FXLiminaire HP48 In-Grade Light Installation Guide

June 6, 2024
FXLiminaire

FX Luminaire logo

FXLiminaire HP48 In-Grade Light

FXLiminaire HP48 In-Grade Light

INSTALL

FXLiminaire HP48 In-Grade Light-1

  1. Install conduit, construction housing, and cover into the ground during construction. Run wiring into construction housing.
  2. Use a voltmeter to ensure 11 to 15 V at the fixture.
  3.  Connect wiring with a waterproof connector.
  4. Press fixture into housing.
  5. For servicing, use two flathead screwdrivers to remove fixtures from the housing.

CIRCUITING GUIDELINES

Guía para el cableado

FXLiminaire HP48 In-Grade Light-2

TRANSFORMERS

Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.

Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the fixtures as possible.

FXLiminaire HP48 In-Grade Light-3

DESIGNER | IN-GRADE LIGHT | HP48

Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.

WARNING – To reduce the risk of FIRE OR INJURY TO PERSON

  • Turn off/unplug and allow to cool before replacing the lamp.
  • The lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch the hot lens, guard, or enclosure.
  • Keep the lamp away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth. Oil from the skin may damage the lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock

  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
  • A luminaire shall not use tungsten-halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for the secondary cord that is suitable for wet locations.

LOW VOLTAGE CABLE SHALL

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum of 6″ (152 mm) in order to connect to the main low voltage cable.
  • Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a luminaire, or fitting.

These products contain a light source of energy efficiency class G.