EcoFlow DELTA Max User Manual
DISCLAIMER
Read all safety tips, warning messages, terms of use, and disclaimers carefully. Refer to the terms of use and disclaimer at https://ecoflow.com/pages/terms-of-use and stickers on the product before use. Users take full responsibility for all usage and operations. Familiarize yourself with the related regulations in your area. You are solely responsible for being aware of all relevant regulations and using EcoFlow products in a way that is compliant.
Specifications
General Info
Net Weight | Approximately 48lbs |
---|---|
Dimensions | 19.6×9.5x12in |
Capacity | 2016Wh 50.4V |
Certification | UL CE FCC RoHS Telec |
Wi-Fi | Supported |
Output Ports
AC (x6) | Pure Sine Wave, 2400W total (surge 5000W), 120V~ (50Hz/60Hz) |
---|---|
Max Device(s) Power Supported by X-Boost | 3400W |
USB-A (x2) | 5V 2.4A 12W max, per port |
USB-A Fast Charge (x2) | 5V 2.4A 9V 2A 12V 1.5A 18W Max, per port |
USB-C (x2) | 5/9/12/15/20V 5A 100W max, per port |
Car Charger | 12.6V 10A, 126W max |
DC5521 Output (x2) | 12.6V 3A, per port |
Input Ports
AC Charge | X-Stream Fast Charge 1800W max, 15A |
---|---|
AC Input Voltage | 100-120V~ 50Hz/60Hz, 15A |
Solar Charger | 11-100V 10A, 800W max |
Car Charger | Supports 12V/24V Battery, Default 8A |
Battery Info
Cell Chemistry | NCM |
---|---|
Shelf Life | 1 year (after a full charge) |
Cycle Life | 800 cycles to 80%+ capacity |
Protection | Over Voltage Protection, Overload Protection, Over Temperature |
Protection, Short Circuit Protection, Low-Temperature Protection, Low Voltage
Protection,
Overcurrent Protection
Environmental Operating Temperature
Optimal Operating Temperature | 68°F to 86°F |
---|---|
Discharge Temperature | -4°F to 113°F |
Charge Temperature | 32°F to 113°F |
Storage Temperature | -4°F to 113°F (optimal: 68°F to 86°F) |
Additional Connections
Smart Extra Battery| Supports up to 2 DELTA Max Smart Extra Batteries(sold
separately)
---|---
Smart Generator| Supported (sold separately)
Safety Instructions
2.1 Usage
- Do not use the product near a heat source, such as a fire source or a heating furnace.
- Avoid contact with any liquid. Do not immerse the product in water or get it wet. Do not use the product in rain or humid environments.
- Do not use the product in an environment with strong static electricity/magnetic fields.
- Do not disassemble the product in any way or pierce the product with sharp objects.
- Avoid using wires or other metal objects that may result in a short circuit.
- Do not use unofficial components or accessories. If you need to replace any components or accessories, please visit official EcoFlow channels to check relevant information.
- When using the product, please strictly follow the operating environment temperature specified in this user manual. If the temperature is too high, it may result in a fire or explosion; if the temperature is too low, the product performance may be severely reduced, or the product may cease to work.
- Do not stack any heavy objects on the product.
- Do not lock the fan forcibly during use or place the product in an unventilated or dusty area.
- Please avoid impact, falls, or severe vibrations when using the product. In case of a severe external impact, turn off the power supply immediately and stop using the product. Ensure the product is well fastened during transportation to avoid vibrations and impacts.
- If you accidentally drop the product into the water during use, please place it in a safe open area, and stay away from it until it is completely dry. The dried product should not be used again and should be properly disposed of according to Section 2.2 below. If the product catches fire, we recommend that you use the fire extinguishers in the following order: water or water mist, sand, fire blanket, dry powder, and finally a carbon dioxide fire extinguisher.
- Use a dry cloth to clean off dirt on the product ports.
- Rest the product on a flat surface to avoid damages caused by the product falling over. If the product is overturned and severely damaged, turn it off immediately, place the battery in an open area, keep it away from combustible matter and people and dispose of it in accordance with local laws and regulations.
- Ensure that the product is kept out of reach of children and pets.
2.2 Disposal Guide
- If conditions permit, make sure that the battery is fully discharged before disposing of it in a designated battery recycling bin. The product contains batteries with potentially dangerous chemicals, so it is strictly prohibited to dispose of it in ordinary trash cans. For more details, please follow the local laws and regulations on battery recycling and disposal.
- If the battery cannot be fully discharged due to a product failure, please do not dispose of the battery directly in the battery recycling box. In such a case, you should contact a professional battery recycling company for further processing.
- Please dispose of over-discharged batteries that cannot be recharged.
Getting Started
| |
---|---|---
3.2 LCD Screen
Battery Level Indicator: The indicator will repeatedly fill while
charging. If the product is at 0% charge, the indicator will flash to warn
you.
Wi-Fi Status: After pressing the IoT button for 3 seconds, the Wi-Fi
status will flash on the LCD screen which indicates that the product is ready
for pairing. There’re two ways to connect the product with the App, either
directly connecting to the product’s hotspot or using the Internet. If the App
is successfully connected to the product’s hotspot, the icon will keep
flashing; if it is successfully connected to the Internet, the icon will stay
on.
- See Section 5 for more troubleshooting steps.
3.3 General Product Usage
Product On, Product Off, LCD Screen On
Short press the Main Power Button to turn on the product; the LCD Screen will
light up and the battery level indicator icon will display.
The product enters sleep mode after 5 minutes of idle operation; the LCD
Screen will automatically turn off. When the product senses any load change or
operations, the LCD Screen will automatically light up. To turn the LCD
Screen on or off, please short press the Main Power Button.
To power off the product, press and hold the Main Power Button.
The default product standby time is 2 hours. With other Power, Buttons turned
off and no other load access for 2 hours, the product will automatically shut
down. The standby time can be set on the App.
USB Output Port
With the Main Power Button turned on, short press the USB Power Button to use
the USB Output Port. Short press the USB Power Button again to turn it off.
With the USB Power Button on, the product will not automatically shut down.
12V DC Output Port
With the Main Power Button turned on, short press the 12V DC Power Button
to use the 12V DC Output port. Short press the 12V DC Power Button again to
turn it off. With the 12V DC Power Button on, the product will not
automatically shut down.
AC Output Port
With the Main Power Button turned on, short press the AC Power Button to
use the AC Output ports. Short press the AC Power Button again to turn it
off.
The default standby time of the AC Output port is 12 hours.
Without any load access for 12 hours, the AC Power Button will automatically
turn off. Please turn off the AC power button when not in use to save power
consumption.
3.4 AC Charging
EcoFlow’s X-Stream fast charge technology is specifically for AC charging, offering 1800W of max input power. You can control the charging power through the AC Charge Speed Switch. When set to the top, you will have a charging speed of 1800W. When set to the bottom it’ll be at your custom speed, which is 400W by default, customizable in the EcoFlow app. In case of unusual situations where the AC input current remains higher than 20A, the X-Stream charging input port will initiate a self-protection function, and the Overload Protection Switch on the product will automatically pop up. After confirming that there is no product failure, you can press the Overload Protection Switch to resume charging.
The charging power can be adjusted through the AC Charge Speed Switch on the
back of the product. You can set the charging power range in the EcoFlow App.
Please use EcoFlow AC charging Cable for fast charging. AC Charging Cable
should directly plug into 15A(or above) wall outlet. EcoFlow takes no
responsibility for any consequences caused by failures to follow instructions,
including but not limited to charging with AC charging Cable.
3.5 Solar Charging
Users can connect solar panels in series as shown in the figure to recharge the product. The product supports 11-100V DC input, 10A max current, and 800W max charging power.
When using an EcoFlow solar panel to charge the product, please follow the
instructions that come with the solar panel.
Before connecting the solar panel, please ensure that the solar panel’s output
voltage is within 100V to avoid product damages.
3.6 Car Charging
Users can recharge the product through the Car Charging Input Port. It
supports 12V/24V car chargers and an 8A default charging current.
Please charge using the car charger after you’ve started the car to avoid
failure to start due to insufficient car battery. In addition, please make
sure that Car Charging Input Port and the Car Charging Cable are in good
condition. EcoFlow takes no responsibility for any losses or damages caused by
failures to follow instructions.
3.7 Using Smart Extra Battery
The product can be connected with up to two Smart Extra Batteries at the same time to meet higher capacity needs. Please refer to the user manuals of DELTA Max Smart Extra Battery and Smart Generator for detailed instructions.
Extra Battery, please follow the instructions below:
- Before connecting the product to a Smart Extra Battery, please make sure that both the product and the Smart Extra Battery are turned off.
- After connecting the product to a Smart Extra Battery, please make sure that both of their LCD screens display an extra battery icon before using it
- Do not directly connect or remove the Smart Extra Battery during charging and discharging processes. If you need to connect or remove it midway, please turn off the product first.
- Do not touch the metal terminals of the Smart Extra Battery connector with your hands or other objects. If foreign objects adhere to the metal terminals, please gently wipe them with a dry cloth.
3.8 APP
The EcoFlow App gives users the ability to control and monitor EcoFlow power
stations remotely.
Read the EcoFlow App user guide and access the download link here:
https://ecoflow.com/pages/ecoflow-app
Privacy Policy
By using EcoFlow Products, Applications, and Services, you consent to the
EcoFlow Term of Use and Privacy Policy, which you can access via the “About”
section of the “User” page on the EcoFlow App or on the official EcoFlow
website at https://ecoflow.com/pages/terms-of-use and
https://ecoflow.com/pages/privacy-policy
3.9 X-Boost
With EcoFlow X-Boost technology, the product can power a 3400W Max device
while the rated output power remains 2400W, avoiding operation failure due to
overload protection.
Under standard voltage conditions, the total maximum output of all AC output
ports is 2400W.
With the X-Boost enabled, all AC output ports can power devices that require
3400W Max in total while the rated output power remains 2400W. The X-Boost
will be automatically enabled when the total output of all output ports
exceeds 2400W.
supports 3400W max devices while the rated output power is still 2400W.
X-Boost Tips:
1. X-Boost is enabled by default; you can enable or disable it in the EcoFlow
App.
2. X-Boost is not available when the AC output is turned on in a recharging
state (in bypass mode) and when X-Boost is disabled.
3. X-Boost is not applicable for all electrical appliances; it’s incompatible
with appliances with strict voltage requirements. Appliances with voltage
protection (such as precise instruments) are not supported. X-Boost mode is
more suitable for heating devices. Please conduct your own tests with your
devices with X-Boost enabled.
3.10 Emergency Power Supply (EPS)
The product supports EPS. When you connect the grid power to the AC Input Port
of the product through an AC Charging cable, you can power electrical devices
through the AC Output Sockets (AC power will come from the grid and not the
power station in this situation). In case of a sudden blackout, the product
can automatically switch to the battery-powered supply mode within 30ms. As a
basic UPS function, this function does not support 0ms switching. Please do
not connect the product to any device that requires 0ms UPS, such as data
servers and workstations. Please test and confirm the compatibility before
using the product. We recommend that you only charge one device at a time and
avoid using multiple ones at the same time to avoid overload protection.
EcoFlow takes no responsibility for any device failures or data losses caused
by failures to follow instructions.
The EPS of the product only supports the following loads: below 1800W.
FAQS
-
What battery does the product use?
It uses a high-quality lithium-ion battery. -
What devices can the product’s AC output port power?
With 2400W rated power and 5000W peak power, the product’s AC output port can power most household appliances. Before you use it, we recommend that you confirm the power of the appliances first and ensure the power sum of all loaded appliances is lower than the rated power. -
How long can the product charge my devices?
The charging time is shown on the product’s LCD screen, which can be used to estimate the charging time of most appliances with stable power usage. -
How can I know if the product is charging?
When it’s charging, the remaining charging time will be shown on the LCD Screen. Meanwhile, the charging indicator icon begins to rotate with the remaining battery percentage, and the input of the power is shown on the right of the circle. -
How to clean the product?
Please gently wipe it with a dry, soft, clean cloth or paper towel. -
How to store the product?
Before storing, please turn off the product first, and then store it in a dry, ventilated place at room temperature. Do not place it near water sources. For long-term storage, please discharge the battery to 30% and recharge it to 60% every three months to extend its battery life. -
Can I bring the product on a plane?
No.
Troubleshooting
Indicator
| Problem|
Solution
---|---|---
|
OVERLOAD
|
Icons Flash
together
|
USB-A Overload
Protection
| Resume normal operation by
removing the electrical device
connected to the USB-A port.
|
OVERLOAD
|
Icons Flash
together
|
USB-C Overload
Protection
| Resume normal operation by
removing the electrical device
connected to the USB-C port.
| |
Icons Flash
together
|
USB-C High
Temperature Protection
| After the product cools down,
it will resume normal operation
automatically.
RECHARGING TIME
| |
Icons Flash
together
|
High Temperature
Charge Protection
| Charging can be resumed
automatically after the battery cools down.
| |
Icons Flash
together
|
High Temperature
Discharge Protection
| The power supply can be resumed
automatically after the battery cools down.
RECHARGING TIME
| |
Icons Flash
together
|
Low Temperature
Charge Protection
| Charging can be resumed
automatically after battery
the temperature rises above 41°F.
| |
Icons Flash
together
|
Low Temperature
Discharge Protection
| The power supply can be resumed
automatically after the battery
the temperature rises above 10°F.
|
OVERLOAD
|
Icons Flash
together
|
AC Output
Overload Protection
| Normal operation will be resumed
automatically after you remove the
overloaded device and restart the
product.
Electrical appliances should be used within rated power.
(Refer to X-Boost instructions to get more details about power limitations).
| |
Icons Flash
together
|
AC High
Temperature Protection
| Please confirm whether the fan inlet and outlet are blocked, if not, normal
operation will be resumed automatically after the product temperature drops.
| |
Icons Flash
together
|
AC Low
Temperature Protection
| Normal operation will be resumed
automatically after the product is
used at optimum environmental
temperatures.
| |
Icon Flashes
|
Fan Blockage
| Please check if the fan is blocked by foreign materials.
|
OVERLOAD
|
Icons Flash
together
|
Car Charger
Overload Protection
| The product will resume normal
operation automatically after you
remove the device connected to the car charger.
| |
Icons Flash
together
|
Car Charger High
Temperature Protection
| After the product cools down,
it will resume normal operation
automatically.
| |
Icon Stays On
|
Battery Failure
| Contact EcoFlow Customer Service
If the Alarm Prompt shows on the product LCD screen during use and does not
disappear after a restart, please stop using it immediately (do not try to
charge or discharge).
If you require any other assistance, please contact EcoFlow Customer Service.
What’s In the Box
Storage & Maintenance
- Please use or store the product in an environment temperature between 68°F to 86°F, away from water, heat, and other metal objects.
- For long-term storage, please discharge the battery to 30% and recharge it to 60% every three months.
- For safety, please do not store the product in an environment temperature higher than 113°F or lower than 14°F for a long time.
- If the remaining battery is less than 1% after you finish using the product, please recharge it to 60% before storing it. If the product is left idle for a long time with a severely low battery, irreversible damages may be caused to the battery cell and the product service life will be shortened.
- If the product has been idle for too long and the battery is severely low, it will enter a deep sleep protection mode. In such a case, please charge the product before using it again
References
- Terms of Use - EcoFlow
- EcoFlow
- Policy - EcoFlow
- EcoFlow Downloads | EcoFlow App, Manuals & More | EcoFlow US
- Privacy Policy - EcoFlow
- Terms of Use | EcoFlow
- EcoFlow | Portable Power, Solar & More – EcoFlow Europe
- Download Center – EcoFlow Europe