INSTRUMAX 3D GREEN Laser Level Instruction Manual
- October 27, 2023
- INSTRUMAX
Table of Contents
3D GREEN Laser Level
Instruction Manual
3D GREEN Laser Level
Congratulations on the purchase of laser level INSTRUMAX 3D GREEN!
Application
Cross Line Laser projects visible laser planes. It is used for determination
height, making horizontal and vertical planes.
Specifications
Laser | 1H 360° / 2V 360° |
---|---|
Light sources | 516 nm |
Laser safety class | Class 2, <1mW |
Accuracy | ±3 mm/10 m |
Self-leveling range | ±4° |
Operating range without/with receiver | 40/70 m |
Power source | 4xАА batteries/Charger |
Tripod thread | 5/8″ |
Operating temperature | -10°C +40°C |
Weight | 720 g |
Change of batteries
Open battery compartment. Insert batteries. Take care to correct polarity.
Close battery compartment.
ATTENTION: Take out batteries If you are not going to use the tool for a long
time.
Charger
It is possible to use charger to operate with the instrument.
Use charger for rechargeable batteries. Connect the charger to the hole that
is located on the housing of the instrument.
Then connect it to the main power. The instrument is in working condition and
rechargeable batteries are charging.
WARNING: Never use charger for ordinary batteries. Do not leave the
instrument unattended while using charger.
Parameters of the charger must correspond to the parameters of domestic
electricity. Output voltage must be no more than 5V.
Laser lines 1
Features 2
- Vertical laser window
- Horizontal laser window
- Keypad
- Compensator switch
- Battery compartment
- Tripod mount 1/4’’
- Hole for charger connection
- Rotating base (In leveling mode use the adjusting knob to rotate the instrument around the down dot by 180°)
Keypad 3
- Vertical line button
- Horizontal line button / Detector mode
- Laser lines LED / TILT LED
- Detector LED
Operation
INSTRUMAX 3D GREEN is a reliable and convenient instrument. It will be
irreplaceable instrument for many years.
Compensator switch (4) has 3 positions:
- Switch OFF (OFF). The instrument is switched off, pendulum is locked, keypad is inactive.
- Inclination position. The instrument is ON, pendulum is locked, keypad is active. It is possible to switch on (off) vertical or horizontal lines, detector mode with buttons (1) and (2). Laser lines are projected at any angle (lines are blinked 1 time each 5 sec.).
- ON position (ON). The instrument is switched on, pendulum is unlocked, it self-levels. It is possible to switch on (off) vertical or horizontal lines, detector mode with buttons (1) and (2). If the instrument is out of self-leveling range (±4º), all laser lines and indicator (3) starts blinking. Sound alarm.
Detector mode (not included). Use detector mode when operating in bright sunlight. Press button (2) to activate this mode. Indicator (4) lights up. Place the detector to the approximate location of the beam. Follow the instruction while searching laser beam.
Transportation
Move the switch (4) into position OFF. Place the instrument into the soft bag
or case. Do not drop the instrument during transportation.
To check the accuracy of line laser level 4
To check the accuracy of line laser level (slope of plane)
Place laser level on the tripod 5m away from the wall so the horizontal laser
line will be directed to the wall. Switch on the power. The instrument starts
to self-level. Mark point A on the wall to show the contact of laser beam with
the wall. Turn the instrument by 90° and mark points В, С, D on the wall.
Measure distance “h” between the highest and lowest points (these are A and D
points in the picture). If “h”is ≤ 6 mm, the measurement accuracy is good. If
“h” exceeds 6 mm, apply service center.
To check plumb
Choose a wall and set laser 5 m away from the wall. Hang a plumb with the
length 2.5 m on the wall. Turn on the laser and make the vertical laser line
meet the point of the plumb. The accuracy of the line is in the range if the
vertical line doesn’t exceed (up or down) the accuracy that is shown in the
specifications (±3 mm/10 m). If the accuracy isn’t corresponding with claimed
accuracy, contact the authorized service center.
Note: Because of construction of laser emitter laser beam may be
inhomogeneous and has different intensity of brightness along the perimeter in
different light conditions. Inhomogeneous of laser beam: laser patch of light
but the center of laser beam is identified. Different laser beam brightness:
difference of intensity is up to 50%. Care and cleaning Please handle
measuring instrument with care. Clean with soft cloth only after any use. If
necessary damp cloth with some water. If instrument is wet clean and dry it
carefully. Pack it up only if it is perfectly dry. Transport in original
container/case only.
Note: During transport On/Off compensator lock (3) must be set to
position “OFF”. Disregard may lead to damage of compensator.
Specific reasons for erroneous measuring results
- Measurements through glass or plastic windows;
- Dirty laser emitting window;
- After instrument has been dropped or hit. Please check the accuracy.
- Large fluctuation of temperature: if instrument will bemused in cold areas after it has been stored in warm areas (or the other way round) please wait some minutes before carrying out measurements.
Electromagnetic acceptability (EMC)
- It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigation systems);
- will be disturbed by other instruments (e.g. intensive electromagnetic radiation nearby industrial facilities or radio transmitters).
Laser class 2 warning label on the laser instrument 5
Laser classification
The instrument is a laser class 2 laser product according to DIN IEC
60825-1:2007 and Class II in accordance with CFR 21 § 1040 (FDA). This tool
may be used without need for further protective measures.
Safety instructions
Please follow up instructions given in operators’ manual. Do not stare into
beam. Laser beam can lead to eye injury (even from greater distances). Do not
aim laser beam at persons or animals.
The laser plane should be set up above eye level of persons. Use the
instrument for measuring jobs only. Do not open instrument housing. Repairs
should be carried out by authorized workshops only. Please contact your local
dealer. Do not remove warning labels or safety instructions. Keep instrument
away from children. Do not use instrument in explosive environment.
Warranty
This product is warranted by the manufacturer to the original purchaser to be
free from defects in material and workmanship under normal use for a period of
one (1) year from the date of purchase. During the warranty period, and upon
proof of purchase, the product will be repaired or replaced (with the same or
similar model at manufactures option), without charge for either parts of
labour.
In case of a defect please contact the dealer where you originally purchased
this product. The warranty will not apply to this product if it has been
misused, abused or altered. Without limiting the foregoing, leakage of the
battery, bending or dropping the unit are presumed to be defects resulting
from misuse or abuse.
Exceptions from responsibility
The user of this product is expected to follow the instructions given in
operators’ manual. Although all instruments left our warehouse in perfect
condition and adjustment the user is expected to carry out periodic checks of
the product’s accuracy and general performance. The manufacturer, or its
representatives, assumes no responsibility of results of a faulty or
intentional usage or misuse including any direct, indirect, consequential
damage, and loss of profits. The manufacturer, or its representatives, assumes
no responsibility for consequential damage, and loss of profits by any
disaster (earthquake, storm, flood …), fire, accident, or an act of a third
party and/or a usage in other than usual conditions.
The manufacturer, or its representatives, assumes no responsibility for any
damage, and loss of profits due to a change of data, loss of data and
interruption of business etc., caused by using the product or an unusable
product. The manufacturer, or its representatives, assumes no responsibility
for any damage, and loss of profits caused by usage other than explained in
the users’ manual.
The manufacturer, or its representatives, assumes no responsibility for damage
caused by wrong movement or action due to connecting with other products.
WARRANTY DOESN’T EXTEND TO FOLLOWING CASES:
- If the standard or serial product number will be changed, erased, removed or will be unreadable.
- Periodic maintenance, repair or changing parts as a result of their normal runout.
- All adaptations and modifications with the purpose of improvement and expansion of normal sphere of product application, mentioned in the service instruction, without tentative written agreement of the expert provider.
- Service by anyone other than an authorized service center.
- Damage to products or parts caused by misuse, including, without limitation, misapplication or negligence of the terms of service instruction.
- Power supply units, chargers, accessories, wearing parts.
- Products, damaged from mishandling, faulty adjustment, maintenance with low-quality and non-standard materials, presence of any liquids and foreign objects inside the product.
- Acts of God and/or actions of third persons.
- In case of unwarranted repair till the end of warranty period because of damages during the operation of the product, it’s transportation and storing, warranty doesn’t resume.
WARRANTY CARD
Name and model of the product ____
Serial number__
Date of sale____
Name of commercial organization
stamp of commercial organization
Warranty period for the instrument exploration is 12 months after the date of
original retail purchase.
During this warranty period the owner of the product has the right for free
repair of his instrument in case of manufacturing defects.
Warranty is valid only with original warranty card, fully and clear filled
(stamp or mark of the seller is obligatory).
Technical examination of instruments for fault identification which is under
the warranty, is made only in the authorized service center.
In no event shall manufacturer be liable before the client for direct or
consequential damages, loss of profit or any other damage which occur in the
result of the instrument outage.
The product is received in the state of operability, without any visible
damages, in full completeness. It is tested in my presence. I have no
complaints to the product quality. I am familiar with the conditions of
warranty service and i agree.
purchaser signature ____
Before operating you should read service instruction!
If you have any questions about the warranty service and technical support
contact seller of this product
For more information you can visit our website WWW.INSTRUMAXTOOLS.COM
INSTRUMAXTOOLS.COM
https://tm.by
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>