DUKART ROOMMAP500 My Air Protector User Manual

June 6, 2024
DUKART

DUKART logo Ref. No.:
D570-0003-DAD01

DUKART ROOMMAP500 My Air Protector - logo

Index: 01
Detailed analysis document

Product Designation:

MY AIR PROTECTOR ROOMMAP 500
Article Code: P0102-01-000001
Designation:
Examination of the ROOMMAP500 for emission of ozone

Summary:

The ROOMMAP500 was tested with an ozone measuring instrument for the emission of ozone. No emission of ozone was found.

DUKART ROOMMAP500 My Air Protector

| Name| Date| Signature
---|---|---|---
repaired:| M. Boesner| 2020-07-02|
Checked:| D. Dauer| 2020-07-06|

introduction

UV radiation with a wavelength smaller than 240nm generates ozone from atmospheric oxygen. This is dangerous for humans and animals in high concentrations. In the  ROOMMAP500, UV-C radiation with a wavelength of 254nm is used, a wavelength which, according to the literature, does not generate ozone. This must be confirmed by testing.

content and purpose

The purpose of this examination is to test whether the ROOMMAP500 produces and emits ozone.

measuring conditions

  • humidity 41,3%
  • ambient temperature 22,3°C
  • closed room, no additional air circulation by air conditioners or ventilation. – G2 filter attached
  • G4 filter removed
  • Ozone measurement instrument: Trotec OZ-ONE
    serial number 1712213

DUKART ROOMMAP500 My Air Protector - measuring
conditions

Figure 1: Ozone measuring instrument used

description of the measurement

The ozone measuring instrument was switched on, the warm-up period of 3 minutes was observed. The instrument was now ready to use. At this time the ROOMMAP500 had been activated for 24 hours in a closed room at low fan speed. The ozone measuring instrument was now placed for 5 minutes in less than 5cm distance near the air exhaust of the ROOMMAP500, see figure 2. The display shows the value of the measured ozone below “ppm”, meaning “parts per million”. For the complete duration, the display showed “0.00ppm”.

DUKART ROOMMAP500 My Air Protector - measurement

Figure 3: actual measurement

result

During the operation of the ROOMMAP500, no amount of ozone emits the device that may be measured with the Trotec OZ-ONE. Since all measured values do not exceed 0.00ppm, a statistical evaluation is not required.

Appendixes

Reference Name of Document
1 Trotek_Kalibrierzeugnis.pdf

Amendment Record

Issue Date Changes
01 2020-07-02 Initial Issue

DUKART logo

Template:
D000-0001-DAD01
The reproduction, distribution, and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders
will be held liable for the payment of damages. All rights reserved in the event of the grant of a  patent, utility model, or design.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DUKART User Manuals

Related Manuals