JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual

June 6, 2024
JorVet

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction
Manual

The BioVID 4K Ultra HD camera from LW Scientific provides stunning resolution and color for client education and live presentations. Mount the camera to any trinocular C-mount, and you will have access to high-quality, 8 megapixel imaging and 4K video on your monitor or television screen. Save images and videos to the camera’s SD card, or connect the camera to your computer via USB. The BioVID 4K also has an HDMI port for connection to any large HDTV or projector. With a resolution of 3840 x 2160, the BioVID 4K camera will display 4K quality onto any 4K compatible screen. This camera comes equipped with an extremely sensitive Sony IMX334(C) sensor chip to help it maintain 4K resolution and a fast frame rate in low-light and high magnification settings. No matter where you are, the BioVID 4K will ensure a crisp, clear image from the lecture hall to the laboratory.

Unpacking and Setup

The BioVID 4K Ultra HD Camera comes delivered in a box with the following parts. If any parts are missing, please contact your distributor or LW Scientific promptly.

  • HDMI cable
  • 8G SD card
  • Power adapter
  • USB Mouse with 1.3m cable
  • USB cable – 2 meter
  • CD with camera software (PC’s only. Visit the Camera Software page of our website for Mac software.)

Please read and complete the warranty form online at LWScientific.com/warranty_form. The warranty form documents your purchase. Failure to fill out the warranty form may void any warranty claims on the unit.

Setting Up Your Camera

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual -
Setting Up Your Camera

Mounting camera to microscope: Remove all camera components and set them on a secure, clean surface.

Next, take the camera out of the packaging. If your microscope or stereoscope has a trinocular head, simply screw the camera onto the C-Mount. If you have a binocular scope, you will need the optional eye tube adapter (part number MVP- ADAO-ETCM) to allow you to insert the camera into one of the binocular eye tubes.
Insert included SD card straight down into the SD card slot.

For HDMI output:
Once the camera is firmly mounted and secured onto the microscope, plug one end of the included HDMI cable into the top of the camera and the other into your HD TV.

Connect the USB mouse to the USB port on the top of the camera.

Plug the included power cord into the DC12V port on the top of the camera. The LED light on the top of the camera will glow red. Next, press the ON/OFF button once to power on the camera. The LED light will change to blue. Your camera is now ready to use.
*DO NOT LEAVE POWER JACK PLUGGED IN FOR EXTENDED PERIODS OF TIME. Unplug jack when camera is not in use.

For USB output:
Install included software per instructions in the Software Installation section of this manual.
Remove the HDMI Cable and USB mouse and store in a safe place.
Plug one end of the included USB cable into the USB port on the top of the camera and the other into the USB port of your computer.
Plug the included power cord into the DC12V port on the top of the camera.* The LED light on the top of the camera will glow red. Next, press the ON/OFF button once to power on the camera. The LED light will change to blue. Your camera is ready to use.

For Simultaneous HDMI and USB output:
Attach the HDMI cable to your HD TV and the USB cable to your computer.

Bio VIEW Camera Monitor Instructions:
If you purchased the Bio View Monitor for your camera, please follow the below steps to install the unit. If you did not purchase the Bio View Monitor, you can skip this section. Before installing the monitor to your BioVID 4K camera, install camera on your microscope’s trinocular C mount threading.

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual -
BioVIEW Camera Monitor Instructions

Remove the monitor from its packaging and mount the monitor to the camera’s front mounting bracket using the included thumbscrew. Do not overtighten the thumbscrew but ensure you securely tighten it to prevent the monitor from falling off of the camera.

Plug the power supply into the camera and monitor.

Note: The BioView Monitor includes a double-ended power cord. You can plug both the monitor and camera into the two connectors, using only one power adapter for both devices.

If you wish to adjust the viewing angle of the monitor, loosen the thumbscrew on the back of the unit and then adjust the screen to the desired angle. Note that the hinge point has teeth to allow the angle to be locked firmly into position. After selecting the desired angle, retighten the thumbscrew to ensure the monitor does not move. Failure to loosen the thumbscrew while adjusting the viewing angle can break the hinge.

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual - If
you wish to adjust the viewing angle of the monitor

Operation – HDMI Output

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual -
Camera Control Panel

  1. Place a slide on your microscope and bring the specimen into focus.

  2. Make certain your BioVID 4K Camera is installed according to the HDMI directions above and that both the camera and TV are powered on. Toggle through the “INPUT” settings on your TV to ensure that the correct HDMI port is selected. An image will appear on the TV screen.
    NOTE: If the edges of the image are cut off, make certain that your HDMI TV supports 3840×2160 resolution.

  3. Camera Control Panel: Move the USB mouse to the left side of the screen to reveal the Camera Control Panel. (See the image.)

Click the Snap button to save the displayed image to the SD card.

Click the Record Button to save the displayed video to the SD card.

Exposure: Check the box labelled Auto Exposure to let the camera do the work. (You will still be able to adjust the brightness of your image by moving the slider marked Exposure Target.) Uncheck the box to make the other sliders active for manual adjustment of exposure.

White Balance Settings: Global Auto WB: When this setting is chosen, the camera white balances automatically and continuously readjusts as needed.

Manual WB: When this setting is chosen, the R and B sliders are available for adjustment.

ROI WB: When this setting is chosen, a blue rectangle will appear on the screen. (See image below.) Use the USB mouse to drag the rectangle to an area on the image that is white. Turn the wheel on the mouse to adjust the size of the rectangle. The camera will consider the area inside the rectangle as white for white balancing purposes.

Other settings such as Sharpness, Denoise, Saturation, Gamma, and Contrast can be adjusted by moving the sliders.

Tool Bar: Move the USB mouse to the bottom of the TV Screen to reveal the icons below on the Tool Bar.

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual -
Tool Bar

Software Installation

For PC OS:

  1. Insert CD into CD-ROM drive or visit the Camera Software page of the LW Scientific website. Go to “My Computer” and view the files on the CD:JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual - Insert CD into CD-ROM drive
  2. Click “autorun” and the following screen will appear:JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual - Click “autorun” and the following screen will appear
  3. Next, click “Install Application.” Follow the prompts in the Setup Wizard.JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual - Next, click “Install Application
  4. Select the location in which you want the software installed. Click “Install.”JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual - Select the location
  5. When installation is completed, the following window will appear. Click “Finish.”JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual - When installation is completed
  6. The Software should automatically install a short cut on either your desktop or on the start menu. If it does not, look under “All Programs” in the START Menu, and find the LW Scientific folder. Open the software from there, or right click on the icon, and send a shortcut to the desktop for easy access.
  7. Not required, but for easy image organization, create a new folder named “BioVID Images” on your desktop next to your ToupView icon. As images are saved, they will be easy to find in the image folder on the desktop. Other-wise, images can be saved into any folder or client file on the computer or network.
  8. Select “Toupview” icon.
  9. Connect the camera to the computer using the included USB cable. Your computer should bring up a window which reads, “Device driver software installed successfully.”

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual -
Connect the camera to the computer using the included USB
cable

For Mac OS:

  1. Download ToupLite software from the Camera Software page of the LW Scientific website.
    NOTE: Use Apple’s instructions to download Applications that need permission to be installed.

  2. Connect camera to computer, and open ToupLite.

Operation – USB Output

Install your camera per the instructions in Setting Up Your Camera Section:

  1. Start the ToupView software.
  2. To begin capturing images, click on device (XCAM4K8MPA) under “Camera List.”

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual - To
begin capturing images, click on device

  1. At this point, the screen should be showing a live image from the microscope. If not, look at the microscope head and check if there is a pull knob that directs light up to the trinocular head.
    Capture and Resolution: Use the drop-down boxes to select your resolution. Using maximum resolution will slow down the capture rate but will produce larger images, while smaller resolution will allow faster motion while viewing specimens. See image under Step 5.

  2. White Balance: Empty the microscope stage and turn on the light so the camera is viewing an empty illuminated field. Then go to White Balance and click the “White Balance” button.

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual -
White Balance

  1. Most other settings are set to “auto” or to the best setting. Settings for Frame Speed Level or Flip Horizontal/Vertical can be adjusted if needed.
    Capture the image or several images by clicking on the “Snap” button. Capture videos by clicking on the Record button once to begin records and then a second time to end recording.

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual -
Snap Record

  1. Tabs for the captured images will appear across the top of the live view window. You can then rename and save these to the appropriate folder on your computer. The images will appear behind the live view screen. Click on the first tab, labelled “Video” and then the camera number, to return to the live view screen.

General Precautions and Maintenance

Treat your BioVID as you would any high-quality electronic device. Handle it with care, and do not expose it to moisture or extreme temperatures.

Do not touch the chip inside the camera. If you see spots on the screen, there is likely dust on the chip. This can be cleaned by blowing canned air into the camera.

Please do not attempt to open camera case. There are no user serviceable parts inside.

USB Conflicts: When there are a number of devices installed at the same time, unexpected errors can arise. The cause can be insufficient USB bandwidth or too much combined current being drawn by USB devices. To test these conditions you should uninstall and unplug as many other USB devices as possible.

Image viewing problems: If you see only a black screen, ensure that the trinocular port is opened on the microscope. Point the camera towards a window to confirm that the camera is functioning ­ light should appear on the screen (though it will not focus when not installed on a microscope).

Computer does not recognize device: Make sure you have plugged into a USB 2.0 port. Always try to use the same port each time; otherwise the computer will see the camera as a new device when plugged into a new port. If this happens, just follow the wizard again and the camera will work on the new port as well.

Slow frame rate or frozen screen: Select smaller resolution settings. Depending on the age of the computer, the video driver may not support the maximum resolution and speed performance capable by the BioVID camera.

Specifications

JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera Instruction Manual -
Specifications JorVet MKT-7.5.3-L-304.001 BioVID 4K Ultra HD Camera
Instruction Manual - Specifications

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals