MSXIM 88935MW 52 Ceiling Fan Installation Guide

June 27, 2024
MSXIM

MSXIM 88935MW 52 Inch Ceiling Fan Installation Guide

Before Getting Started

Read the instructions carefully prior to assembling the product.
When you open the package with a sharp tool like box knife, be careful not to damage the components inside.
Carefully remove all packaging materials and retain for future use.
Keep all hardware parts and packaging out of reach or small children.
Choosea dean, level, spaciousassemblyarea. Avoid hard surfaces thatmay damage the product.
Ensure that you have all required contents for complete assembly.
Take care when lfting. Assemble the product in close proximity to where you intend to install it.
Donot over tighten the screws and bolts as this may damage the threads.
Do not let children play with this product.
Risk of suffocation!
Keep packaging materials away from children.

Lamp Care Instructions

Carefully read through the instruction sheet before assembly and using the product.

Caution Theresia risk of shock!

Disconnect from power source before assembling orcleaning.
Switch off, unplug andallow bulb to cool before replacing bulb o cleaning.
Only use the recommended bulb type and do not exceed the maximum wattage as it could cause fire.
Check the product cord to be sure s free torn or frayed.

**Cleaning & Maintenance

**

On polished finishes, often using talc powder can reduce the appearance of fingerprints and other smudges.
For respective shade surfaces, use the appropriate deansers, .. glass cleaner, stone polish, & wood polish.
Clean with soft cloth and a mild detergent. Do not use abrasive or harsh deaners.
Periodically (every 90-180 days) make sure that the screws are fully tightened.
Prolonged exposuretoheat sourcesmay cause glazing, meltingandscorching, oreven cause color o fade.

Safety Information

  1. To reduce the risk of electric shock, ensure the electrioty has been turned off at the circuit breaker or fuse box before you begin.
  2. All wiring must be in accordance with the National Electrical Code ANSUNFPA 70-1999 and local electrical codes. Electrical installation shoule be performed by a qualified licensed electrician.
  3. The outlet box and support structure must be securely mounted and capable of reliably supporting 35 lbs (15 9kg) se only Ul I isind outlet boxes marked “Acceptable for Fan Support of 35 lbs (15.9kg) or less
  4. The fan must be mounted with a minimum of 7 ft. (2m) clearance from the trailing edge of the blades to the floor
  5. Do not operate the reversing switch while the fan blades are in motion. You must turn the tan off and slop the biades before you reverst the blade direction.
  6. Do not place objects in the path of the blades
  7. Electrical diagrams are for reference only Lighe kits that are not packed with the fan must be UL-listed and marked suitable for use with the model fan you are installing. Switches must be UL General Use Switches Refer to the instructions packaged with the light kits and switches for proper assembly
  8. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment grounding conductor on ine side of the outlet box
  9. All setscrews must be checked and retightened where necessary before installation

NOTE: These are approximate measures. They do not include the Amps and Wsttage used by the light kit.

WARNING. To reduce the risk of personal injury, do not bend the blade brackets (slso referred to as flanges) during assembly or after installation. Do not insert objects in the path of the blades
WARNING: Remove the rubber motur stops on the bottom of the las before installing the blades or testing the molor
WARNING: To reduce the nsk of firm or slectric shock, do not use this fan with any solid-state speed control device
WARNING To avoid posable noctrical shock, tum the electraty off at the main fuse box before wiring. If you fool you do not have enough slectrical wiring knowledge or experience, contact & lcensed electrican
WARNING Elecincal diagrams are for reference only Optional use of any light kit shall be UL listed and markod suitable for use with this bun
WARNING : To reduce the risk of fire, electric shock, or personal injury, mount to cutiet boor marked “Acceptabio for fan Support of 35 lbs (159kg) or less and use the soews provided with the outlet bea
CALITION To reduce the ask of personal injury, use only the screws provided with the quiet box
CAUTION : To avoid personal injury or damage to the fan and other items, use caution when working around of cleaning the tan

TOOLS REQUIRED

  • Phillips screwdriver

  • Flat blade screwdriver

  • Adjustable wrench

  • Electrical tape

  • Wire cutter

  • Step Ladder

HARDWARE INCLUDED

NOTE: Hardware not shown to actual size.

  • **AA

**

  • BB

  • CC

  • DD

  • EE

  • FF

Part Description Quantity
AA Blade attachment screws 16
BB Wire connecting nut 3
CC Extra blade bracket screw 1
DD Wood screw 2
EE Mounting screws 2
FF Pull chain 1

PACKAGE CONTENTS

  • **A

**

  • **B

**

  • **C

**

  • **D

**

  • **E

**

  • **F

**

  • **G

**

P art Description Quantity
A Slide-on mounting bracket (inside canopy) 1
B Ball/downrod assembly 1
C Canopy 1
D Fan-motor assembly 1
E Decorative motor collar cover 1
F Blade 5
G Blade bracket 5

Installation

MOUNTING OPTIONS

WARNING :To reduce the risk of fire, electric shock, or personai injury, mount to outiet box marked “Acceptable for fan Support of 35 Ibs.(15.9kg) or less,” and use the screws provided with the outlet box. An outlet box A commonly used for the support of lighting fixtures may not be acceptable for fan support and may need to be replaced. If in doubt, consult a qualified electrician.

If your ceiling fan does not have an existing UL-listed mounting box, then install one using the following instructions:

  • Disconnect the power by removing the fuses or turning off the circuit breakers.

  • Secure the outlet box directly to the building structure. Use the appropriate fasteners and materials. The outlet box and support structure must be securely mounted and capable of reliably supporting 35 Ibs. (15.9kg). Use only UL Listed outlet boxes marked “Acceptable for Fan Support of 35 Ibs. (15.9kg) or less.” . Do not use a plastic outlet box.

The illustrations below show three different ways to mount the outlet box.

NOTE : You may need a longer downrod to maintain proper blade clearance when installing on a steep, sloped ceiling. The maximum angle allowable is 30° away from horizontal.

If the canopy touches the downrod, then remove the decorative canopy bottom cover, and turn the canopy 180° before attaching the canopy to the mounting plate.
To hang your fan where there is an existing fixture but no ceiling joist, you may need an installation hanger bar as shown above.

Assembly – Standare Ceiling Mount

  1. Preparing for mounting
    • Remove the mounting bracket (A) from the canopy (C) by loosening the two canopy screws (JJ) located in the round holes.
    • Remove and save the two canopy screws (ll) in the “L” shaped slots. This will enable you to remove the mounting bracket **(A).

**

  1. Routing the wires
    • Route the wires exiting the top of the fan motor (D) into the decorative motor collar cover (E)
    • Make sure the slot openings are on top and route the wires through the canopy (C) and then through the ball/downrod assembly **(B).

**

  1. Assembling the fan
    WARNING: Failure to properly install the locking pin A could result in the fan becoming loose and possibly falling.

    • Loosen, but do not remove, the setscrew (PP) on the collar on top of the motor housing (D).
    • Aling the holes at the bottom of the downrod (B) with the holes in the collar on top of the motor housing (D).
    • Carefully insert the hanger pin (B1) through the holes in the collar and downrod (B) . Be careful not to jam the hanger pin (B1) against the wiring inside the downrod (B).
    • Insert the locking pin (B2) through the hole near the end of the hanger pin (B1) until it snaps into its locked position.
    • Re-tighten the setscrew (PP) on the collar on top of the motor housing **(D).

**

  1. Attaching the fan to the electrical box
    WARNING: To reduce the risk of fire, electric shock or personal injury, mount to outlet box marked “Acceptable for fan support of 35 Ibs. (15.9kg) or less”, and use screws provided with the outlet box.

    • Pass the 120-Volt supply wires through the center hole in the mounting bracket (A).
    • Install the ceiling mounting bracket on the outlet box by sliding the mounting bracket (A) over the two screws (UU) provided with the outlet box. If necessary, use leveling washers (not included) between the mounting bracket (A) and the outlet box. Note that the flat side of the mounting bracket (A) is toward the outlet box. When using close-to-ceiling mounting, it is important that the mounting bracket be level.
    • Securely tighten the two mounting screws (UU).
  2. Hanging the fan
    WARNING: The locking slots of ceiling canopy are provided only as an aid to mounting. Do not leave the fan assembly unattended until all four canopy screws are engaged and firmly tightened.

    • Carefully lift the fan-motor assembly (D) up to the slide-on mounting bracket (A).
    • Insert the ball portion of the ball/downrod assembly into the socket of the slide-on mounting bracket.
    • Turn the ball/downrod assembly clockwise until it is seated with the tab of the slide-on mounting bracket aligned with the slot in the ball.
  3. Making the electrical connections
    WARNING: Each wire nut supplith this fan is designed to accept up to one 12-gauge house wire and two wires from the fan. If you have larger than 12-gauge house wiring or more than one house wire to connect to the fan wiring consult an electrician for the proper size wire nuts to use.
    ‘WARNING : Remove the rubber motor stops on the bottom of the fan before installing the blades or testing the motor.
    IMPORTANT: Use the plastic wire connectors (BB) supplied with your fan. Secure the connectors with electrical tape and ensure there are no loose strands or connections. 

    • The fan comes Lead wires for use with an extended downrod assembly. If using the 6 in. Downrod assembly (B) provided, you can cut the lead wires to your desired length (no shorter than 18 in.) This will make extra room in the canopy (C) , if you do not wish to cut the wires, you will need to neatly wrap them.
    • Connect the fan motor green wires to the household green or bare wire using a wire connecting nut (BB).
    • Connect the fan motor white wire to the household white wire using a wire connecting nut (BB).
    • Connect the fan motor black and blue wires to the household black wire using a wire connecting nut (BB).
    • Secure each wire connecting nut using electrical tape.
    • Term the wire connecting nut (BB) upward and push The wiring into the Junction box.
  4. Mounting the fan-motor assembly
    WARNING :When using the standard ball/downrod mounting, the tab in the ring at the bottom of the mounting bracket must rest in the groove of the hanger ball. Failure to properly seat the tab in the groove could cause damage to the wiring. 

    • Align the locking slots of the ceiling canopy (C) with the two screws (Il) in the mounting bracket (A) . Push up to engage the slots and turn clockwise to lock in place.
    • Firmly tighten the two mounting screws.
    • Install the other two mounting screws (JJ) (saved from Assembly Step 1 “Prepairing for mounting”) into the holes in the canopy (C) and tighten firmly.

WARNING: The locking slots of ceiling canopy are A provided only as an aid to mounting. Do not leave the fan assembly unattended until all four canopy screws are engaged and firmly tightened.

  1. Attaching the fan blades
    NOTE
    : Your fan blades are reversible. Select the@ blade side finish which best accentuates your decor.

    • Attach a blade (F) to a blade bracket (G) using the screws (AA) provided. Insert a screw into the blade bracket (G). Repeat for the two remaining screws (AA).

    • Tighten each screw securely.

    • Repeat steps 1-2 for the remaining blades.

  2. Fastening the blade brackets to the motor
    WARNING: Remove the rubber motor stops on the A bottom of the fan before installing the blades or testing the motor.

    • Remove the blade bracket screws from the fan-motor assembly (D). fasten the blade bracket (G) to the fan-motor assembly (D) by the blade bracket screws

    • Repeat this step for the remaining blade bracket.

  3. Attaching the fan pull chain

  4. Attach the pull chain extensions (FF) to the fan pull chain.

Operation

OPERATING YOUR FAN

Turn on the power and check the operation of the fan. The fan pull chain controls the fan speed as follows:
1 pull -High, 2 pulls – Medium, 3 pulls -Low, and 4 pulls -Off

The appropriate speed settings for warm or cool weather depends on factors such as the room size, ceiling height, and number of fans.
The slide switch controls the direction of the blades: forward (switch down) or reverse (switch up).

NOTE: Wait for the fan to stop before reversing the direction of the blade rotation.

A. Warm weather – (Forward) A downward airflow creates a cooling effect. This allows you to set your air conditioner on a higher setting without affecting your comfort.
B. Cool weather – (Reverse) An upward airflow moves warm air off of the ceiling. This allows you to set your heating unit on a lower setting without affecting your comfort.

Care and Cleaning

WARNING : Make sure the power is off before cleaning your fan.

  • Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure. It is not necessary to remove the fan from the ceiling.
  • Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning, as this could damage the motor, or the wood , or possibly cause an electrical shock. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer to minimize discoloration or tarnishing.
  • You can apply a light coat of furniture polish to the wood for additional protection and enhanced beauty. Cover small scratches with a light application of shoe polish.
  • You do not need to oil your fan. The motor has permanently-lubricated sealed ball bearings.

Troubleshooting

Problem Solution
The fan will not start.
  • Check the main and branch circuit fuses or breakers.
  • Cheech the line wire connections to the fan and switch wire connections in teh switch housing.

The fan is noisy.|

  • Ensure all motor housing screws are snug.
  • Ensure the screws that attach the blade bracket to the motor hub are tight.¨
  • Ensure the wire nut connections are not rattling against each other or the interior wall of the switch housing.¨
  •  Allow a 24-hour “breaking in” period. Most noises associated withe a new fan disappear during this time.
  • If you are using the Ceiling Fan light kit, ensure the screws securing the glassware are tight. Check that the light bulbs are also secure.
  • Ensure the canopy is a short distance from the ceiling.It shoulb not touch the ceiling.
  • Ensure your outlet box is secure and rubber isolator pads were used between the mounting plate and outlet box.

The fan wobbles.|

  • Check that all blade and blade arm screws are secure.
  • Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure from a point on the center of the blade to the point on the ceiling. Rotate the fan until the next blade is positioned for measurement, and measure from the same point on each blade to the ceiling. Repeat for each blade. Any measurement deviation should be within 1/8 in. Run the fan for ten minutes. If the minutes. If the fan continues to wobble please contact Customer Service and a balancing kit will be sent to you at no charge.


https://maximlighting.com/

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals