FORA D40g Blood Pressure and Glucose Monitoring System User Guide
- June 6, 2024
- FORA
Table of Contents
Blood Pressure and Blood Glucose Monitoring System
Quick Start Guide
Product Overview
Start with the meter off (no test strip inserted). Hold S until the meter turns on.
Setting the date and the time
- With the year flashing, press M until the correct year appears. Press S.
- Repeat with the month/day/hour/minute. Press M until the correct value appears. Press S.
Volume:
- Press M for desired volume (0 mute – 7 highest). Press S.
Language:
- Press M to select L1 (English) or L2 (Spanish). Press S.
AS (Auto Send):
- Press M to set auto-send ON or OFF. Press S.
Delete Memory:
- Option to delete memory. Press S to skip this step.
D40g Meter Information:
- Intended for single patient use only.
- Meter will switch off automatically if left idle for 3 minutes.
- The meter should transmit data automatically. For more information on manual data transmission or signal quality check, please refer to the user manual.
Blood Glucose Strips:
- Strips have an expiration date. Please check the strip container for the expiration date before using it.
- Strips expire 90 days after opening. Please mark the date of opening on the strip container to calculate the expiration date.
- Expired strips should not be used because they could provide inaccurate results.
- Strips can be contaminated if not stored in the original container.
- Storage conditions: 39.2ºF – 104ºF (4ºC – 40ºC).
Performing a Test
Blood Glucose:
- Wash your hands.
- Insert lancet into the FORA lancing device and close.
- Insert test strip into the meter.
- Press the lancing device against the fingertip and click the release button.
- Apply the blood sample to the absorbent hole of the test strip. Normal 118-160 Normal 118-160
- Wait 5 seconds for results.
- Eject the test strip from the meter to ensure the results are automatically uploaded to the 24/7 HealthView Telehealth system using the cellular signal.
Blood Pressure:
- Stretch your arm in front of you with your palm facing up.
- Slide and place the cuff onto your arm with the air tube and artery mark region (in red) toward the lower arm. Make sure the cuff is about the same height as the location of your heart. Wrap and tighten the cuff above your elbow.
- Leave a little free space between the arm and the cuff, you should be able to fit 2 fingers between them.
- Sit down for at least 10 minutes before measuring.
- Place your elbow on a flat surface. Relax your hand with the palm facing up.
- Press the power button. All the LCD symbols will appear. Then the cuff will begin to inflate automatically.
- The heart symbol will flash when a pulse is detected during the inflation.
- After the measurement, the monitor displays the systolic pressure, diastolic pressure, and pulse rate.
FAQ
How does the D40g work?
The D40g measures the systolic and diastolic blood pressure and pulse rate by
using a non-invasive technique in which an inflatable cuff is wrapped on the
upper arm. The device also measures blood glucose from fresh capillary whole
blood samples. It automatically uploads data to the 24/7 HealthView Telehealth
System using 4G cellular technology.
What’s the proper way to take a measurement? To test your blood pressure, make
sure you’ve been sitting for at least 10 minutes, your elbow is on a flat
surface with your palm
facing up, and the cuff is about the same level as your heart. Do not talk or
move during the measurement. To test your blood glucose levels, wash and dry
your hands before starting, insert the test strip into the device, rub the
puncture site for about 20 seconds, puncture your finger, wipe away the first
drop of blood, squeeze the finger to produce a larger sample size, and
carefully touch the finger to the tip of the test strip allowing the absorbent
hole to sip in the blood.
How often do I need to charge the battery?
Please charge battery for 5 hours before first use. The lifespan of your
battery will vary considerably with how it is used, how it is maintained and
charged, temperature, and other factors such as frequency of testing. Use the
A/C adaptor (input: 100-240V / output: 6V 1A) to recharge the 3.7V
rechargeable Li-ion battery. After about 5 hours, the battery will be fully
charged, as indicated when the green battery light disappears.
Can I use the meter without the battery?
Yes, you can use the device to measure your blood pressure when it is plugged
into the A/C adaptor without a battery. However, it will not upload any
readings until you insert the battery again. You will not lose any readings
while the battery is not inserted.
Where can I review my data?
Since the D40g is not Bluetooth-enabled, it will not connect to an app on a
smartphone. You can check the memory on the D40g for the latest 864 readings
by pressing the M button or log in to the 24/7 HealthView Telehealth patient
portal at telehealth. for care. com to review your latest readings and keep
track of your trends. The product user manual can be downloaded from the
website product page.
What is a control solution and how do I use it?
Control solution is used to check if the meter and test strips are properly
working together as a system. You only need a control solution if you are
using the meter to measure your blood glucose levels, and only when you get a
new set of test strips or think your results are not accurate. To use the
control solution, insert the test strip into the meter, as usual, apply the
second drop of control solution to the test strip (do not apply control
solution directly onto the test strip), and compare the results with the range
printed
on the control solution vial. Please note the expiration date, and discard any
control solution that has expired or been open for longer than 3 months.
What are the cleaning and disinfecting procedures for the D40g?
Clean the meter when you see any dirt on it. Disinfect the meter at least once
a week to prevent infection. To clean, use one disinfecting wipe on exposed
surfaces of the meter to remove visible dirt, blood, or other fluids. Do not
use organic solvents to clean the meter. To disinfect, clean the meter first.
Then grab one disinfecting wipe and squeeze out any excess liquid to prevent
damage. Wipe all meter’s exterior surface displays and buttons, but be careful
not to allow excess liquid to get inside the test slot. Keep the meter wet
with disinfecting solution for a minimum of two minutes. Remove the wipe and
allow the surface to dry completely. Discard the wipe. Wash your hands
thoroughly after handling the meter, lancing device, and test strips to avoid
contamination. This device has been validated to withstand up to 6,000
cleaning and disinfecting cycles using the recommended disinfecting wipes. See
the user manual for more information.
For additional information on the D40g, please refer to the user manual.
Troubleshooting
Error Code| What It Means|
Solution
---|---|---
Err 1
Err 2| Inflation or pressure error.| Refit cuff tightly and correctly.
Relax and repeat the measurement. If the error still remains, please contact
customer service for help.
Err 3| Cuff pressure is too high.
Err 4
Err 5| No pulse rate detected or the pulse rate is too low.
| Appears when the batteries cannot provide enough power for a test.| Replace
or recharge the batteries immediately.
PCL Err 30| Unable to connect to the service.| Turn the device off and
on again to re-establish an in. For a better signal, move the device into a
more open area or closer to a window. If the problem still persists, please
contact the customer
PCL Err 40| No response from the server.
PCL Err 41| Service error.
PCL Err 42| Failure connecting to the service.
PCL Err 43| Connection overtime.
PCL Err 44| Command failure.
PCL Err 45| service for assistance. Data upload error.
PCL Err 48
PCL Err 49| Problem connecting to the service.
For questions on how to use the FORA medical devices, please contact the
FORA Customer Service Line at
1-888-307-8188
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>