Air Guard AG-800X Portable Fog Sanitization Machine User Manual
- June 6, 2024
- Air Guard
Table of Contents
AG-800X
Antibacterial Vaporizer
USER MANUAL
Safety Information
****Thank you for choosing Air Guard. Please read the following safety information carefully before operating the machine. This information includes important safeguards about installation, usage, and maintenance. Pay attention to all warning labels and instructions in this manual and print on the machine.
- Keep this device dry.
- Always connect to a grounded circuit to avoid risk of electrocution.
- Before connecting the machine to power, always check the voltage indicated on the machine matches to your local AC voltage. Do not use the machine if AC power voltage does not match.
- Disconnect the machine from AC power before servicing and when not in use.
- If the supply cord is damaged, contact your local dealer for replacement.
- This product is for indoor use only! Do not expose to rain or moisture. If fluid is spilled, disconnect AC power and clean with a damp cloth. If the fluid is spilled onto electronic parts, immediately unplug the machine and contact your local dealer for advice.
- No user-serviceable and modifiable parts inside. Never try to repair this product, an unauthorized technician may lead the machine to damage or malfunction.
- For adult use only. Children are being supervised not to play with the machine. Never leave the machine running unattended.
- The machine is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
- Installed in a well-ventilated area. Provide at least 50 cm of space around the machine.
- Never add flammable liquid of any kind to the machine.
- Make sure there are no flammable materials close to the machine while operating.
- Only use Air Guard Antibacterial Solution. Other solutions may lead to heater clog and malfunction.
- If the machine fails to work, unplug the machine and stop operation immediately. Contact your local dealer for advice.
- Before transporting the machine, make sure the fluid tank is completely drained.
- Air Guard Antibacterial Solution may present health risks if swallowed. Do not drink the smoke solution. Store it securely. In case of eye contact or if the solution is swallowed immediately look for medical advice.
Unpacking and Inspection
Immediately upon receiving the antibacterial vaporizer, carefully unpack the carton, check the content to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retain the packing material for inspection.
What is included:
1 x AG-800X Antibacterial Vaporizer
1 x 2m Power Cord
1 x Wireless remote control
1 x User Manual
Product Dimensions
Product Overview
Setting Up
Step 1: Place the vaporizer on a flat surface and in a suitably large area
with at least 50 cm of open space around the machine.
Step 2: Fill the fluid tank with Air Guard Antibacterial Solution.
Step 3: Connect the machine to a suitably rated power supply. To determine the
power requirement for the machine refer to the label on the back of the
machine.
**** Always connect the machine to a protected circuit and ensure it is
properly grounded to avoid the risk of electrocution.
Step 4: Turn on the machine and allow it to heat up, while the machine is
heating up the LED status light on push button will flash. Heat up takes
approximately 2 minutes. Once the machine reaches operating temperature, the
LED status light will turn solid.
Step 5: To start making fog , press the push button located on the handle.
Press the push button again to stop
Step 6: To tu rn off the mac hine, put the power switch to OFF position.
Operation
Manual Operation
AG-800X is preprogrammed to emit fog for 30sec. The press push button located
on the handle to activate, the machine will automatically stop after 30sec.
Press the push-button any time to stop.
Wireless Operation
Wireless remote control system W-1 consists of a transmitter equipped with two
buttons to activate, deactivate and an onboard receiver attached to the rear
panel of AG-800X.
Press [A] button to emit fog and press [A] button again to stop.
In an unobstructed open space, the effective distance is 50 meters, usage
depending on obstacle level the effective distance is 10-25 meters.
Transmitter setting
By default [A] button is set to activate and deactivate. To change the
activation button, simply press the desired button within 15 seconds after
power is turned on.
Registering a transmitter
Transmitters can be paired or deleted from the receiver. Each receiver can
pair up to 5 transmitters.
Follow the steps below to pair or delete a transmitter from the receiver.
Step 1: Turn on the machine
Step 2: Press [A] or [B] button within 15 seconds to register
To register multiple transmitters follow step above and press [A] or [B]
button on all registering transmitters within 15 seconds after power is turn
on. When the new transmitter is registered the previous transmitter will be
automatically deleted.
Transmitter battery replacement
If the effective distance seems to decrease, it is possible the battery level
is low and requires replacement. In order to replace the battery, undo the
three screws on the back of the transmitter to release the cover. Replace with
the same type and specification of battery which is 27A 12V
Fluid
Use Air Guard Antibacterial Solution for AG-800X. The machine is tested and
calibrated with these authorized fluids to achieve
the best performance. Warranty will be void if any other type of liquid is
used. Improper use of liquid may lead to machine failure and danger.
Fuse Replacement
**** Disconnect AC power before resetting the breaker. Only replace the
fuse with the same type and rating.
Step 1: Disconnect AC power.
Step 2: Use a flat-head screwdriver to release the fuse holder.
Step 3: Replace fuse with exact same type and rating as indicated below.
Step 4: Reinsert fuse holder
Fuse
100-120V = 7A 250V
220-240V = 4A 250V
Technical Specifications
Input voltage| US model : AC 100-120V, 50 / 60Hz 6.7AEU model : AC 220-240V,
50 / 60Hz 6.67A
---|---
Rated power| 800 W
Warm-up time| 2 minutes (approx)
Fluid consumption| 10 ml / min (100% output)
Fluid tank capacity| 0.8 Liters
Compatible fluid| Air Guard Antibacterial Solution
Ambient temp/ range| 0℃ – 40℃ (32℉-104℉)
Control| Manual
Wireless
Dimension| L 315 W 128 H 165.5 mm
Weight| 3.8 kg (8.4 lbs)
M22 Moisture Co., Ltd.
Tel : +886 3 2227470 Fax : +886 3 2227469
www.airguard.com.tw e-mail :
sales@airguard.com.tw
C08AG8X01
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>