Globalsources CF-818 Infrared Forehead Thermometer Instructions
- June 6, 2024
- globalsources
Table of Contents
Globalsources CF-818 Infrared Forehead Thermometer Instructions
Name and function of each component
Instructions
Change-overbutton
left and right Change-over button can switch the body temperature measurement mode and the object surface temperature measurement mode.
Setting button
Long press the setting button for 2 seconds to switch function settings.
F1 :Switch℃/℉, press “+”button switch to℃, press “-”button switch to℉.
F2 :Alarm temperature for body temperature measurement setting, press
“+”button to turn up the alarm temperature, press “-”button to turn down the
alarm temperature.
F3 :Temperature compensation adjustment, when the season or the
environment changes, it is necessary to check and debug the forehead
thermometer, press the “+” button to increase 0.1℃ (0.1℉), press the “-”
button to decrease 0.1℃ (0.1℉).
F4 : Sound Toggle, press“+” to turn on the sound toggle and press“-”to
turn off the sound toggle.
Read memory value
Press the plus button or the minus button to view the memory test value. In
total, 32groups of measurement data can be viewed. Press the measurement
button to exit the memory interface.
Temperature measurement
-
Align the Detection lens1-5cm from the forehead
Note: holding the body for a long time may cause the detector to read higher ambient temperature, so the test result may be lower than the actual value. It is recommended to place the product in the normal temperature environment when not testing.
Please try to keep still during the test. -
Press the measurement button
The measurement will be completed within 1 second and a “Di” sound will be made after completing the test.
Check body temperature
Toggle the Change-over button and switch it to the left to set body temperature measurement mode. Lo characters is displayed when the measured value is below 32 ℃and three “Di” sounds will be made after completing the test.
The green color is displayed within the measured value of 32.0-37.2℃ and a
“Di” sounds will be made after completing the test.
The yellow color is displayed within the measured value of 37.3-37.9℃ and a
“Di” sounds will be made after completing the test.
The red color is displayed within the measured value of 38.0-42.5℃ and continuous “Di”alarm sounds will be made after completing the test. HI characters is displayed within the measured value above 42.5 ℃ and three “Di”alarm sounds will be made after completing the test.
Check Object surface temperature
Toggle the left and right switching button and switch it to the right to set surface object temperature measurement mode, and point the probe at the object surface then press the measurement button to measure the object surface temperature. The measurement will be completed within 1 second and a “Di”sound will be made after the test.
Safety precautions
WARNING
It is very dangerous to judge and treat the measurement results by
yourself.Please follow the doctor’s instructions. Self judgment may lead to
deterioration of the condition.|
---|---
High or chronic fever requires medical attention, especially for young
children. Please consult a doctor. Otherwise, the disease may worsen
Please keep the battery out of the reach of children.
Otherwise, children may swallow it. If you swallow the battery accidentally,
please contact your doctor immediately.
Please remove the battery when it is not used for a long time damaging the
body. Otherwise, the battery may leak liquid, heat, rupture, etc, (more than 3
months).
Please keep the body out of the reach of children. At the same time, please
avoid letting children use the body alone. Otherwise, children may be injured|
After use, please handle the battery according to the requirements of the
residence. If it is disposed of as combustible, it may cause fire due to
battery explosion, resulting in burns and injuries.
Do not use this product to measure any object whose temperature exceeds 80.0
℃. Otherwise, it can not be measured correctly and there is a risk of injury
ATTENTIONS
Do not disassemble, repair or modify the body. It may cause errors in the
measurement results or machine failure|
---|---
The body is not waterproof. Use with care to prevent liquids (alcohol, water
or hot water) from entering the body. When the body is wet due to contact with
steam, please wait until it dries or wipe it gently with a soft dry cloth. It
may cause errors in the measurement results or machine failure.|
If there is a temperature difference between the body storage place and the
place where you want to measure, please put the body Stay in the room where
you want to measure for more than 30 minutes so that it reaches room
temperature first,Then measure. Otherwise, the measurement result may be low.
If the forehead is cold, wait until the forehead is warm before taking a
temperature measurement. If you use ice bags or ice packs, or when you enter
the room from outside in winter, do not use them immediately. Otherwise, the
measurement result may be low.
When the detection lens becomes dirty, please use a soft dry cloth or cotton
swab to gently wipe it. Do not wipe the probe lens with a paper towel or
towel. May cause machine failure.
Do not collide, fall, trample or vibrate the body strongly. Damage to the body
may result in injury.|
Do not use the mobile phone near the body. There is a risk of deviation of the
body
Please do not use the body where there is strong static electricity or
electromagnetic wave. It may cause errors in the measurement results or
machine failure.
Do not touch the camera or exhale. It may lead to inaccurate measurement
results.
Do not attempt to measure when the body is wet. It may lead to inaccurate
measurement results.
Specifications
- Sensor: thermopile type
- Minimum division value: 0.1℃
- Accuracy: 35.0℃~42.0℃ within limits ±0.2℃, outside the scope±0.3℃
- Measurement range: 32℃~42.5℃
- Power supply: DC 3V Two AAAbatteries
- Normal working conditions: 16-35 ℃, humidity ≤ 85% RH
- Storage temperature and humidity: -20~55 ℃, humidity ≤ 85% RH (no corrosive gas and well ventilated room)
- Boundary dimension: 145x83x43mm
- Body weight: 116.5g (excluding battery)