sinope Smart Double Pole Thermostat TH1500ZB Installation Guide
- June 6, 2024
- sinope
Table of Contents
- INSTALL YOUR THERMOSTAT
- USER SETTINGS
- ADD YOUR THERMOSTAT TO THE GT130 GATEWAY AND NEVIWEB
- CONNECT YOUR THERMOSTAT TO A ZIGBEE COMPATIBLE SYSTEM
- DISCONNECT YOUR THERMOSTAT FROM A ZIGBEE COMPATIBLE SYSTEM
- SETTINGS THAT CAN BE MODIFIED ON THE DEVICE DIRECTLY
- TECHNICAL SPECIFICATIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TH1500ZB
Installation Guide
Smart Double
Pole Thermostat
zigbee 3.0
Warnings
The installation of this thermostat must be performed by a certified
electrician and comply with the national and local electrical codes and
regulations.
Make sure to turn off the heating circuit at the main electrical panel to
avoid any risk of electric shock.
INSTALL YOUR THERMOSTAT
-
Unlock and lift the thermostat cover.
-
Use the provided connectors to connect the load/line wires located on the back of the thermostat.
**** Make sure to firmly tighten the wire connectors for a secure connection. A loose connection can be a fire hazard. -
Use the screws to secure the thermostat to the electrical box.
. -
Replace the cover and lock.
-
Power up the thermostat.
USER SETTINGS
All the parameters of your thermostat can be programmed through the interface of your Zigbee-compatible gateway. However, if your thermostat is not connected to your gateway and you wish to change the temperature format or the control cycle, you need to:
Get the setpoint to its minimum and hold the↓ button for 10 seconds to access
the menu.
Press the ↓or↑ button to change the setting,
Press the ↓ and ↑buttons simultaneously to save and go to the next parameter.
Continue to press until the end of the list to exit the menu.
ADD YOUR THERMOSTAT TO THE GT130 GATEWAY AND NEVIWEB
- If you do not have an account yet, download the Neviweb app for iOS or Android to open an account and add your device.
- Tap the then select “Add Device”
- Follow the steps of the Installation Wizard
CONNECT YOUR THERMOSTAT TO A ZIGBEE COMPATIBLE SYSTEM
-
Initiate the connectivity session of your Zigbee compatible hub by referring to the device’s user guide.
-
Connect your thermostat to the network by pressing simultaneously on the ↑and↓ buttons.
On the thermostat display:
Flashes = Connecting
Remains lit = Connected
If the connectivity fails, the ****symbol will disappear from the display. Refer to our website to troubleshoot the unit. -
Connect all your thermostats the same way, by going to the next closest thermostat.
-
When all the thermostats are connected, close the connectivity session of your Zigbee compatible hub.
DISCONNECT YOUR THERMOSTAT FROM A ZIGBEE COMPATIBLE SYSTEM
To disconnect your thermostat from the Zigbee compatible hub, press the ↓and ↑buttons simultaneously for 10 seconds. The symbol will disappear from the display.
SETTINGS THAT CAN BE MODIFIED ON THE DEVICE DIRECTLY
| Name| Parameters & settings| Display
---|---|---|---
1| Load| Load power
0 W to 4155 W [2]|
2| Temp| Temperature format
°C or °F [Default °C]|
3| Min| Minimum setpoint
5 °C to 36 °C [Default. 5 °C]|
4| Max| Maximum setpoint
5 °C to 36 °C [Default: 36 °C]|
1 ) Load power
Reading of the load power connected to the thermostat, featured in watts.
TECHNICAL SPECIFICATIONS
Operating voltage: 120 / 208 / 240 / 277 Vac, 50 / 60 Hz
Maximum load:
1800 W @ 120 V / 15 A
3120 W @ 208 V / 15 A
3600 W @ 240 V / 15 A
4155 W @ 277 V / 15 A
Setpoint range: 5 °C to 36 °C (41 °F to 96 °F)
Display range: 0 °C to 50 °C (32 °F to 99 °F)
Resolution : ± 0.5 °C (± 1 °F)
Storage: – 20 °C to 50 °C (-4 °F to 122 °F)
Operation: 0 °C to 50 °C (32 °F to 122 °F)
Zigbee 3.0 profile
Frequency: 2.4 GHz
Transmission power: +20 dBm
Receiver sensitivity: -108 dBm
Transmitter Module IC : 22394-ZBM1501 / FCC ID:2AK2T-ZBM1501
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device does not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of
the device.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy, and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment OFF and
ON, the user is encouraged to try to correct the interference by one or more
of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between
the equipment and receiver. Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected. Consult the dealer or
an experienced radio/TV technician for help.
3-year limited warranty
SINOPÉ TECHNOLOGIES INC. warrants the components of their products against
defects in material and workmanship for a 3 year period from the date of
purchase, under normal use and service, when proof of purchase of such is
provided to the manufacturer. This warranty does not cover any transportation
costs that may be incurred by the consumer. Nor does it cover a product
subjected to misuse or accidental damage. The obligation of SINOPÉ
TECHNOLOGIES INC., under the terms of this warranty, will be to supply a new
unit and this releases the manufacturer from paying the installation costs or
other secondary charges linked to replacing the unit or the components.
For more information, visit our website: www.sinopetech.com