- The water system on which the operation of this product is based requires utmost care and maintenance, possibly also the use of chemicals, in order to prevent and keep the occurrence of micro-organisms and harmful bacteria, especially legionellae that are responsible for legionnaire’s disease, under control. Non-observance of this information about correct maintenance and care can entail the spreading of harmful bacteria. Due to the fact that for decorative purposes, water nozzles distribute water in the air, water droplets containing harmful bacteria can enter your lungs and cause life-threatening diseases.
- It is the responsibility of the owner of the water system and its attendant units to ensure their maintenance and care in compliance with the laws, directives and instructions laid down for this purpose. In order to avert harmful contamination, we urgently recommend the user to ensure cleaning and care of the water system and the water feature including the nozzle, and to take all necessary measures to maintain the technical units, such as pumps, tubing, connectors, under-water lighting, and nozzles to keep them in functional order in line with safety aspects. However, the maintenance and care obligation is not limited to the technical products supplied, but encompasses the entire system.
- We also recommend the owner to keep records of the dates when maintenance and care was carried out, and to document all water tests made in conjunction with the water feature. The owner is solely responsible for guaranteeing the safety of the water feature. Use or maintenance of the units sold and the system are beyond GeoGlobal Partner’s influence. GeoGlobal Partners can only be held liable for manufacturing faults of pond boss® units.
WARNING
- Risk of electrical shock. This unit is supplied with a grounding conductor and grounding–type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
- Do not exceed the voltage shown on pump and transformer.
- Always disconnect unit from the power source before beginning any maintenance or work on the unit.
- Inspect cord for damage before installation and/or maintenance. Replace the entire pump assembly if damage is found.
- Do not remove the grounding pin from the power cord plug.
-
- Risk of electrical shock: This unit has not been investigated for use in swimming pools or marine areas.
CAUTION
- This unit has been evaluated for use with fresh water only.
- Use a proper power source as indicated on the pump and transformer labels.
- Keep the cord away from high temperatures or other heat sources.
- Do not pump heated liquids.
- Do not let the unit run dry. Unit must be completely submerged up to the flotation ring for proper operation and cooling.
- Operate in fresh water only. Avoid heavily chlorinated water and water with high pH levels.
- Do not lift or pull the unit by its power cord.
- This light assembly has not been investigated for use in swimming pools or hot tubs.
PACKAGE CONTENTS
Part | Description | QTY |
---|---|---|
A | Floating Attachment Assembly with LED lights | 1 |
B | Trumpet Nozzle | 1 |
C | Single Tier Nozzle | 1 |
D | 3 Tier Nozzle | 1 |
E | Nozzle adapter (1/4 HP only) | 1 |
F | Coupler (1/4 HP only) | 1 |
G | Transformer | 1 |
H | Sensor | 1 |
I | Pump with cord for LED light | 1 |
J | Tether Line | 1 |
K | Ground Anchor | 3 |
PREPARATION
Before beginning assembly or operation of product, make sure all parts are
present. Compare parts with package contents list and diagram. If any part is
missing or damaged, do not attempt to assemble, install or operate the
product. Contact Customer Care for replacement parts.
• Estimated assembly time: 10 minutes
• Tools Required for Assembly: knife
OPERATION INSTRUCTIONS
Step 1. Remove assembled fountain from packaging and connect pump to
floating attachment assembly.
NOTE : For 1/4 HP, use the coupler to connect the pump.
Step 2. Choose a fountain head for the desired water effect, and assemble
your choice.
NOTE : For 1/4 HP, use the nozzle adapter.
Step 3. Connect the light to the cord (Part I) by pushing the plug into
the light socket until it is firmly seated. Hand tighten the nut from the plug
to the socket.
Step 4. Connect the cord for LED light to the sensor by pushing the plug
into the sensor socket until it is firmly seated. Hand tighten the nut from
the plug to the socket.
Step 5. Connect the sensor to the transformer by pushing the plug into
the transformer socket until it is firmly seated. Hand tighten the nut from
the plug to the socket.
Step 6. Use a knife to cut 3 pieces of tether Line, line length depends
on your lake size, attach one side of each line to one of the three loops.
Step 7. Place the fountain into the water and tether it with supplied
line and ground anchors into desired location.
Step 8. Plug pump and transformer into GFCI rated outlet.
Step 9. This floating fountain uses a dusk to dawn sensor. At night, the
lights will automatically turn on; at sunrise, the lights will automatically
turn off. Make sure the sensor is not covered by dirt or debris.
PUMP PERFORMANCE
Pump Specifications
Max Flow Rate
2300 GPH at 0 ft. height
Power Consumption
130 watts / 1.5 amps
Pump Specifications
Max Flow Rate
5000 GPH at 0 ft. height
Power Consumption
230 watts / 2.5 amps
MAINTENANCE
To maximize the performance of the floating fountain, periodically disassemble to clean dirt and debris. When you notice a reduced flow from the fountain, this is a good indicator that it is time to clean the fountain.
CLEANING THE UNIT
Step 1. Before cleaning, always disconnect from the power source and
remove the floating fountain from the water.
Step 2. Remove nozzle from the fountain and clean in warm, soapy water.
Step 3. Clean lights with a soft brush and non abrasive
cleaner.
CLEANING THE PUMP
Step 1: Before cleaning, always disconnect the pump from the power source
and remove the inlet screen.
Step 2: Remove the impeller housing to expose the impeller assembly.
Step 3: Remove the impeller assembly by gently pulling on the impeller
blades.
NOTE : This pump uses a very strong magnet. To protect your fingers from
potential injury, use caution when removing or inserting the impeller.
Step 4: Use a soft cloth or brush and warm water to clean the impeller
and the inside of the impeller and rotor housing.
Step 5: Reassemble all pump parts.
Step 6. Reassemble all parts making sure to fasten all interior electrical cords safely. Place the fountain into the water, and connect the fountain into a properly grounded electrical outlet.
TROUBLESHOOTING
IF THE FOUNTAIN FAILS TO OPERATE:
- Check to make sure the power cord is plugged in and the pump is getting power.
- Check the fountain nozzle for kinks or obstructions.
- Remove the inlet screen and/or pump cover of pump, and impeller housing to expose the impeller. Turn the impeller to ensure that it is not broken or jammed. Also check to make sure that the ceramic shaft or bearings are not broken.
IF THE PERFORMANCE OF THE PUMP IS NOT SATISFACTORY OR THE FOUNTAIN DOES NOT FLOW EVENLY:
- Check to make sure the pump is completely submerged in water.
- Check to make sure the impeller and the housing are clean.
- Check to make sure the fountain nozzle is clean.
IF THE LIGHTS DO NOT TURN ON
- Check to make sure the transformer is plug in power outlet.
- If transformer is plug in power oulet, check that lights are getting power by testing another appliance in the same power outlet.
- The light is designed to turn on when it gets dark, and turn off when it gets light. To activate the light during daylight hours, cover the sensor. If lights do not turn off during daytime, check sensor. Make sure the sensor faces up and is not covered by dirt or debris.
- Check to see if the power cord is not cut or damaged.
For more information on product maintenance and maintenance videos, visit www.thepondboss.net
REPLACEMENT PARTS
52595
B| Trumpet Nozzle
C| Single Tier Nozzle
D| 3 Tier Nozzle
E| Nozzle adapter
F| Coupler
G| Transformer
H| Sensor
I| Pump with cord for LED light
J| Tether Line
K| Ground Anchor
L| Led light set
M| Light cord Extension
N| Float
O| bolt
P| Washer 1
Q| Washer 2
R| Screw 1
S| Fountain Support
T| Nut
U| Adapter
V| Locking ring
W| Screw 2
X| Screen
Y| Impeller housing
Z| Impeller Assembly
A1| O-ring
52621
B| Trumpet Nozzle
C| Single Tier Nozzle
D| 3 Tier Nozzle
E| Transformer
F| Sensor
G| Pump with cord for LED light
H| Tether Line
I| Ground Anchor
J| Led light set
K| Light cord Extension
L| Float bolt
M| 1/3 float attachment
N| Washer 1
O| Screw 1
P| Fountain Support
Q| Adapter
R| Locking ring
S| Screw 2
T| Screen
U| Impeller housing
V| Impeller Assembly
W| O-ring
3 YEAR LIMITED WARRANTY
LIMITED WARRANTY
All pumps and electrical products are warranted to the user against defective
material and workmanship, under normal working conditions. This warranty
period begins on the date of purchase by the original purchaser.
APPLICATION
The warranty covers only properly installed and maintained units. Any damage
or modification to the cord or to the unit will terminate the warranty. Pump
warranty is limited to applications pumping fresh water in a pond or fountain
only. Other liquid applications or extreme temperature uses must be approved
in writing by the manufacturer. Receipt and product date code are required for
warranty claims.
WARRANTY CLAIM
Warranty claims must be made by calling Customer Care (at 1-888-755-6750). If the item is determined to be defective, you will be given authorization to return the defective part(s), freight pre-paid, along with proof of purchase.
DISPOSITION
The manufacturer will make a good faith effort for prompt disposition
regarding all warranty claims. Returned product will be inspected to determine
cause of failure before warranty is applied. Warranty does not cover any costs
associated with the shipping, handling, installation or removal of products or
parts subject to this warranty. For products damaged in transit, a claim
should be filed with the carrier.
DISCLAIMER
Any oral statements made about the product by the seller, the manufacturer,
the representatives, or any other parties do not constitute warranties, should
not be relied upon by the user, and are not part of the contract for sale. The
seller’s and manufacturer’s only obligation, and buyer’s only remedy shall be
for the manufacturer to either replace and/or repair at the manufacturer’s
sole discretion, the product as described above. Neither seller nor the
manufacturer shall be liable for injury, loss or damages for lost profits,
lost sales, injury to person or property, or any other incidental or
consequential loss arising from any cause whatsoever, no matter whether based
upon warranty, contract, negligence or other misuse, and the buyer and user
agree that no other remedy shall be available to them. Before using, the buyer
and user shall determine the suitability of the product for the intended use,
and assume all risk and liability whatsoever in connection therewith. The
warranty and remedy described in this limited warranty is an exclusive
warranty and remedy in lieu of any other warranty or remedy expressed or
implied. All other warranties and remedies are hereby expressly excluded,
including but not limited to any implied warranty or merchantability of
fitness for any particular purpose. This warranty gives the buyer and user
specific legal rights, and buyer and user may also have other rights which
vary from state to state. Some states do not allow exclusioinis or limitations
of incidental or consequential damages, so the above limitations or exclusions
may not apply to you.
VISIT WWW.THEPONDBOSS.NET FOR PRODUCT INFORMATION AND TIPS.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>