ALORAIR HD55 Basement Crawl Space Dehumidifier Instruction Manual
- June 6, 2024
- Alorair
Table of Contents
- ALORAIR HD55 Basement Crawl Space Dehumidifier
- Warranty Registration
- Safety Notes
- Installation
- Remote Control Instructions
- Operating Instructions
- Maintenance
- Troubleshooting
- Sentinel HD55 Diagram
- Limited Warranty
- Sentinel HD55 Spare Parts
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ALORAIR HD55 Basement Crawl Space Dehumidifier
Warranty Registration
Congratulations on purchasing a new Sentinel Dehumidifier. Your new
dehumidifier comes with an extensive warranty plan. To register, simply fill
out and return the warranty form provided in the dehumidfier box.
Be sure to note your dehumidifier serial number as you will need it for
registration.
Safety Notes
- The Sentinel Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances). If non-grounded wiring is used, all I iability reverts to owner and the warranty is voided .
- Sentinel Dehumidifiers should only be maintained and repaired by a qualified technician .
- Sentinel Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level. Operating the unit in any other orientation could allow water to flood electrical components .
- Always unplug dehumidifier before moving .
- If there is a chance that water flooded the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting .
- To ensure proper operation, neither the inlet nor discharge should be positioned against a wall. The inlet requires a minimum of 12″ clearance and the discharge requires a minimum of 36″ clearance.
- The best option for proper diffusion of air throughout the room is to have the discharge blowing away from a wall and the inlet pulling air in parallel to a wall.
- Do not insert your fingers or any object into the inlet or discharge.
- All work on the dehumidifier should be done with the unit “off’ and unplugged.
- Do not use water to clean the exterior of the machine. To clean unit, unplug from power, then use a damp cloth to wipe exterior.
- Do not stand on the machine or use it as a device to hang clothes.
Identification
For future reference, write down the model, serial number, and date of
purchase for your dehumidifier. This is extremely helpful if you need to seek
assistance in the future. The data label on the side of your unit has the key
characteristics of your specific machine.
Model Number: Sentinel HD55
Serial Number: __ Date of Purchase: ____
For additional questions concerning your dehumidifier, the following options
are available:
• Contact your installing contractor
• E-mail: sales@alorair.com
Electrical Supply
Power Supply: 115 V, 60 Hz AC, Single Phase
Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp
WARNING 240 Volts AC may cause serious injury from electric shock.
To reduce risk of injury:
1. Disconnect electrical power before servicing .
2. Only plug unit into grounded electrical circuit .
3. Do not use an extension cord.
4. Do not use a plug adapter.
Principle of Operation
The Sentinel Series Dehumidifier utilizes its integral humidistat to monitor
the conditioned space. When the relative humidity goes above the selected set
point, the dehumidifier will energize. Air is drawn across an evaporator coil,
which is cooler than the dew point of air. This means moisture will condense
out of the air. The air is then reheated through the condenser coil and
distributed back into the room.
Installation
The area to be controlled should be sealed with a vapor barrier. If unit is installed in a crawlspace, all vents should be sealed.
WARNING Do not install your dehumidifier in a corrosive environment. Some liquid vapor barriers dry via “solvent evaporation”. Always make sure that barrier is completely dry and area is throughly ventilated before installing dehumidifier.
Step #1: Place dehumidifier on a level surface.
Do not place directly on vapor barrier. For example, use blocks, or pavers to
create a level surface.
Remote Control Instructions
Sentinel Dehumidifiers can be controlled using an optional remote accessory.The Sentinel Remote Control connects to your Sentinel Series Dehumidifier via a 25′ CAT 5 cable. The remote control contains an integrated sensor which gives you multiple options for remotely controlling your unit, in addition to monitoring the conditions surrounding the dehumidifier.
One application for the remote control is to install the dehumidifier in one room with the conditioned air ducted into a second room that contains the remote. For example, the dehumidifier could be installed in a laundry room and ducted into a living room. The remote would then be mounted in the living room so the remote sensor can control the humidity and provide easy controls for the user.
Another useful application for the remote control is if the dehumidifier is in area that’s difficult to access on a regular basis. For instance, if your dehumidifier is installed in your crawl space, the remote could be mounted in your living space or garage. This provides you with an easy way to monitor the dehumidifier.
-
On/Off (Power)Button ©
Press the on/off button and the machine will start running (one beep). Press the button again to the turn the machine off. -
Up Butt on • / Down Button “‘
Use the Up and Down arrow buttons to adjust the humidity level. -
Mode M
Use the Mode button to switch between dehumidification and a ducted application.
• The @ symbol on the display board indicates the sensor on the remote control is being utilized.
• The • symbol on the display board indicates the sensor on the dehumidifier is being utilized. -
Temperature T
Press the temperature button to display the current temperature on the screen. Press the button again to turn off the display. -
Continuous C
Press this button to switch the unit into continuous mode. cont. will appear on the display to indicate continuous mode. -
Drain Pump P
Use this button if the unit will not be in use for an extended period of time. Pressing the drain pump button will remove water from the pump reservoir, so the unit can be safely moved or stored. THIS FUNCTION IS ONLY AVAILABLE ON THE Sentinel HDi90 model.
NOTE: Symbols indicated above will only appear when the dehumidifier is powered on.
Operating Instructions
-
Start the Machine
Press the power key to turn the machine on. -
Adjust the Settings
Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%). -
Stop the Machine
Press the power key again and the machine will stop. Note the fan will continue to operate for 1 minute after the unit has turned off. NOTE: Do not disconnect the power cord to force unit to stop. Always use the power button. -
Water Drainage
During normal operation, the Sentinel HD55 will automatically drain by the force of gravity. If you want to move or store your machine, wait at least 10 minutes to allow the machine to completely defrost, then lean unit gently towards drain to ensure that it is completely drained.
Maintenance
WARNING Always unplug the unit before doing any maintenance.
Cleaning the machine body
Use a soft damp cloth to clean exterior of unit. Do not use any soap or
solvents.
Cleaning the filter
- Unplug the unit.
- Slide out the filter.
- Clean the filter mesh by vacuuming or washing with warm water (no soap or solvents).
- Be sure filter is completely dry before restarting unit.
Coil Maintenance
Once per year, clean the coils with an approved coil cleaner.
• Coil cleaner should be a self rinsing, foaming cleaner such as WEB® Coil
Cleaner.
Dehumidifier Storage
If the unit will be stored for an extended period of time, complete the
following steps:
- Turn off the unit and allow to dry_
- Wrap and secure the power cord.
- Cover the filter mesh.
- Store in a clean, dry space.
Ducted Applications
Ducting the dehumidifier allows the unit to be in one room while conditioning
an adjacent room.
The supply grille is designed for 6″ flex ducting. Be sure to secure the
ducting with tie wrap. Also, keep in mind that the supply ducting can be
screwed into an adapter if necessary.
Ducting lnsatallation
• Maximum length for ducting= 6′
Note: The supply duct adapter is standard on all units.
Troubleshooting
Sentinel HD55 Diagram
Back View
Limited Warranty
This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the original purchaser that this ALORAIR product is free from manufacturing defects in material or workmanship for the limited warranty period of:
Six (6) Month parts and labor. This includes the shipments charges for
replacement parts or unit.
One (1) year parts and labor. This does not include the shipment charge to
send the defective product back to be repaired or replaced.
Three (3) years parts and labor on Refrigeration System ONLY (Compressor,
Condenser, and evaporator). Transportation cost, not included.
Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and
evaporator). Transportation cost, not included.
This limited warranty is valid only on products purchased from the manufacturer or ALORAIR authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Alorair Solutions Inc will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact AL ORAi Rat 888-990-7 469 or support@alorair.com. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of ALORAIR.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or
workmanship encountered in normal household, commercial or noncommercial use
of this product and shall not cover the following:
- Damage occurs in uses for which this product was not intended for.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.
Sentinel HD55 Spare Parts
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>