METTLER TOLEDO IND360 Ultra Fast Processing Weighing Terminal User Guide

June 6, 2024
METTLER TOLEDO

Quick Guide
IND360

Safety Instructions

Intended Use
The IND360 Automation Terminal is used for weighing. Use it exclusively for this purpose. Any other type of use and operation beyond the limits of technical specifications without written consent from Mettler-Toledo, LLC is considered as not intended.
It is essential for the buyer to closely observe the installation information, product and system manuals, operating instructions and other documentation and specifications. MT’s warranty and any liability are expressly excluded for damages caused by noncompliance with the applicable manuals.
Do not use the terminal in any environment or category other than those specified under Specifications.

Documentation
For further details on system configuration and operation, visit www.mt.com /ind-ind360-downloads. For product compliance information, visit http://glo.mt.com/global/en/home/search/compliance.html.

Safety Warnings
DOWNLOAD and READ the Installation Guide BEFORE operating or servicing this equipment and FOLLOW all instructions carefully.

WARNINGS
FOR CONTINUED PROTECTION AGAINST SHOCK HAZARD CONNECT TO PROPERLY GROUNDED OUTLET ONLY. DO NOT REMOVE THE GROUND PRONG.
THE IND360 IS INTENDED TO BE USED FOR PROCESS CONTROL AND IS NOT APPROVED AS A SAFETY COMPONENT. WHEN USED AS A COMPONENT PART OF A SYSTEM, ANY SAFETY CIRCUITS MUST BE INDEPENDENT OF THE IND360 AND REMOVE POWER FROM THE IND360 OUTPUTS IN THE EVENT OF AN EMERGENCY STOP OR EMERGENCY POWER DOWN.
THE IND360 IS NOT INTRINSICALLY SAFE! DO NOT USE IN HAZARDOUS AREAS CLASSIFIED AS DIVISION 1, ZONE 0, ZONE 20, ZONE 1 OR ZONE 21 BECAUSE OF COMBUSTIBLE OR EXPLOSIVE ATMOSPHERES. FAILURE TO COMPLY WITH THIS WARNING COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.
IND360 MUST NOT BE INSTALLED INTO A DIVISION 2 OR ZONE 2/22 ENVIRONMENT.
DO NOT ACTIVATE POWER OVER ETHERNET (PoE) ON ETHERNET SWITCHES ON THE IND360 NETWORK. ACTIVATING PoE MAY RESULT IN DAMAGE TO THE IND360.
WHEN THIS EQUIPMENT IS INCLUDED AS A COMPONENT PART OF A SYSTEM, THE RESULTING DESIGN MUST BE REVIEWED BY QUALIFIED PERSONNEL WHO ARE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF ALL COMPONENTS IN THE SYSTEM AND THE POTENTIAL HAZARDS INVOLVED. FAILURE TO OBSERVE THIS PRECAUTION COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.
DO NOT INSTALL, DISCONNECT OR PERFORM ANY SERVICE ON THIS EQUIPMENT BEFORE POWER HAS BEEN SWITCHED OFF AND THE AREA HAS BEEN SECURED AS NON-HAZARDOUS BY PERSONNEL AUTHORIZED TO DO SO BY THE RESPONSIBLE PERSON ON-SITE.
ONLY THE COMPONENTS SPECIFIED IN THE IND360 DOCUMENTATION CAN BE USED IN THIS TERMINAL. ALL EQUIPMENT MUST BE INSTALLED IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS DETAILED IN THE INSTALLATION MANUAL. INCORRECT OR SUBSTITUTE COMPONENTS AND/OR DEVIATION FROM THESE INSTRUCTIONS CAN IMPAIR THE SAFETY OF THE TERMINAL AND COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.
BEFORE CONNECTING/DISCONNECTING ANY INTERNAL ELECTRONIC COMPONENTS OR INTERCONNECTING WIRING BETWEEN ELECTRONIC EQUIPMENT ALWAYS REMOVE POWER AND WAIT AT LEAST THIRTY (30) SECONDS BEFORE ANY CONNECTIONS OR DISCONNECTIONS ARE MADE. FAILURE TO OBSERVE THESE PRECAUTIONS COULD RESULT IN DAMAGE TO OR DESTRUCTION OF THE EQUIPMENT AND/OR BODILY HARM.
ONLY PERMIT QUALIFIED PERSONNEL TO SERVICE THE TERMINAL. EXERCISE CARE WHEN MAKING CHECKS, TESTS AND ADJUSTMENTS THAT MUST BE MADE WITH POWER ON. FAILING TO OBSERVE THESE PRECAUTIONS CAN RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.

Specifications and Operator Interface

Specifications

Enclosure Types| DIN Rail mount, ABS plastic with automatic grounding springs at the rear side of the enclosure, the unit also includes a green plastic locking clip.
---|---
Panel-mount stainless steel front panel with a frame which is compatible to the IND331 mounting dimensions. The panel is structured such that the electronics may be mounted with the display or may be remotely mounted on a DIN (Omega) rail.
Harsh environment desk/wall/column-mount type 304L stainless steel enclosure with Versa 100 mounting holes in the rear of the enclosure using. Mounting brackets are exactly the same as the Model IND570.
Dimensions (w × h × d)| DIN-Rail mount: 40 x 135 x 100 /1.6 x 5.1 x 3.9
Panel Mount: 175 x 94 x 16 / 6.9 x 3.7 x 0.6
Harsh Environment: 275 x 85 x 200 / 10.8 x 3.3 x 7.9
Shipping Weight| DIN-Rail mount: 0.5 / 1.1
Panel Mount: 1.7 / 3.7
Harsh Environment: 3.6 / 7.9
Environmental Protection| DIN-Rail mount: IP20 type 1
Panel-mount panel display: IP65
IND360 Harsh Environment model: IP69K.
Operating Environment| −10° to 50° C (14° to 122° F) at 10% to 90% relative humidity, non-condensing
Legal for Trade| −10° to 40° C (14° to 104° F) at 10% to 90% relative humidity, non-condensing
Hazardous Areas| IND360 is not yet certified for used in hazardous areas
AC Input Power (Harsh and panel-mounmodels)| Operates at 100–240 VAC, 49–61 Hz
Peak current at startup: 750 mA
DC Input Power
(DIN Rail mount and Panelmount models)| Operates at 20-28 VDC
1); 12W 2)   1) Power supply short circuit protection time shall be equal or longer than 100ms.
2) 18W when 5 … 8 POWERCELLs are connected
Scale Types| Analog load cells: up to 8×350 Ω or 20×1000 Ω; 1~4mV/V or APW (Automated Precision Weighing) module and high-precision platforms that include Advanced Setup Mode or Up to 8 POWERCELL load cells.
Analog Load Cell
Excitation Voltage| 5 VDC
Automation interface
Update Rate| IND360 analog: 960 Hz
IND360 POWERCELL: 100Hz for 1~4 LCs; 50 for 4~8 LCs
IND360 Precision:  92 Hz
Display| DIN Rail mount version: 1.04” green OLED
Panel mount version: 4.3” color TFT
Harsh version: 4.3” color TFT
Keypad| DIN Rail mount version: 4 keys (Up, Down, Left, Enter); 0.9 mm thick polyester overlay (PET) with 0.178mm thick polycarbonate display lens
Panel mount and harsh version: 5 keys (Up, Down, Left, Right, Enter); 0.9 mm thick polyester overlay (PET) with 0.178mm thick polycarbonate display lens
Communication| Standard Interfaces
Ethernet Port: Ethernet TCP/IP interface for service setup (web interface) and basic control from PC
Optional Automation Interfaces (none or one of the following)
Dual Industrial Ethernet Port for PROFINET and EtherNet/IP which also support Media Ring Profile (PROFINET) and Device Level Ring (EtherNet/IP) Interface for PROFIBUS DP communication
Interface for Modbus RTU communication
Optional Analog and Digital IOs (none or one of the following) 4~20mA Analog Output
4~20mA Analog Output, 3 Discrete Inputs, 4 Discrete outputs, Solid State
5 Discrete Inputs, 8 Discrete Outputs, Solid State
Approvals| Weights and Measures
IND360 Analog and IND360 POWERCELL
Europe: Class , TC11949 T11060
USA: Class Ⅲ n max. 10,000 CC No. 21-002
Canada: Class Ⅲ n max. 10,000 AM-6161
China: Class  n max. 10,000
IND360 Precision
Europe: Class , , TC11949 T11060
USA: Class Ⅲ n max. 10,000 CC No. 21-002
Canada: Class Ⅲ n max. 10,000 AM-6161
Product Safety
UL, cUL, CE, FCC, CB

DIN Rail Version Interface Features

Operator Interface, Front and Top

Display Features

Front Panel and Display Features, Panel-Mount and Harsh Environment Versions

Pushbutton Functions, All Versions

Scale Function Keys, Weighing Mode| DIN| Panel/Harsh| Scale Function Keys, Menu and Data Entry Modes
---|---|---|---
When a container is on the scale, memorize
tare value and display a net zero weight| | | Scroll up in a menu display
Capture a new gross zero reference point| | | Scroll left in a menu display
Clear the current tare value; the display
will revert to the gross weight value| | | Scroll down in a menu display
Transmits data from the terminal; long press enters Operator Menu
[For details on the ePrint function, reference the
User’s Guide]| | | Confirms an entry and/or moves to the next item in a
menu display or to next lower menu level Moves cursor to the right
Select softkey
[Panel and harsh environment versions only]| | | Move to next lower menu level; select data entry field;
confirm value entry.

Operator Menu Icons [Accessible only if terminal is not in Approved Mode]

| Information Recall| Access system information
---|---|---
| Error Message| Display current error messages (e.g. Scale underload)
| Enhanced Resolution| Display weight value with additional decimal place
| Scale Setup| Set capacity and increment; calibrate zero and span; configure filter; reset calibration values
| Application| Enable/disable embedded Application
| Terminal| Display terminal settings, such as serial number
| Communication| Enable/disable web server, PC applications, and ePrint
| Maintenance| Access terminal maintenance functions

Operating Instructions

Weights and Measures Approved Mode
When the terminal is used in metrologically-approved applications, it is sealed with a paper or wire seal. Do not tamper with the seal.
Two DIP switches, 1 and 2, are accessible on the top of the IND360, and inside the IND360 Harsh Environment model’s enclosure. The table below shows the location of the DIP switches and summarizes their functions.

Panel and DIN Rail Mount Enclosures| | | Switch 1| Switch 2| Function
---|---|---|---|---|---
Standard (Automation) Mode
OFF| OFF| Normal operation
OFF| ON| Master reset of all data during transmitter power-up
Harsh Environment Enclosure| |
Approved Mode (for sales to public)
ON| OFF| Legal-for-trade mode; calibration data protected
ON| ON| Reset of all except
calibration (adjustment) data during transmitter power-up

Web Browser Access to IND360 DIN Rail Mount Model
The IND360 can be configured and controlled directly from its front panel interface, or via a web browser interface. The interface is also a diagnostic tool for service purposes. For web browser access:

  • IND360: Web Server must be Enabled in Access Security menu.
  • PC, IND360: physically connected to the same network
  • PC, IND360: IP addresses configured correctly:
    PC: Windows Control Panel | Network and Internet | Connections

IND360: Default – 192.168.0.8

On-Screen Menus
Menu Navigation
Within the Operator Menu, the Scale Function Keys work as follows:

Data Entry, DIN Rail Mount Version
When an on-screen item requires data entry, the Scale Function Keys work as follows:

Accessing and Exiting the Softkeys, Harsh Environment and Panel-Mount Versions

Accessing and Exiting the Operator Menu

Basic Functions

Zero

Tare
Tare Operation

Clear Tare

ePrint

Diagnostics and Maintenance

Common Errors

Overcapacity| Terminal cannot execute commands because the weight on the scale is over the adjusted (calibrated)
capacity. The weight display shows blanked condition:
---|---
Undercapacity| Terminal cannot execute commands because the weight is under the current captured zero. The weight
display will show an under zero condition:
Motion| If motion is detected when a command is received, the IND360 will wait for a no-motion condition. If a
stable (no motion) weight condition is reached, the command is executed. If a no-motion state cannot be
reached, the command is aborted and a “Scale In Motion” error displays.
Failure to Zero
| If pushbutton zero is enabled and the operator presses the ZERO scale function key, these common errors
may occur:
Zero Failed-Range: Gross weight outside the programmed zero range
Zero Failed-Net Mode: zero failed because scale is in net mode
Scale In Motion: zero failed due to motion on scale
If EEE is shown on display, the terminal has not captured a zero reference at power-up
Failure to Print
| When an operator attempts to use the print function, these common errors could occur: ePrint improperly configured Scale In Motion: print failed due to motion on scale
Function Disabled| Error occurs if an operator attempts to access a disabled function.
Access Denied. User
Not Authorized| Occurs if an operator attempts to access an unauthorized function.

Cleaning the Terminal
Use a soft, clean cloth and mild glass cleaner. Do not spray cleaner directly onto terminal. Do not use industrial solvents such as acetone.

www.mt.com/ind-IND360
For more information

Mettler-Toledo
Im Langacher 44 8606 Greifensee Switzerland
Phone 800 438 4511
© 2021 Mettler-Toledo, LLC 30654686 Rev. 00, 01/2021

METTLER TOLEDO IND360 Quick Guide
30654686XXXXXXXX | 00 |01/2021

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals