ALPS SKALLI1RM Asset Tracker Instruction Manual
- June 6, 2024
- ALPS
Table of Contents
ALPS
Skalli1RM Manual Instruction
Before use, please read this manual carefully and keep it for any later use.
- Not disassemble the product and do not try to carry out repairs by yourself
- Do not attempt to replace the batterie and do not dispose of the device and batteries in the Fire or in a hot oven.
- Do not crush or crumple the device
- Any use that does not conform to this manual will void the warranty and manufacturer’s liability
- Use only parts and components coming from ALPS Electric Europe GmbH.
- Do not leave any electronic equipment on the top of the Skalli1RMTracker
- Do not submerge the product in liquids
Product Details:
Skalli1RM is a networked device whose goal is to demonstrate the capabilities of the Sigfox network. It contains several sensors that evaluate data and send it to the Sigfox backend.
Initial Operation
Skalli1RM is already ready for operation upon delivery and after initializing
from the Sigfox ID number, the desired data will be transmitted automatically.
This means if no relocation within 24 hours, the WiFi data of the environment
will be read out and sent as a data packet to the Sigfox Backend. Based on a
sophisticated motion algorithm, Skalli1RM is capable to send the relevant GPS
location of the asset locations or as a fallback Wifi BSSIDs address. The GPS
/ WiFI location message will be transmitted via Sigfox network.
Alarm Button
- Activation (detector switch will be closed): 3-byte frame message “Tracker activation” will be sent to the Sigfox Backend
- Deactivation (detector switch is open): 2-byte frame message “Tracker is disassembled” will be send to Sigfox backend, if the detector switch will not be closed within the next 1 minute.
Technical characteristics
- Dimension [mm] (L x W x H): 175 x 61 x 21,5 mm
- Weight: 135 g
- Housing Material: PBTGF30
- Operating Temperature [°C]: -20 till +60
- Connectivity Sigfox, RC2: Class 0
- Localization technology (accuracy): GPS 5-10m
- Wifi Receive: 25-100 m
- Sigfox network-triangulation: up to 5 km Up to 8 years (at 2 messages per day)
- Battery Lifetime: Sigfox Ready, CE, FCC, Giteki
- Certification: IP67
- Protection Class: 90 %
- Maximum relative humidity: Not replaceable 5400 mAh 3.6V (Li-SoCl2)
- Battery: up to 2000 meters above sea level
- Operation:
- Mounting Method: Rivets, Screws, Zip-ties, Double side adhesive
Content of the Pack
1 x Skalli1RM Tracker
1 x Manual Instruction
Warning
- Any use of the Skalli1RM contrary to this manual may affect the function or permanently damage the module and result in the loss of any warranty claims.
- Do not dispose of the Skalli1RM in the normal household waste.
- Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. Alps Alpine Ltd will include the contents of this document in the end user’s manual for the commercial product.
FCCID: 2AT4VSKALLI1RM: IC: 26629-SKALLI1RM
This device complies with Part 15 of the FCC Rules and with Licence exempt RSS
standards of Industry Canada. Operation is subject to the following two
conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Exposure to radiofrequency energy.
The radiated output power of this device meets the limits of FCC/ISED Canada
radio frequency exposure limits. This device should be operated with a minimum
separation distance of 20 cm (8 inches) between the equipment and a person’s
body.
WARNING: Changes or modifications not expressively approved by the party
responsible for compliance could void the user’s authority to operate the
equipment. The term “IC:” before the radio certification number only signifies
that Industry Canada technical specifications were met.
Made in Ireland