Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub Owner’s Manual

June 6, 2024
Bestway

Bestway - logowww.bestwaycorp.com
SaluSpa™
Owner’s Manual

Visit Bestway YouTube Channel
FOR INSTRUCTION VIDEOS
PLEASE VISIT
www.bestwaycorp.com/support

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - qr
codehttp://www.bestwaycorp.com

WARNING

IMPORTANT SAFETY INSTRUCTIONS

When using this electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS.
WARNING — To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. The aware connector is provided on this unit to connect a minimum 6 AWG (133 mm) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.

DANGER — Risk of injury.
a) Replace damaged cord immediately
b) Do not bury cord.
c) Connect to a grounded, grounding-type receptacle only.

WARNING —This product is provided with a ground-fault circuit interrupter integrated with the power plug at the end of the cord. The GFCI must be tested before each use. With the product operating, push the test button on the GFCI and the product should not operate. Push the reset button on the GFCI and the product should now operate normally. When the product fails to operate in this manner, there is a ground current flowing indicating the possibility of an electrical shock. Disconnect the power until the fault has been identified and corrected.

DANGER — Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times.

DANGER — Risk of Injury. The suction fittings in this spa are sized to match the specific water flow created by the pump. Should the need arise to replace the suction fittings or the pump, be sure that the flow rates are compatible Never operate the spa if the suction fittings are broken or missing? Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting.

DANGER — Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum of 6 AWG (13.3 mm2) solid copper conductors to the wire connector on the terminal box that is provided for this purpose.

DANGER — Risk of Electric Shock. Do not pert* any electric appliance, such as a light, telephone, radio, or television, within 5 feet (1.5 m) of a spa.

WARNING —To reduce the risk of injury:
a) The water in a spa should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C (104°F) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when the spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 38t (100*F).
c) Before entering a spa, the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure; circulatory system problems or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affect heart rate, blood pressure, and circulation.
WARNING: TO AVOID ELECTRIC SHOCK DO NOT USE THE SPA WHEN IT IS RAINING. WARNING: Water attracts children: Always attach a spa cover after each use.
WARNING: TO REDUCE THE RISK OF INJURY: Never add water that is higher than 40°C (104°F) into the Spa. CONSULT YOUR PHYSICIAN FOR RECOMMENDATIONS.
CAUTION: The spa should not be set up or left out in temperatures lower than 4°C (40″F). CAUTION: Do not use the spa alone.
CAUTION: Always enter and exit the spa slowly and cautiously. Wet surfaces are slippery.
CAUTION: To avoid damage to the pump, the spa must never be operated unless the spa is filled with water. CAUTION: Immediately leave spa if the user feels uncomfortable or sleepy.
NOTE: Please examine equipment before use. Notify Bestwaf at the customer service address listed on this manual for any damaged or missing parts at the time of purchase. Verify that the equipment components represent the model that you had intended to purchase. _

SAVE THESE INSTRUCTIONS

WARNING: CHILDREN SHOULD NOT USE SPAS OR HOT TUBS WITHOUT ADULT SUPERVISION. WARPING: DO NOT USE SPAS OR HOT TUBS UNLESS ALL SUCTION GUARDS ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.
WARPING: PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USINGASPAOR A HOT TUB.
WARPING: PEOPLE WITH INFECTIOUS DISEASES SHOULD NOT USE A SPA OR HOT TUB. WARNING: TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR DOTING THE SPA OR HOT TUB. WARPING: DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING THE USE OF A SPA OR HOT TUB TO AVOID UNCONSCIOUSNESS AND POSSIBLE DROWNING. WARNING: PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA OR HOT TUB.
WARNING: WATER TEMPERATURE IN EXCESS OF 38°C (100W) CAN BE INJURIOUS TO YOUR HEALTH. WARPING: BEFORE ENTERING THE SPA OR HOT TUB, MEASURE THE WATER TEMPERATURE WITH AN ACCURATE THERMOMETER.
WARNING: DO NOT USE A SPA OR HOT TUB IMMEDIATELY FOLLOWING STRENUOUS EXERCISE.
WARNING: PROLONGED IMMERSION IN A SPA OR HOT TUSCAN BE INJURIOUS TO YOUR HEALTH.
WARNING: DO NOT PERMIT ELECTRIC APPLIANCES (SUCH AS A LIGHT, TELEPHONE, RADIO, OR TELEVISION) WITHIN 1.5M OF THIS OR HOT TUB.
CAUTION: MAINTAIN WATER CHEMISTRY IN ACCORDANCE WITH/MTH MANUFACTURER’S INSTRUCTIONS.

ASSEMBLY: THE PROVIDED WARNING LABEL

WARNING

REDUCE THE RISK OF ELECTROCUTION

  1. NEVER PLACE AN ELECTRIC APPLIANCE WITHIN 5 FEET OF THE SPA.
    REDUCE THE RISK OF CHILD DROWNING

  2. SUPERVISE CHILDREN AT ALL TIMES.

  3. ATTACH SPA COVER AFTER EACH USE TO

REDUCE THE RISK OF OVERHEATING

  1. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR HEALTH, OR UNDER MEDICAL CARE.
  2. EXIT IMMEDIATELY IF UNCOMFORTABLE. DIZZY, OR SLEEPY. SPA HEAT CAN CAUSE HYPERTHERMIA AND UNCONSCIOUSNESS.
  3. SPA HEAT IN CONJUNCTION WITH ALCOHOL, DRUGS, OR MEDICATION CAN CAUSE UNCONSCIOUSNESS.

WHEN PREGNANT , SOAKING IN HOT WATER FOR LONG PERIODS, AN HARMS YOUR FETUS. MEASURE WATER TEMPERATURE BEFORE ENTERING.

  1. DO NOT ENTER THE SPA IF WATER IS HOTTER THAN 1000F (38°C)
  2. DO NOT STAY IN THE SPA FOR LONGER THAN 10 MINUTES.

NOTE: The warning label must be posted near your spa in a readable position during using your spa.

  1. Take out the warning label from the accessory kit.
  2. Carefully peel the warning label.
  3. Affix the warning label.
    To order the to warn label, please contact your local Bestway Customer Service.

WARNING FOR ELECTRIC AIR PUMP (For Palm Springs HydroJet)

  1. Motor run time should not exceed 20 minutes. The operator should allow the motor to cool for 10 minutes between uses.
  2. This appliance has a polarized plug (one blade is wider than the other) To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way, if the plug does not fit fully in the outlet, reserve the plug, if it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
  3. For adult use only.
  4. Inflation and deflation ports should be kept unobstructed during use.
  5. The product must be stored in a dry location.
  6. Please comply with local disposal codes when discarding the pump.

CAUTION: TO AVOID THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE YOURSELF TO WATER OR RAIN. FOR INDOOR USE ONLY. FOR HOUSEHOLD USE ONLY.

IMPORTANT! To reach 40°C (104°F) the heating duration required is based on the starting water temperature and ambient temperature. The data below is purely for reference. To display the current water temperature, run the filter system for at least a minute.

Ambient Temperature

| Water Temperature| Set Temperature|

Heating Duration

---|---|---|---
10°C(50°F)| 10°C(50°F)| 40°C(104°F)| 32 h
15°C(59°F)| 15°C(59°F)| 40°C(104°F)| 26 h
20°C(68°F)| 20°C(68°F)| 40°C(104°F)| 20 h
25°C(77°F)| 25°C(77°F)| 40°C(104°F)| 14 h
30°C(86°F)| 30°C(86°F)| 40°C(104°F)| 9 h

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
2
Be sure to cover the spa with the spa cover whenever the heating function is activated. Leaving the spa uncovered will increase the heating duration required. Please do not use the spa when the ambient temperature is lower than 4°C (39°F ).

SAVE THESE INSTRUCTIONS

SPECIFICATION

| HYDROJET|

HYDROJET PRO

---|---|---
Power Rate| 110-120V AC,12A at 20°C| 110-120V AC,12A at 20°C
Heat Element Power| 11.3A at 68°F| 11.3A at 68°F
Filter Pump Power| 0.7A| 0.7A
Massage Tube Power| –| 6.5A
Jet Pump Power| 12A| 12A
Soft Water System| 1 A| 1 A

Pump Test
GFCI Test
Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
3

  1. Plug the GFCI into a power outlet.
  2. Press the reset button, the indicator turns red.
  3. Press the test button, the indicator turns off.
  4. Press the reset button again, the indicator turns red.
  5. Press the “On/Off” button for 2 seconds, your pump is ready for us

WARNING: The GFCI plug must be tested before each use to avoid shock.
WARNING: Before inserting the plug into a power outlet, make sure the power outlet is suitable for the pump.

ASSEMBLY

NOTE: Only the Hydro-Jet Pro SPA has the massage system button. When inflating, you will notice that air will be expelled from the area where the air hose connects to the pump, this is normal and prevents damage due to over- inflation.
NOTE: Do not use an air compressor to inflate the pool.
NOTE: Do not drag the pool on rough ground as this may cause damage to the pool liner.
NOTE: Inflation time is for reference only.
NOTE: The pressure gauge is for inflation purposes only, and the value shown by the pressure gauge is just for reference. It should not be used as a precision instrument.
Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
5Air Valve Check Always check the air valve carefully before inflation to ensure there is not an air leak. If the air valve is loose, use the provided wrench to fasten the air valve following these steps: With one hand, hold the backside of the air valve from the inner side of the sea wall and turn the wrench clockwise.

NOTE:

  1. Do not overtighten.
  2. Do not adjust the air valve connector when the spa is in use.

Please refer to the provided Instructional page
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37°C (98.6°F). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include failure to perceive heat; failure to recognize the need to exit spa or hot tub; unawareness of impending hazard; fetal damage in pregnant women; physical inability to exit the spa or hot tub; and unconsciousness resulting in the danger of drowning.
WARNING: THE USE OF ALCOHOL OR DRUGS CAN GREATLY INCREASE THE RISK OF FATAL HYPERTHERMIA IN HOT TUBS AND SPAS.
WARNING: WATER TEMPERATURE IN EXCESS OF 38°C (100°F) CAN BE INJURIOUS TO YOUR HEALTH.

OPERATION

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
7Bestway 1054124USX20
Saluspa Miami Inflatable Hot Tub - fig 8

3. Adjustment of Jet Nozzle.
Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
9

Lock Unlock Button
The pump has a 5-minute auto-lock. The LED light MI dim out Wien the pump is locked (no function is activated).To lock or unlock the pump, place a finger over the lock/unlock button for 3 seconds.

Lay-Z-Massage System Button (For Hydro-Jet Pro)
Use this button to activate the massage system, Mich has a 30-minute auto- shutoff feature. The light above the Massage system button displays red when activated.

IMPORTANT: Do not run the Massage system Menthe cover is attached. Air can accumulate inside the spa and cause irreparable damage to the cover and bodily harm.
NOTE: Heat and massage system vicirk together to create an ‘arm massage experience.
HydroJet System Button
This button turns the Vkat e r pump on and off.
The light above the HydroJet system button displays red ‘then activated.
Note: The system will shut off automatically after 1 hour.
Note: Do not dry run the H ydroJet System.
Heat Button
Use this button to activate the heating system. When the light above the heat button is red, the heating system is activated. When the light is green, the voter is at the set temperature and the heating system is at rest.
NOTE: If the heating system is activated, the filtration system will automatically start.
NOTE: After turning off the heating system, the filtration system will continue to operate.
Water Filter Button
This button turns the filter pump on and off.
The light above the Water Filter Button displays red Wien activated.
NOTE: The built-in hard water treatment function works automatically.
Power-Saving Timer Button This is a newly added funding, designed to help avoid wasting power by setting the time and duration of the heating cycle for the spa.
This ‘say you can enjoy your spa at the time you desire, Without needing to leave the heater on at all times.

STEP 1 : Set the heating duration

  1. Press the button unit the LED starts to lash.
  2. Press the or buttons to adjust the heating duration (From 1-48 hours).
  3. Press the button again to confirm the heating duration.

STEP 2: Set the number of hours FROM NOW Wien the heater WV to activate

  1. After setting the heating duration, the LED starts to flash.
  2. Press the or buttons to adjust the hours until the time of activation (From 0-99 hours).
  3. Press the button again or simply touch nothing for 10 seconds to confirm the setting.

The LED will light steadily, and the countdown to heater activation will begin.

To modify the timer setting Press the ‘w button and use the
Cancel the setting: Press the button for 2 seconds.
NOTE: After setting, the screen lashes the current temperature and time alternately.
NOTE: Timer an Etrue nt (amount of time w it the heater ON) ma” he set from 1 to 4 hours; reservation time adiListm ent (the number of hours right-in the heater ‘, AD begin to function) may be set from 0 to 99 hours. If the timer is set at 0 hours, it means the Timer Pin di On is not: set. 0 or button not set.

Note that the timer is a one-time peruse -the user sets the duration of the heating cycle, and how many hours tom now the heating cycle begins. The timer does NOT repeat mitt reset.

Celsius/Fahrenheit Toggle
The temperature can be displayed in either Celsius or Fahrenheit.

Temperature Adjustment Buttons
Pressing the Temperature Increase or Decrease buttons will cause the LED to lash. When it is flashing you can adjust to the desired temperature setting. If you hold these buttons down, the values will rapidly increase or decrease. The new desired temperature setting will remain on the LED display for 3 seconds to confirm the new value.
NOTE: The default temperature is 35°C (951).
NOTE: Tendierature adjustment ranges from 20°C (831) to 40″C (1041).
Power-Saving Timer LED
This LED flashing means you are setting the heating duration. The light WI is on Wien the heating function starts to the wort.
This LED flashing means you are setting the number of hours FROM NOW when the heater will activate. When the light is on, the Power-Saving Timer function is set. Only Button
Press this button for 2 seconds to activate the control panel buttons end the light turns green. Press this button for 2 seconds to turn off at currently activated funding.
LED Display.
Once powered up, the LED displays the current water temperature automatically. After 72 hours of filtration (without using the power saving timer function), the pump will hibernate and flash ‘End with the current water temp geniture. When the pump is hibernating both the heating and water Alter renditions are disabled. To re-active the pump press the lodutiodc button for 3 seconds.

NOT: The water he et rate may change in the below conditions

  • When the outdoor temperature is below 15°C (591).
  • If the cover is not In the position when the heating function is activated.

NOTE: To cosplay the current water temperature, run the filter system for at least a minute. The water temperature as tested by an extern thermometer may vary from the temperature as displayed on the spa panel due to the differing positions of the measurement devices.

Causes

| Reasons|

Solutions

---|---|---
| The water flow sensors work without pressing the filter or heat button.| 1. The water low sensor lags didn’t fall back into the correct position.
2. The water Ice/sensors are broken.| 1. Unplug the pump, strick e the side of the pump firmly(but not violently), and plug
2. it back in. Contact your local Best may Aftersales Service Center for instructions.
| After stating during the functions of Mering or/and heating, the waler few sensors do not detect water flow.| 1. You forgot to remove the 2 stopper caps from inside the Me pod.
2. The titer cartridges are dirty.
3. Activate the filter or heat system and put your hand in front of the outlet pee Inside the pool to check if you can feel the water. flowing out.
a. I no water flows out the water pump is broken.
b. Water flies out but the alarm rm appears, the water flow sensors are broken.–| 1. Remove the two stopper caps before starling the healing system Refer to the Assembly section in the Users Manual
2. Remove the fitter set from inside the pool and push the filler or heat button. If no alarm appears, clean or change the filter cartridges and re- install the filler set Inside the pool.
3. Contact your local Best ay Aftersales Service Center for instructions.
| The pump’s thermometer   reads   the water temperature being

4°C (4)–F).

| 1. The water temperature is lower than 4°C (417F).
2. If the veer temperature is higher than 7°C (44.61), the pump’s thermometer is broken.| 1. The spa is not designed to operate with water temperatures lower Mandl% (401). Unplug the pump and IA restart the pump when the water temperature reaches

6°C (437)-
2. Contact your local Bestway Aftersales Service Center for instructions.

|  The pump’s thermometer reads the water temperature over 48T (119’T).| 1. The voter temperature is over 48°C (1191).
2. If the veer temperature is lover than 45°C (1131), the pump’s thermometer is broken.| 1. The spa is not designed to operate with voter temperatures (more real than  40°C a 041). Unplug the pump and only re-start the tie pump Wien the water temperature reaches 33°C (1001) or love.
2. Cortad your local Seaway Aftersales Service Center for instructions.
| The pump’s  thermometer
connections have issues.| 1. The cump’strermometer connectors are not working properly.
2. The pump’s thermometer is broken.| Contact your local Bestway Aftersales Service Center for instructions.
| The thermal cut-out cut-off.| 1.  The alibied temperature is over 50t (1221) or the pump is directly under the sunshine.
2.  The thermal o•out is broken.| 1.   Unplug the pump, and oil plug in a dry, cool, when the water temperature reaches 346C, (93.

2.   Contact your local Sedway Aftersales service parts. Only re-stat the pump or lover. to get instructions.

| (2191) F me tau?!| The fuse S disconnected.| Contact your local Bestway Aftersales Semite Center for instructions.
| Signal line disconnected| The signal lie between the control panel and the power board is not well connected.| Contact your local Bestway Aftersales Service Center for instructions.

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
10

MAINTENANCE

NOTE: Your spa will require additional air to be added from time to time. Changes in temperature from day to night will change the pressure in the spa and may cause a certain amount of deflation. Please follow the Assembly instructions and drain the spa before inflating to the accurate pressure needed.

CAUTION: YOU MUST ENSURE THE PUMP IS UNPLUGGED BEFORE BEGINNING SPA MAINTENANCE.

Electric Air Pump Maintenance

  1. Use a dry cloth to gently clean all surfaces.
  2. Store in a cool; dry place and out of children’s reach. Filter Cartridge Maintenance

NOTE: To ensure your spa water stays clean, check and clean your filter cartridges every day – follow the steps below.

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
12

NOTE: We recommend changing your filter cartridges every week.

Water Maintenance
To keep your SPA water clean, a chemical balance is necessary. Merely cleaning the filter cartridge is not sufficient for this purpose. Please refer to either of the below recommendations: Using chemical tablets (not included)
(Reference: Trichlorinafed isocyanuric acid 3-6g)

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
13Using chemical liquid (not included)
(Refer to the instructions of the liquid chemicals purchased)
Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
14

NOTE: We recommend you take a shower before using your SaluSpa. Cosmetic products, lotions, and other residues on the skin can quickly degrade water quality.
NOTE: Remove the chemical dispenser from the spa when the spa is in use.

IMPORTANT: After performing chemical maintenance and before using the spa, use a test kit (not included) to test the water chemistry. We recommend maintaining your water as per the table below.

pH Total Alkalinity Free Chlorine
7.4-7.6 80-120ppm _      2-4ppm

NOTE: Damage resulting from chemical imbalance is not covered by the warranty. Pool chemicals are potentially toxic and should be handled with care. There are serious health risks from chemical vapors and the incorrect labeling and storage of chemical containers. Please consult your local pool supply retailer for more information about chemical maintenance. Pay dose attention to the chemical manufacturer’s instructions. Spa damage resulting from the misuse of chemicals and mismanagement of spa water is not covered by the warranty.

Jet Nozzle Maintenance

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
15

  1. Twist until hearing a “click” sound, and pull out the Jet Nozzle to clean the debris.
  2. Insert and twist clockwise to put it back.

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
15

Draining the Spa

NOTE: Drawings for illustration purposes only. May not reflect the actual product. Not to scale.

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
16Bestway 1054124USX20
Saluspa Miami Inflatable Hot Tub - fig 17Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub -
fig 18

Cleaning the spa Detergent residues and dissolved solids from bathing suits and chemicals may build up on the spa walls. Use soap and water to clean the walls and rinse thoroughly.
NOTE: DO NOT use hard brushes or abrasive cleaners.
DEFLATION

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
19

Bestway 1054124USX20 Saluspa Miami Inflatable Hot Tub - fig
20

Spa Repair

For Spa inflatable cover

If the spa is torn or punctured, use the provided heavy-duty repair patch.

  1. Clean area to be repaired.
  2. Carefully peel patch.
  3. Press patch over the area to be repaired.
  4. Wait 30 minutes before inflation.

For Spa Liner

if the spa is torn or punctured, use the provided PVC repair patch and glue (not included) following these steps:

  1. Clean and dry the area to be repaired.
  2. Cut the provided PVC patch to the appropriate size.
  3. Use glue (not included) to coat one side of the newly cut patch. Make sure the glue is evenly distributed.
  4. Wait for 30 seconds and then pace the cut patch with glue over the damaged area.
  5. Smooth out any bubbles of air that may be trapped underneath, and press firmly for two minutes.
  6. Wait 30 minutes before inflation.
  7. The product is once again ready for use. Repeat this process should further leaks occur.

SaluSpa Storage
Before storing, make sure the spa and pump are completely dry. This is essential to extend the life of the spa. We recommend using the pump to blow dry the spa, pump, and pipes. Remove the filter sets and discard the used filter cartridges. Re-attach the two stopper caps onto the spa’s inlet and outlet valves. It is recommended you store the spa in its original package in a warm dry place.

NOTE: Plastic becomes brittle and susceptible to breaking when exposed to sub-zero temperatures. Freezing can severely damage the spa. Improper winterization of your spa can void your warranty.

TROUBLESHOOTING

Bestway strives to provide the most trouble-free spas on the market. If you experience any problems whatsoever, do not hesitate to contact Bestway or your authorized dealer. Here are some helpful tips to help you to diagnose and rectify some common sources of trouble.

Problems| Probable Causes|

Solutions

---|---|---
The pump does not operate| – Power failure

– Power circuits broken

| – Check power source
– Contact your local Betray Aftersales Service Center for institutions
The pump does nit neat properly| – Temperature set too low
– Dirty filter carrick
– The thermal cut-out Ws off
– The heating element has failed| – Set the heat® system to a number temperature (refer to Pump Operation section)
· Clearvreplace the Filter Cartridge (refer to Filter Cartridge Cleaning and Replacement section)
– Re-Start wrier) the temperature is below 38°C (1 00•F)
– Contact your local Bestway Aftersales Service Center for instructions
massage System Wes not work| -Air Pump is overeating – The massage system stops atomically
-Air pump is tr oken| · Unplug my pump and wait two hours until the pump has cooled Insert the plug and press the massage system Dillon – Press the massage system button to reactivate
– Contact your local Bestway Aftersales Service Center for instructions
Pump adapters are not level with the spa adapters| – One characteristic of PVC is that it
changes shape. lynch is normal| – Elevate tie pump Kenwood or anoMer type of insured material to bring the pumps adapters level with the spas adopters
Spa pool leakage| – Spa is torn or punctured
· Air valve is loose| – Use provided repair paten
Using soapy water, coder the ar-valve to check airts leaking, if so, use the provided wrench to fasten the air valve following the state of the SPA.
2 With one at, hold de backside of the fie air valve from the inner side of the sea wall and tum the wrench clockwise.
water is not clean| ·  InsUficient Illtenng time
·  Duty Filter Cartridge – improper water maintenance| – Increase file trationerne
– CleaMeplace the Filter Cartridge (refer to Alter Cartridge Cleaning and Replacement section)
– Refer to the chemical manufacturers instructions
GFCI test faded| There is detection in your spa| Contact your local Bestway Aftersales Service Center and return the SPA
Hydrate System does network| – Water plop is overheating
· Water pimp is broken| – Unplug the pump and wait fa two hours and the pump

has coded. Plugin and try again

– Contact your local Bestway Aftersales Service Center for instructions

The Control panel not working| . The CO MO( parcel has an auto-lock. whit his activated alter 5 minutes or inactivity The LEO cosplay has one icon n if the lock icon is ring light. the contra panel is lotted.
– Control panel is not actuated.| . To Murdock the control panel, press the to bunion for 3 seconds if the control pare) will not unlock, restart the pump — unplug and plug-In me pimp

– Press the off button for 2 seconds

if the problem persists, please contact your local Bestway Aftersales Senwce Center for instructions.

What kind of chemicals should be used for water maintenance,| Please consult your Kcal chemical supplier for information about chemical m a rename. Pa, close attention to the chemical manufacturers instructions
water leaks from the adapters between the ump and spa| insert the three stopper caps onto the spa’s ports to prevent water from escaping and disconnect the pump. Check and make sure the seas are placed correctly inside the pimp adapters. If the seas are missing or not installed correctly, please contact your local Bestway Aftersales Service Center for instructions. If the seals are correctly in place, reconnect the pump to the spa and hand-taken the adapters.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals