UNI-T UT673A Car Battery Tester Instruction Manual

June 6, 2024
UNI-T

UNI-T UT673A Car Battery Tester Instruction Manual
UNI-T UT673A Car Battery Tester Instruction Manual UNI-T UT673A Car Battery
Tester

Overview

UT673A/UT675A battery tester, with its leading-edge conductivity test technology, accurately and rapidly helps users to measure the cold cranking amps capability of the vehicle starting battery, healthy state of the battery itself, detect the common fault of vehicle starting and charging system, which helps repair vehicle quickly.

Safety information

Please carefully read this manual and follow the warning and safety information before use.

  • To avoid fire and overcurrent, please read all rated values and symbol descriptions before use.
  • Do not open the case cover. Do not turn on the tester if its cover or front panel is open.
  • Do not touch the connectors and components if the tester is powered on.
  • Please contact the authorized repair personnel to detect, repair, maintain the tester if you find any fault on it.
  • Do not use in humid, explosive or inflammable environment.
  • Keep the tester surface clean and dry. Keep it well-ventilated.

Product introduction

Interface UT673A

  1. Battery: Battery test.
  2. Crank: Vehicle Cranking system test.
  3. Charge: Vehicle Charging system test
  4. Data: The last test result can be viewed.
  5. Setting: Language setting.
  6. About: View the system information. Charge: Vehicle Charging system test

UT673A

Battery

| **
---|---
Crank| **

Charge

| **
Data| **

Setting

| **
About**|

UT675A

  1. Battery: Battery test.
  2. Crank: Vehicle Cranking system test
  3. Charge: Vehicle Charging system test.
  4. Data: The last test result can be viewed or upload.
  5. Print: Print test data.
  6. Setting: Language and time setting, view the system information.

Battery

| ****
---|---

Crank

| **
Charge| **

Data

| **
Setting| **
Print| ****

Feature

  1. Applicable to 12V battery testing and 12V/24V vehicle cranking/charging system test.
  2. Measurement standard and range:
  3. Working temperature: -20°C 50°C.
  4. Special test clip: Double-conductor Kelvin clip.
  5. Case material: Acid-resistant ABS plastic.
  6. Measurement range of battery: 30Ah—200Ah.
  7. Measurement range of voltage: 7V—16V.
  8. Portable.

Measurement standard

| Measurement range| Measurement standard| Measurement range
---|---|---|---

CCA

| 100-2000| DIN| 100-1400
BCI| 100-2000| IEC|

100-1400

CA

| 100-2000| EN| 100-2000
MCA| 100-2000| SAE|

100-2000

JIS| 26A17—245H52| Ah|

30-200Ah

Example for selecting standard

Battery identification

|

Standard

|

Battery parameter

|

Remark

---|---|---|---

12V/60Ah/CCA 500A

|

CCA

|

500

| 12V battery, the capacity is 60Ah, the cold-start current is 500A.

300A EN

|

EN

|

300

| The standard value is 300A.

12V 250Ah 60Ah DIN

|

DIN

|

250A

| 12V battery, the capacity is 60Ah, the standard value is 250A.

**26A19R 12V 60Ah**

|


JIS#

| ****

200

| 12V battery, the capacity is 60Ah, check JIS CODE conversion table and find that 26A19R corresponds to 220A for CCA.

**26A19RMF 12V 60Ah**

| ****

JIS#

|

**220**

| 12V battery, the capacity is 60Ah, check JIS CODE conversion table and find that 26A19R corresponds to 220A for MF CCA.

12V/60Ah

|

AH

|

60Ah

| If the standard is not found, estimate CCA value according to the battery capacity.

Operation instruction

  1. Connect the red and black clips of tester to the measured battery, red is positive, black is negative, the tester screen will display startup interface. If the battery voltage is lower than 7.0V, the test will become abnormal.
  2. According to the prompts, press up and down button to select:

UT673A:

  1. Battery test,
  2. Cranking test,
  3. Charging test,
  4. View test results,
  5. System setting,
  6. About.

UT675A:

  1. Battery test,
  2. Cranking test,
  3. Charging test,
  4. View test results,
  5. Print test result,
  6. Setting.

Tests below are based on 12V, 60Ah, CCA580A

Battery test

  1. Make sure engine is off.

  2. Connect to the correct polarity

  3. Select “Battery”
    Battery test

  4. Select “NORMAL BAT”




TYPE

| NORMAL BAT.
---|---

AGM BATTERY

EFB BATTERY

GEL BATTERY

  1. Select standard,CCA for example.

STANDARD

|

CCA

---|---

DIN

JIS

EN

  1. Set rated capacity of battery.

SET RATING


580 A

CCA

  1. Press ENTER to start the test.

TESTING


  1. Display test result.

G

OOD BATTERY


SOH

| 75%      495A

%

SOC|

100…………. V

R=|

3.35mΩ

Battery Test results

Description

| Interpretation
---|---

The battery is in good condition.

| The performance of storage battery is good, please continue using the battery.
The battery is in good condition, please charge the battery.|

Because the voltage of storage battery is lower than 12.3V, so the performance of storage battery is good, please continue using the storage battery after it is fully charged.

Retest after charging

|

Because the battery voltage is lower than 12V, so please retest after it is fully charged. Incorrect reading may occur

if the battery is not fully charged. Please replace the battery if “Retest after charging” displays again after charging.

Replace the battery

| Replace the storage battery.
The battery is in bad condition, replace the battery.|

Battery inside is damaged, replace the storage battery.

  1. Battery capacity (SOC): The percentage of remaining battery capacity,
    SOC=  Remaining capacity/Actual capacity×100%.

  2. Battery voltage (VOLTAGE): The voltage value of storage battery (Unit: V).

  3. Battery life (SOH): State of health of battery storage,
    SOH=Actual capacity/Nominal capacity ×100%.

  4. The measured cold-start current: The measured cold-start current of tester.

  5. Nominal cold-start current: Nominal cold-start current of storage battery

  6. Internal resistance of battery (R): The measured internal resistance of storage battery.

NOTE: For low-capacity battery (For example, the vehicle is shut down for a long time, the battery is not charged in time, the battery power is significantly lost because the vehicle door is not closed.), the tester may prompt you to “Replace battery” during actual measurement, please consult the storage battery factory and charge the battery according to the designated method, and then retest.

Cranking test

  1. **Make sure engine is off.

**

  1. Connect to the correct polarity.

  2. Select “Crank”
    Battery test

  3. Enter the interfaceof starting engine.

CRANKING TEST


START ENGINE

  1. Start engine.

  2. Engine RPM is detected.

CRANKING TEST


RPM DETECTED

  1. Automatically enter the test.

TESTING


  1. Display test result.

CRANKING NORMAL


CRANKING 11.34V

TIME                243ms

Test results

Decision

| Interpretation
---|---

Starting voltage is normal.

|

The starting voltage is higher than 9.6V.

Starting voltage is low.|

The starting voltage is lower than 9.6V.

Charging test

  1. Make sure engine is off.

  2. Connect to the correct polarity.

  3. Select “Charge”

  4. Enter the interface of starting engine.
    CHARGING TEST

    START ENGINE
    PRESS ENTER TO
    CONTINUE

  5. Start engine.

  6. Start ripple test.

RIPPLE TEST


RIPPLE TEST

5mV **12.65V**

  1. Start loaded testing

LOADED TESTING



  1. According to the prompt, Step on accelerator to increase the engine speed to 2500 R/Min and hold for 5 seconds.
    INCREASE RPM TO

    2500 R/MIN AND
    KEEP IT 5 SECONDS
    PRESS ENTER TO

  2.  Display test result.

CHARGING NORMAL


LOADED

| 14.26V
UNLOADED| 12.65V
RIPPLE|

5mV

Test results:

Decision

| Interpretation
---|---

Charging voltage is normal.

| Charging system is normal, the output voltage of engine is 13.5V~14.7V.
Charging voltage is low.|

Charging system is under-voltage, the voltage is lower than 13.5V.

Charging voltage is high.

| The voltage of charging system is higher than that of vehicle voltage stabilizer.
No voltage output.|

Generator voltage output is not detected.

Check if the connector and generator belt is normal.

Diode test.|

Test via current waveform, for example, the diode is damaged due to high ripple voltage of diode.

View test result

  • a) For UT673A, ENTER to view the last test result of Battery test, Cranking and Charging system test.
  • b) For UT675A, ENTER to view and export the last test result of Battery test, Cranking and Charging system test. Connect the computer to export the last test result via serial port and print the result.

Note: Please find the application software on our website by searching UT675A and search under Docs & Software section https://www.uni- trend.com.cn/index.php?m=content&c=index&a=show&catid=515&id=882

About (Applicable to UT673A)
ENTER to view system information.

Print test result (Applicable to UT675A)
ENTER to print the last test result of Battery test, Cranking and Charging system test.

Note: The normal working voltage of the printer is 10~16V.

Setting
ENTER to select language (English or Chinese).

Function
ENTER to enter setting page.

Language selection
User can select desired language as needed. After entering language selection page, press ENTER to select English or Chinese.

Time adjustment (Applicable to UT675A)
User can adjust or correct the system time, time sequence adjustment (Year/Month/Day/Hour/Minute) does not affect the setting of date and time format.

  • a. Press up or down button to adjust the last two digits of the YEAR, then press ENTER to confirm this adjustment and enter month adjustment.
  • Press up or down button to adjust Month, then press ENTER to confirm this adjustment and enter date adjustment.
  • c. Press up or down button to adjust DATE, then press ENTER to confirm this adjustment and enter hour adjustment.
  • d. Press up or down button to adjust HOUR, then press ENTER to confirm this adjustment and minute adjustment
  • Press up or down button to adjust MINUTE, then press ENTER until “OK” is displayed.
    After finishing the adjustment, the tester will go back to main interface. When adjusting the time, the time character will flash. By pressing and holding the button, the character will increase or decrease continuously.
    NOTE: Make sure the button is pressed for more than one second when adjusting time.
    After entering time setting, pressing return button is disabled because the system time is protected, users need to set Year/Month/Day/Hour/Minute or press return button 5 times to return.

Specification

Model

| UT673A| UT675A
---|---|---

Applicable battery

| 12V cranking lead acid battery
Battery type|

Ordinary lead acid battery, AGM flat plate battery, AGM spiral battery, GEL battery, EFB battery.

Battery capacity

| 3~250AH
Battery standard and range|

CCA:40~2000; BCI:40~2000; CA:40~2000; MCA: 40~2000; JIS:26A17~245H52; DIN:40~1400; IEC:

40~1400; EN:40~2000;SAE:40~2000; AH:3~250 AH

Voltage range

| 7~16V DC
Test method|

Four-terminal kelvin test lead

AH rapid measurement

| ****

Overvoltage protection

| **
Prevent counter voltage**|


A prompt of poor contact

| ****

Internal resistance measurement

| **
Battery life**|


Remaining battery capacity

| ****

Cranking test

| 12/24V cranking system test

Charging test

|

12/24V charging system test

USB data transfer|

/

| ****

Printing function

| /| **
LCD**|

*LCD (12864 black and white lattice)**

Language

|

Chinese and English

General


Working environment

| Temperature| 0°C~50°C
Relative humidity|

Operating: below +35°C, ≤90% Non-operating: +35°C~+40°C, ≤60%

Net weight (excluding batteries)

| 264g| 413g
Product dimension (excluding test leads)| 76mm22mm142mm|

95mm47mm183mm

Packing box dimension| 175mm45mm320mm| 285mm90mm230mm

Accessories

UT673A

| UT675A
---|---

Tester host: 1 piece

| Tester host: 1 piece
User manual: 1 piece|

User manual: 1 piece

Velcro strap: 1 piece

| USB cable: 1 piece
 |

Printing paper: 3 pieces

 |

Cloth bag: 1 piece

Maintenance

  1. Do not put or store the tester in the place where its LCD is exposed to direct sunlight for a long time. No sprays, liquids or solvents are allowed on the tester or fixtures.
  2. Please clean the dust on the tester with soft cloth. Do not scratch the protection screen of LCD. Wipe the tester with a damp but non dripping soft cloth. Never use any corrosive chemical detergents.
    Warning: Before the tester is powered on, please make sure it is completely dry to avoid short circuit caused by moisture.

Company Name
No.6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial
Developemtn Zone, Dongguan City,
Guangdong Province, China

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals