HomeSeer HS-LS100+ Z-Wave Leak Sensor Instruction Manual
- June 6, 2024
- HomeSeer
Table of Contents
HS-LS100+ Z-Wave Leak Sensor
OVERVIEW
HS-LS100+ is a compact, easy-to-install leak sensor. It is designed to control other Z-Wave devices directly or it may be used with a variety of Z-Wave certified home controllers to launch automation events or scenes.
Applications
- Use to activate Z-Wave devices such as sirens or water valve controllers when a leak is sensed.
- Use to trigger home automation events (aka “scenes”, “automation” or “robots”) when a leak is sensed.
Configuration
HS-LS100+ is battery-powered and includes a Z-Wave network button, LED indicator, and a magnetic wall mount/wired probe assembly. The unit may be deployed as a free-standing sensor (using built-in probes) or as a wired remote sensor (via the wall mount/wired probe assembly).
Z-Wave Network Installation
Remove the back cover by rotating counter-clockwise and install 1 ER14250
battery (included) inside HS-LS100+. Include the sensor into your Z-Wave
network using the instructions below. Then, replace the back cover.
Note: HS-LS100+ may be included in your Z-Wave network as a “secure”
device or as a “non-secure” device. Use the instructions below to include or
exclude HS-LS100+ to/from your Z-Wave network.
Secure Inclusion (recommended if your home controller supports “S0” or “S2”
Z-Wave encryption)
- Put your home controller into Z-Wave ‘inclusion’ mode.
- Press and hold the Z-Wave network button for 5 seconds, then release it. Wait for the inclusion process to finish.
Non-Secure Inclusion
- Put your home controller into Z-Wave ‘inclusion’ mode.
- Quickly press and release the Z-Wave network button once. Wait for the inclusion process to finish.
Exclusion
- Put your home automation controller into Z-Wave ‘exclusion’ mode.
- Quickly triple-press the Z-Wave network button. Wait for the exclusion process to finish.
Reset (Use this procedure to reset HS-LS100+ to factory settings when the Z-Wave controller is missing or inoperable).
- Press and hold the Z-Wave button for 20 seconds. Release the button once the LED stops blinking and glow solidly.
Physical Installation
Free-standing installation: Simply place the leak sensor on a flat horizontal
surface in the area where a leak might occur.
Remote installation: Install the included magnetic wall mount/wired probe
assembly in the location of your choice (using the supplied mounting hardware)
and attach the HS-LS100+ to it by aligning the 3 probes with the 3 holes in
the mounting bracket.
Position and install the wired probe in the area where a leak might occur or
where you wish to detect liquid.
Leak Sensor Operation
HS-LS100+ is designed to transmit a Z-Wave command when liquid is sensed. It will also transmit another command when the liquid is no longer sensed.
Shock Sensor Operation
The shock sensor is designed to transmit a Z-Wave command when HS-LS100+ has been physically moved. This sensor is especially helpful in determining whether the unit has been removed from its mount or tampered with.
Battery Sensor Operation
The battery sensor is designed to report battery level with a Z-Wave command every 43200 seconds (12 hours). If desired, HomeSeer users can adjust this interval (0-2678400 seconds) by accessing the settings on the Z-Wave tab of the root device.
Z-Wave Association Information
HS-LS100+ supports Group 1 association. Group 1 reports the sensor’s status and battery if running on batteries.
Notes
- If your home controller supports “S2” security encryption, the Leak Sensor may be added as a ‘secure’ device to your network. If not, it will add as a non-secure device. This will not affect the functionality of the unit.
- For more information, visit homeseer.com.
ADVANCED CONFIGURATION (accessible via the “Root device” in a HomeSeer System. Before adjusting these settings, tap the network button 4 times to wake the unit.)
Parameter | Settings | Parameter | Settings |
---|---|---|---|
14 | Enable / Disable Basic Set Command Available: 0=disable, 1=enable | ||
Default: 0 | Size: 1 byte | 20 | Set High Temperature Trigger Value |
Available: -670 to 2570 (-67 to 257 °F)
Default: 1040 (104 °F) | Size: 2 bytes
15| Set Value for Basic Set Command
Available: 0=Sends 255 value when leak sensed
Available: 1=Sends 0 value when leak sensed
Default: 0 | Size: 1 byte| 22| Set Low Temperature Trigger Value
Available: -670 to 2570 (-67 to 257 °F)
Default: 320 (32 °F) | Size: 2 bytes
17| Leak Report Interval
Available: 0=disable, 1 to 255 (minutes)Default: 5 | Size: 1 byte| 24|
Enable Blinking LED When Alarm Triggers
Available: 0=disable, 1=enable
Default: 1 | Size: 1 byte
18| Enable Shock Sensor
Available: 0=disable, 1=enable
Default: 1 | Size: 1 byte| 32| Set Value for Low Battery
Available: 10-50 (%)
Default: 20 (%) | Size: 1 byte
19| Temperature Report Interval
Available: 3 to 240 (multiply by 10 for minutes: 3 = 30 min)
Default: 144 | Size: 1 byte| Note: Parameter 18 (“Enable Shock Sensor”)
and parameter 19 (“Temperature Report Interval”) are disabled by default, to
conserve battery life.
SPECIFICATIONS
Operating Temp Range | 0ºC to 40ºC | Power | Requires (1) ER14250 Battery |
---|---|---|---|
Z-Wave Frequency | Range Z-Wave Certification | 908 MHz (US) | Up To 300 Ft |
lines of sight Z-Wave Plus | Dimensions | Sensor (main unit): 2.75 x 2.75 x .75 |
(inches)
LIMITED WARRANTY
HomeSeer Technologies, LLC will repair or replace, at its option, any part of the device, which proves to be defective in workmanship or material under normal use, in the USA except in the states of Alaska or Hawaii, for a period of one year from the date the device is purchased. During the warranty period, HomeSeer Technologies, LLC will repair and provide all parts necessary to correct such defects, free of charge, provided the device has been operated in accordance with the manufacturer’s guidelines. The Customer will return the device to HomeSeer Technologies, LLC for testing and repair or replacement. Should you need service, during the warranty period or beyond, contact HomeSeer to obtain return authorization before shipping your device to HomeSeer Technologies, LLC.
This product employs or practices certain features and/or methods of the
following U.S. Patents: U.S. Patent Nos.6,891,838, 6,914,893 and 7,103,511.
HomeSeer | 10 Commerce Park North, Unit 10 | Bedford, NH 03110 |
HomeSeer.com | Doc: HS-LS100-en-v2
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>