INTRODUCTION
Thank you for purchasing this CLARKE 400W Puddle pump with Auto Sensor.
This pump is designed for pumping clean water only. It is NOT designed for
pumping slurry, sludge, mud or heavily polluted water, or any water containing
chemicals or other acidic contaminants including saltwater.
These pumps are fitted with a thermal overload switch. If the pump overheats
for any reason, it will automatically switch the pump OFF. Once the pump has
cooled (at least 5-10 minutes), the pump will automatically restart.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt which will be
required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for the purpose for which it was
intended.
Faulty goods should be returned to their place of purchase, no product can be
returned to us without prior permission.
This guarantee does not affect your statutory rights.
ENVIRONMENTAL RECYCLING POLICY
Through the purchase of this product, the customer is taking on the obligation
to deal with the WEEE in accordance with the WEEE regulations in relation to
the treatment, recycling & recovery, and environmentally sound disposal of the
WEEE.
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing Waste
Electrical and Electronic Equipment (WEEE) at a recognized disposal facility.
SAFETY INSTRUCTIONS
GENERAL
- Read all instructions before use and save these instructions for future use.
- An approved residual current device (RCD) that has a tripping current of less than 30mA MUST be used for all operations.
- The electrical supply must be the same as that on the rating plate.
- ALWAYS make sure that your hands are dry when connecting or disconnecting from the mains supply.
- NEVER pull the mains lead to disconnect the pump from the mains socket.
- The main plug must be kept away from the water at all times.
- DO NOT allow children or unauthorized people to touch the pump, cables, or connections.
- Disconnect the pump from the main supply when not in use.
- If necessary have the pump repaired by a qualified person.
- Keep the mains lead away from heat, oil, and sharp edges.
- If you have to use an extension lead with this product, it must be designed for outdoor use and incorporate a cable suitable for use with Class I appliances.
- Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance.
PUMP SPECIFIC
- DO NOT pump explosive/flammable liquids or chemicals.
- NEVER allow the pump to run dry or operate out of the water (manual mode only).
- Submersible pumps should always be submerged and stored vertically.
- Disconnect the pump from the mains supply before placing it into or removing it from the water.
- ALWAYS check the plug and all cables for damage before use.
- DO NOT use the pump if damaged. Refer to qualified service personnel for repair.
- NEVER carry or lower the pump by the power cable or sensor cable always use the handle or a rope tied securely to the handle.
- NEVER insert your fingers into the pump whilst it is connected to the mains.
- NEVER use the submersible pump in a swimming pool when there are people or animals in the pool.
- Keep the pump clear of any sediment by standing it on a platform or brick or suspending it at a suitable depth.
- DO NOT use the pump if the water is liable to freeze, as this can cause damage to the pump.
Remove the pump from the water and store it in a frost-free location.
ELECTRICAL CONNECTIONS
WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAIN SUPPLY.
Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug or a suitably fused isolator switch. If the plug has to be changed because it is not suitable for your socket, or because of damage, it must be removed and a replacement fitted, following the wiring instructions are shown below. The old plug must be discarded safely, as insertion into a power socket could cause an electrical hazard.
WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: BLUE = NEUTRAL BROWN = LIVE YELLOW AND GREEN = EARTH
If the colors of the wires in the power cable do not agree with the markings on the plug.
- The BLUE wire must be connected to the terminal marked N or colored black.
- The BROWN wire must be connected to the terminal marked L or colored red.
- The YELLOW AND GREEN wire must be connected to the terminal marked E or colored green.
AN APPROVED RESIDUAL CURRENT DEVICE (RCD) WHICH HAS A TRIPPING CURRENT OF LESS
THAN 30 mA MUST BE USED.
If you are not sure, consult a qualified electrician. DO NOT try to do any
repairs.
ASSEMBLY
Remove all packaging and make sure that the unit has no visible damage.
Dispose of all packaging appropriately.
FITTING THE ELBOW
- Screw the elbow into the outlet port as shown.
- Connect a suitable hose (not supplied) to the pump outlet.
• Suitable hoses are available from your local Clarke dealer.
FITTING THE HOSE ADAPTER
The 3 step hose adaptor can be screwed onto the elbow if required.
- Fit the supplied nonreturn valve between the adaptor and the elbow.
- Trim the adaptor to the required size.
- Connect your hose (not supplied).
NOTE: Reducing the hose diameter will affect the maximum flow rate.
SETTING UP THE PUMP
AUTOMATIC OPERATION
This pump has an Automatic Sensor function. This activates the pump when the
water level sensor is immersed.
- The sensor can be ‘parked’ in one of three positions (High Medium, Low) on the pump as shown.
- The pump will run until the water level drops below the sensor.
• The pump continues to run for a further 3 minutes and then stops.
MANUAL OPERATION
The pump can also be switched on manually by inserting the sensor into the
socket on the side of the pump.
NOTE: If the sensor is inserted into the socket, the pump will run
continuously.
NOTE: Do not allow the pump to run dry.
POSITIONING THE PUMP
- Place the pump on a flat surface in the area that you want to drain.
• If there is sediment in the operating area, the pump should be placed vertically on house bricks, or similar.
• ALWAYS raise and lower the pump using a rope attached to the lifting handle.
• Take all necessary precautions as described on page 3.
USING THE PUMP
WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE PUMP IF IT
IS DAMAGED IN ANY WAY.
WARNING: THE WATER BEING PUMPED WILL BE POLLUTED IF THIS PUMP BECOMES
DAMAGED AND LUBRICANT WITHIN THE PUMP ESCAPES.
-
Connect the mains plug to the mains supply.
• Always use a high sensitivity residual current device (RCD) which has a tripping current of less than 30mA. -
Switch the mains power supply on.
• The pump will begin to drain water. -
When pumping is finished, disconnect the pump from the main power supply.
IMPORTANT: Do not allow the pump to run dry
MAINTENANCE
WARNING: BEFORE CHECKING THE CONDITION OF THE PUMP, ENSURE IT IS UNPLUGGED FROM THE MAIN SUPPLY. IF THE UNIT IS HARD WIRED, ENSURE THE CIRCUIT BREAKER IS OPEN.
This pump should require no maintenance other than regular cleaning.
If the pump starts to show signs of wear or damage, contact your CLARKE dealer
for advice.
CLEANING
- Check the pump installation regularly to ensure the water inlet is clear of leaves or other debris.
- Take extra care to remove any debris from around the impeller.
NOTE: Do not attempt to repair the pump yourself, as you may damage the waterproof seal and invalidate your guarantee. Repairs must be carried out by your CLARKE dealer, or contact the CLARKE Service Department, on 020 8988 7400.
STORAGE
When the pump is not being used for extended periods, clean and dry it
thoroughly and store in indoors. if the pump is left in water, it must be run
at least once a week to prevent it from seizing up.
SPECIFICATIONS
Voltage | 230V-50Hz |
---|---|
Outlet Thread Diameter | 11/2″ BSP |
Power | 400W |
Maximum Head Height | 7 m |
Maximum Depth | 5 m |
Maximum Flow | 116 I/min |
Maximum Water Temperature | 35°C |
Maximum Particle Size | Clean Water Only |
Weight | 4.20 kg |
Cable Length | 10 m |
Dimensions (D x W x H) | 168 x 173 x 260 mm |
TROUBLESHOOTING
PROBLEM | SOLUTION |
---|
PUMP WILL
NOT START| 1. Make sure that the power is switched on.
2. Check fuse (consult an electrician if in doubt).
3. If an extension lead is fitted, check connections (consult an electrician
if in doubt).
4. internal thermal cut-out has not re-set. Leave for 5-10 minutes and try
again.
5. The impeller may be jammed. Disconnect from the mains supply and remove
any objects that may be obstructing the impeller.
6. Water level too low. – Try using the pump in manual operation mode.
7. If the pump still fails to start, consult your CLARKE dealer for advice.
PUMP WILL
START BUT NOT
PUMP| 1. Check that the inlet is not blocked.
2. Check that the outlet is not clogged or obstructed.
3. The head may be too great, i.e. you are trying to lift the water too great
a distance for the pump to cope with. (“Specifications” on page 7).
4. Air bubbles in the pump, produced during immersion.
immerse the pump again, at an angle, and shake it whilst lowering to remove
any air trapped in the system.
5. Impeller may be damaged – Consult your CLARKE dealer.
PUMP WILL
NOT STOP| 1. Sensor may be faulty. Consult your CLARKE dealer for advice.
PUMP STOPS
RUNNING| 1. Thermal overload has operated. Leave for 5-10 minutes and try
again.
2. Pump has run dry, or auto sensor has cut in.
3. A foreign object has jammed the impeller.
PARTS LIST & DIAGRAM
PARTS LIST
1 | Power Cable And Plug | 23-3 | Yellow-green Wire |
---|---|---|---|
2 | Water Sensor | 23-4 | Lug Plate |
3 | Self Tapping Screw | 23-5 | Heat Shrinkable Tube |
4 | Handle | 23-6 | Gasket |
5 | Self Tapping Screw | 23-7 | Bolt |
6 | 0-ring | 24 | Wave Washer |
7 | Customized Self Tapping Screw | 25 | Bearing |
8 | Gasket | 27 | Rotor |
9 | Pump Housing | 28 | Stator |
9-1 | Nylon Secure Pressing Cap | 29 | Bush |
9-2 | Screw | 30 | Gasket |
9-3 | Rubber Clip | 31 | 0-ring |
9-4 | Ribbon | 32 | Aluminum Bushing |
10 | Clip | 33 | 0-ring |
10-1 | Clip | 34 | Front Cover |
11 | Self Tapping Screw | 35 | 0-ring |
12 | Cable Sheath | 36 | Adjustable Washer |
13 | Cable Sheath | 37 | Impeller |
14 | Circuit Board | 38 | Nut |
15 | Cable Gland | 39 | Main Pump Housing |
16 | Cable Gland | 41 | Fairing |
17 | Cable Block | 42 | 0-ring |
18 | Customized Self Tapping Screw | 43 | Stainless Steel Baseboard |
19 | 6uf Capacitor | 44 | Self Tapping Screw |
20 | Lock Block | 45 | Elbow |
21 | Self Tapping Screw | 46 | 0-ring |
22 | Bolt | 47 | Outlet Connector |
23 | Rear Cover | 48 | Mechanical Seal |
23-2 | Gasket | 49 | Protective Ring |
DECLARATION OF CONFORMITY
A SELECTION FROM THE VAST RANGE OF
PARTS & SERVICE:
0208 988 7400
Parts Enquiries
Parts@clarkeinternational.com
Servicing & Technical Enquiries
Service@clarkeinternational.com
SALES: UK 01992 565333 or Export 00 44 (0)1992 565335
Cl arke INTERNATIONAL Hemnall Street, Epping, Essex CM16 4LG
www.clarkeinternationat.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>