free from abrasions. Sharp objects, oil,
moving parts, and heat should never be exposed to the filter pump.
NOTE: Please examine equipment before use. Notify Bestway at the customer
service address listed on this manual for any manufacturing defect or missing
parts at the time of purchase. Verify that the equipment components represent
the filter pump model that you had intended to purchase.
NOTE: Place pump on a solid and level ground. Pay attention to position
of pool and pump so adequate ventilation, drainage, and access for cleaning is
available. Never place pump in an area that may accumulate water, or in an
area where foot traffic will flow around the pool.
NOTE: Atmospheric conditions may affect the performance and life span of
your filter pump. Unnecessary wear and tear may occur during periods of cold,
heat and exposure to sun. Whenever possible shelter the pump from these
conditions.
NOTE: Do not add chemicals in the filter pump. NOTE: Assembly and
disassembly of this product should only be performed by adults.
- THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3
- FOR USE WITH SWIMMING POOLS ONLY.
- CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
- WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING TYPE RECEPTACLE.
- CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY – DO NOT USE WITH PERMANENTLY-INSTALLED POOLS.
- CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
- CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
- WARNING – RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin.
- Inspect Cord Before Using Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground
4) Do Not Touch Plug With Wet Hands
5) Double Insulated When Servicing Use Only Identical Replacement Parts.
6) Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
WARNING: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
–Reorient or relocate the receiving antenna.
–Increase the separation between the equipment and receiver.
–Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
–Consult the dealer or an experienced radio/ TV technician for help.
| A|
A
---|---|---
P61730
| 2| 2
P6113| 2|
2
P61731
| 1| 1
P61732| 1|
1
P61733
| 1| 1
58505/58095| 1|
1
P61734
| 1| 1
P61735| 1|
1
P61736
| 2| 2
P61738US| 1|
1
P61739
| 1| 1
P6019| 2|
2
P6517
| 2| 2
P6124| 5|
4
P6005
| 2| 2
P6029| 3|
3
P6916
| 2| 2
P61408| 1|
1
P6680
| 2| 2
P61318| 1|
0
PEDESTAL FIXING Fig.1
The filter pump must be vertically fixed on ground or a certain pedestal made
of wood or concrete before use. There should be two holes 7mm in diameter on
the pedestal, the space between which should be 256mm. Put filter pump on the
pedestal and fix them together by fasten the bolts and nuts. All the pedestal
parts should weigh over 18kgs at least to prevent the pump from accidental
falling.
Operation
- Open/unscrew the Air Purge Valves on the Filter Pump; air is released as water fills the Filter Pump.
- When water comes out of the Air Purge Valves, close both the Air Purge Valves and wipe away any water.
- Test the GFCI plug.
- Start the Filter Pump by turning on the switch to the “I” position.
GFCI Test
A. To test the GFCI plug, insert it into a grounding type receptacle.
B. Press the “RESET” button; the indicator turns red.
NOTE: If the indicator light is not on, the test has failed.
C. Press the “TEST” button. The indicator turns off.
NOTE: If the indicator light is not off, the test has failed.
D. Press the “RESET” button, the indicator light turns red, and the
filter pump is ready for use.
WARNING: RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH
USE. WARNING: DO NOT USE THE PUMP IF THE ABOVE TEST FAILS.
Please contact your local Bestway Customer Service.
NOTE: Never operate pump while the connection valves are closed.
NOTE: To prevent the risk of electrical shock, ensure your hands are
completely dry when plugging-in the Filter Pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP – Make sure both the pool’s
Inlet and Outlet valves are fully covered by water before operating the Filter
Pump.
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
- Unplug the Filter Pump.
- Stop water flowing to the Filter Pump refer to pool’s manual.
- Unscrew the Filter Cap Retainer and remove the Filter Cap.
- Clean the Filter Cartridge with a garden hose. If filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
- Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
- Check that the Filter Cap Seal is in place.
- Replace the Filter Cap and screw the Filter Cap Retainer into position.
- Open the Valve A and B.
- Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT: To ensure pool water stays clean, please clean the filter cartridge every day. For sanitary reasons we suggest replacing the Filter Cartridge with a new one every two weeks.
PUMP STORAGE
- Unplug the Filter Pump.
- Stop water flowing into the Filter Pump and to remove the Filter Cartridge.
- Discard the Filter Cartridge.
- Detach all Hoses.
- Dry all components thoroughly.
- Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-40OC (39.2-104OF)
- Drain the pool according to the Pool Owner’s Manual.
Pump Warranty
For information concerning pump warranty please visit our website at:www.bestwaycorp.com
©2018 Bestway Inflatables & Material Corp.
All rights reserved
®™ Trademarks used in some countries under license to/Marques ®™
Bestway Inflatables & Material Corp., No.3065 Cao An Road, Shanghai, 201812,
China.
Manufactured,distributed and represented in the European Union by Bestway
(Europe) S.r.l., Via Resistenza, 5, 20098 San Giuliano Milanese (Milano),
Italy
Distributed in North America by Bestway (USA) Inc., 3411 E. Harbour Drive,
Phoenix, Arizona 85034, United States of America
Tel:1-855-838-3888 (For U.S. and
Canada)
Distributed in Latin America by Distributed in Australia & New Zealand by
Bestway Australia Pty Ltd, 98-104 Carnarvon Street, Silverwater, NSW 2128,
Australia
www.bestwaycorp.com
Made in China
For support please visit us at:
www.bestwaycorp.com/support
Documents / Resources
|
Bestway 58392E Filter Pump 2500 Pool Filter
Pump
[pdf] Owner's Manual
58392E, Filter Pump 2500 Pool Filter Pump, 58392E Filter Pump 2500 Pool Filter
Pump, 2500 Pool Filter Pump, 58392E Filter Pump
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>