KEROSENE FORCED AIR HEATER
User’s Manual &
Operating Instructions
MODEL NUMBERS:
REM-45-KFA-B / REM-80T-KFA-B / REM-140T-KFA-B / REM-175T-KFA-B / REM-215T-
KFA-B
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of
your heater. For Example 150812779. Have your Serial Number ready before
calling customer service at
800-641-6996.
DANGER GENERAL HAZARD WARNING: READ AND UNDERSTAND ALL OF THE
INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE
HEATER. Be sure to comply with the instructions and warnings provided with
this heater. Failure to comply can result in fire or explosion that can cause
property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater. If you
need heater info; such as an operating manual, labels, etcetera, contact
Pinnacle Climate Technologies at
800-641-6996.
DANGER NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
WITHOUT ADEQUATE VENTILATION. THIS HEATER IS SUITABLE FOR OUTDOOR USE, AND
INDOOR USE ONLY IN WELL-VENTILATED AREAS. INDOOR USE IS PERMITTED ONLY FOR:
THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER
CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented portable heater that
uses air (Oxygen) from within the area in which it is used. Failure to provide
adequate combustion and ventilation air will result in asphyxiation, carbon
monoxide poisoning, bodily injury or death. Refer to “Ventilation” on Page 6.
SAFETY INFORMATION
WARNING
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. Keep combustibles such as;
building materials, paper, or cardboard a safe distance away from the heater
as recommended by these instructions. Never use the heater in spaces that
contain products such as; gasoline, solvents, paint thinners, dust particles,
volatile or airborne combustibles, or any unknown chemicals. This is an
unvented portable heater. It uses air (Oxygen) from the area in which it is
used. Adequate combustion and ventilation air must be provided. Refer to
“Ventilation” on page 6. Bulk fuel storage should be a minimum of 25 feet (7.6
m) from the heater.
WARNING DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY
UNDERSTAND THIS SAFETY AND OPERATING INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with this
heater can result in death, serious bodily injury, property loss or damage
from the hazards of fire, soot production, explosions, burns, asphyxiation, or
carbon monoxide poisoning. Only persons who can read and understand these
instructions should use or service this heater.
WARNING DOES NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED.
WARNING DO NOT START THE HEATER WHEN THE CHAMBER IS HOT.
WARNING: This product can expose you to chemicals, including lead,
which is known to the State of California to cause cancer and birth defects or
other reproductive harm. For more information go to
www.P65Warnings.ca.gov.
MASSACHUSETTS RESIDENTS : Massachusetts state law prohibits the use of
this heater in any building which is used in whole or in part for human
habitation. Use of this heating device in Massachusetts requires a local fire
department permit (M.G.L.C. 148, Section 10A).
NEW YORK CITY RESIDENTS: The New York City Fire Code prohibits the
storage, handling, and use of kerosene-fueled heaters for space heating. Any
person violating that provision may be punished by a fine up to $10,000 and a
term of imprisonment of up to 6 months.
THE INSTALLATION OF THE EQUIPMENT SHALL BE IN ACCORDANCE WITH THE
REGULATION OF AUTHORITIES HAVING JURISDICTION AND CSA STANDARD B139.
Look for this icon throughout the manual for helpful tips on how to assemble,
use and clean your KFA Heater.
SAFETY INFORMATION (CONT.)
WARNING RISK OF INDOOR AIR POLLUTION!
The products described in this manual are kerosene direct-fired, forced air
heaters. Kerosene forced air heaters are primarily intended for use for
temporary heating of buildings under construction, alteration, or repair.
Direct-fired means that all of the combustion products of the heater enter the
heated space. This appliance is rated at 98% combustion efficiency but does
produce small amounts of carbon monoxide.
DANGER CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
Carbon monoxide is toxic. Humans can tolerate only small amounts of carbon
monoxide and so precautions should be taken to provide proper ventilation.
Failure to provide proper ventilation in accordance with the instructions in
this manual can result in death. People with breathing problems should consult
a physician before using this heater. Early signs of carbon monoxide poisoning
resemble the flu. Symptoms of improper ventilation/carbon monoxide poisoning
are:
Headache • Dizziness • Nausea • Dry Mouth Sore Throat • Burning of Nose
and Eyes
If you experience any of these symptoms: GET FRESH AIR AT ONCE! Have your
heater serviced and check for proper ventilation. Some people are more
affected by carbon monoxide than others. These include pregnant women, those
with heart or lung problems, anemia, or those under the influence of alcohol
or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY FOR: The temporary heating of adequately ventilated buildings or structures under construction, alteration or repair. Provide at least a three-square-foot (2,800 sq cm) opening of outside air for every 100,000 Btu/Hr (29 kW) heater rating. Refer to “Ventilation” on page 6 for further instructions.
****WARNING RISK OF ELECTRIC SHOCK!
ALWAYS use only the electrical power (voltage and frequency) specified on the
model plate of the heater. ALWAYS use only a three-prong, grounded outlet and
extension cord. ALWAYS use only 14 AWG or better extension cords. ALWAYS
unplug the heater when not in use. ALWAYS install the heater so that it is not
directly exposed to water spray, rain, dripping water, or wind. NEVER use
fuels such as gasoline, benzene, paint thinners, or other oil compounds in
this heater. NEVER refill the heater’s fuel tank while the heater is operating
or still hot. This heater is EXTREMELY HOT while in operation. NEVER block air
inlet (rear) or air outlet (front). NEVER use ductwork in front or rear of the
heater. NEVER move or handle the heater while still hot.
WARNING RISK OF BURNS, FIRE, AND EXPLOSION!
NEVER transport heater with fuel in the tank. NEVER use an external fuel tank. Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
| 45-175T-KFA| 215T-KFA
---|---|---
Top| 4 ft. (122 cm)| 4 ft. (122 cm)
Sides| 4 ft. (122 cm)| 4 ft. (122 cm)
Front| 8 ft. (244 cm)| 10 ft. (305 cm)
ALWAYS locate the heater on a stable and level surface. If your heater is equipped with a thermostat, once it is plugged in, it can start at any time in accordance with the thermostat setting.
WARNING CAUTION! HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, ANIMALS, CLOTHING AND COMBUSTIBLES AWAY FROM THE HEATER.
WHAT’S IN THE BOX (45-KFA / 80T-KFA)
WHAT’S IN THE BOX (140T-KFA / 175T-KFA / 215T-KFA)
Tip : Be sure to remove the axle from the side of the Styrofoam packaging.
– Remove the heater and all packaging materials from the shipping carton
Note: Save the box and packaging materials for future storage.
SPECIFICATIONS
Model #| 45-KFA| 80T-KFA| 140T-KFA| 175T-KFA|
215T-KFA
---|---|---|---|---|---
Rating: Btu/Hr / kW| 45,000 / 13.2| 80,000 / 23.4| 140,000 / 41| 175,000 /
51.3| 215,000 / 63
Fuel Consumption: Gal/Hr / L/Hr| 0.35 / 1.32| 0.63 / 2.38| 1.10 / 4.16| 1.34 /
5.07| 1.63 / 6.17
Fuel Tank Capacity: Gallons / Liters| 5 / 19| 5 / 19| 10 / 38| 13 / 49| 13 /
49
Pump Pressure: psi / BAR| 3.0 / 0.21| 4.2 / 0.29| 6.6 / 0.46| 7.5 / 0.52| 9.0
/ 0.62
Volts: AC/Hz| 120VAC / 60Hz| 120VAC / 60Hz| 120VAC / 60Hz| 120VAC / 60Hz|
120VAC / 60Hz
Amps| 1.| 2.| 2.| 27| 3.
Phase| Single| Single| Single| Single| Single
Specifications are subject to change without notice.
FEATURES
ASSEMBLY INSTRUCTIONS (140T-KFA / 175T-KFA / 215T-KFA)
-
Tilt the heater tank backward and attach the wheel support frame by inserting it into the button spring clips at the back of the bottom support frame.
-
Attach the axle supports by inserting them into the button spring clips at the front of the bottom support frame.
-
Insert the axle through the holes in the axle supports.
-
Slide the spacers onto the axle.
-
Slide the wheels onto the axle and secure them with the axle nuts.
-
Attach the rear handle by inserting the handle into the button spring clips at the rear of the top support frame.
-
Check all parts to ensure they are secure before operating the heater.
Fueling The Heater:
Kerosene (K-1)
For optimal performance of this heater, it is strongly suggested that K-1
kerosene be used, especially in temperatures lower than 26°F (-3°C). K-1
kerosene has been refined to virtually eliminate contaminants, such as sulfur,
which can cause a rotten egg odor during the operation of the heater. Using
diesel fuel can cause excess soot production. Do not use Bio-Diesel as this
fuel will damage your heater’s seals and filter.
– CSA certified for use with K-1 kerosene, no. 1 & no. 2 diesel, JP8/Jet A
Fuel, no. 1 and no. 2 fuel oil.
DANGER NEVER REFUELS THIS HEATER WHILE IT IS HOT OR OPERATING. FIRE OR EXPLOSION COULD RESULT.
CAUTION NEVER FILL THE FUEL TANK INDOORS. ALWAYS FILL THE TANK OUTDOORS. BE
SURE THAT THE HEATER IS ON LEVEL GROUND HEN FUELING, AND NEVER OVERFILL THE
TANK.
WARNING DO NOT USE GASOLINE OR CRANKCASE DRAININGS.
DO NOT use any fuel that is not approved above.
– NEVER use fuel such as benzene, alcohol, white glass, camp stove fuel, paint
thinners, or other oil compounds in this heater. THESE ARE VOLATILE FUELS THAT
CAN CAUSE A FIRE OR EXPLOSION.
– NEVER store kerosene in the living space. Kerosene should be stored in a
well-ventilated area outside the living area.
– NEVER store kerosene in direct sunlight or near a source of heat.
– NEVER use kerosene that has been stored from one season to the next.
Kerosene deteriorates over time. OLD KEROSENE WILL NOT BURN PROPERLY IN THIS
HEATER.
OPERATION
NOTE: Kerosene should only be stored in a blue container that is clearly
marked “Kerosene.” Never store kerosene in a red container. Red is associated
with gasoline.
Ventilation:
DANGER CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
– Risk of indoor air pollution and Carbon Monoxide Poisoning. Use heater only
in well-ventilated areas.
– Refer to Safety Information on page 3 for information about Carbon Monoxide
Poisoning.
– ALWAYS provide a fresh air opening in the heated space of at least three
square feet (2,800 sq. cm) for each 100,000 Btu / Hr. (29 kW) of heater
output. Provide a larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
45-KFA | 80T-KFA | 140T-KFA |
---|---|---|
1.4 ft.² | 2.4 ft.² | 4.2 ft.² |
1300 cm² | 2230 cm² | 3902 cm² |
Minimum Ventilation Opening Needed
175T-KFA | 215T-KFA |
---|---|
5.3 ft.² | 6.5 ft.² |
4924 cm² | 6039 cm² |
Starting the Heater: (Ignition)
- Fill the tank with kerosene or other approved fuel until the needle on the fuel gauge points to “F”.
- Replace the fuel cap and tighten firmly.
- Connect the heater to a three-prong (grounded) power source. You must use a three-prong (grounded) extension cord that is at least 6 feet long and is a minimum of 14
AWG rating.
Model 45-KFA:
- Complete steps 1-3 above.
- Move power switch to “On” position. The power indicator light will illuminate and the heater will ignite.
Stopping / Restarting Heater :
– To stop the heater, move the power switch to the “Off” position and unplug
the power cord.
– To restart the heater; wait 10 seconds and follow ignition steps.
TIP: If the heater does not ignite; move the switch to the “Off”
position, check steps 1-3 above and then move the switch to the “On” position.
Models 80T-KFA – 215T-KFA:
- Complete “starting heater ignition” steps 1-3 above
- Turn the thermostat control knob to the desired temperature setting. The thermostat set range is from 40 ºF to 110 ºF.
- Move the power switch to the “On” position. The power indicator light and room temperature display will illuminate and the heater will ignite.
NOTE: 45-80T-KFA models do not have a room temperature display feature.
The room temperature display will indicate the following:
– When the temperature is less than 0 ºF the display says “LO”.
– When the temperature is more than 99 ºF the display says “HI”.
– Between 0 °F and 99 °F the display shows actual temperature.
Stopping / Restarting Heater:
– To stop the heater, move the power switch to the “Off” position and
unplug the power cord.
– To restart the heater; wait 10 seconds and follow ignition steps.
TIP: If the heater does not ignite, the thermostat may be set too low. Turn the control knob to a higher setting until the heater ignites. If the heater does not ignite; move the switch to the “Off” position, check steps 1-3 above and then move the switch to the “On” position.
Long Term Storage:
Models 45-KFA – 80T-KFA:
- Use an approved siphon to drain fuel through the fuel cap opening.
Models 140T-KFA – 215T-KFA:
- Drain fuel through the drain bolt in the bottom of the fuel tank.
- To remove the drain bolt, unscrew counterclockwise.
- Using a small amount of kerosene, rinse and swirl the kerosene inside of the fuel tank, empty the tank fully.
- To replace the drain bolt; push the drain head fully into the drain hole and screw clockwise.
IMPORTANT: Never store leftover kerosene between seasons, using old fuel can damage the heater.
MAINTENANCE
Service:
DO NOT TAMPER WITH THE UNIT. HAVE A COMPETENT SERVICEMAN MAKE ANY NECESSARY
ADJUSTMENTS OR REPAIRS. Use only original equipment parts. The use of
alternate or third-party components can cause unsafe operating conditions and
will void your warranty. We suggest following a maintenance schedule as
follows:
FUEL / FUEL TANK:
Flush tank every 200 hours of operation or as needed. DO NOT flush with water;
use fresh K-1 kerosene only.
AIR FILTERS:
The air intake filter should be replaced or washed with soap and water and
dried thoroughly every 500 hours of operation or less depending on conditions.
The output and lint filters should be replaced every 500 hours of operation or
less depending on conditions. (See Figure 3)
NOTE: Use of diesel fuel may require additional maintenance
FAN BLADES:
Blades should be cleaned at least once per heating season, depending on
conditions. Remove all accumulated dust and dirt with a damp cloth, taking
care not to bend any of the
fan blades. Be sure the blades are dry before re-starting the heater.
FUEL FILTER:
The fuel filter should be cleaned at least twice per heating season. Clean the
filter by rinsing it in clean K-1 Kerosene. Contaminated fuel could make
cleaning the fuel filter necessary immediately.
NOTE: To remove the filter from models 45 – 80T-KFA turn the filter 90º
clockwise. To remove the filter from models 140T – 215T-KFA turn the
filter 90º counter-clockwise. See Figure 2.
THERMISTER PLACEMENT:
Ensure the thermister wire is in the proper place. The wire should be lying on
the bottom shell inside the heater with the plastic end placed under the motor
support/motor and away from the fan blade.
ROTOR:
The rotor with carbon vanes should be evaluated every heating season. The
rotor is behind the air filters. The vanes should be inspected for damage or
wear. The rotor should be inspected for damage, chips, wear, cracks.
Check rotor gap: Remove the rear cover. Loosen the two pump ring screws.
Lift the pump ring upwards. Insert a 0.1 mm feeler gauge and apply slight
downward pressure, enough to offer resistance when attempting to remove the
gauge. Hand-tighten the two pump ring screws. Re-install the End Pump Cover
and the plastic End Filter Cover. Start the heater and adjust to the proper
pump pressure.
WARNING Never service the heater while it is plugged in or hot!
|
---|---
Service (Continued): SPARK PLUG:
Clean and re-gap every 600 hours of operation, or replace as needed. After
removing the spark plug, clean the terminals with a wire brush. Re-gap the
terminals to 0.140” (3.5mm). See Figure 4.
PHOTOCELL:
The photocell should be cleaned using a cotton swab dipped in alcohol or water
at least once per heating season, or more depending on conditions. See Figure
5.
PUMP PRESSURE:
While the heater is operating, turn adjusting screw clockwise to increase,
counter-clockwise to decrease pressure. Correct pump pressure is as follows:
Model Number | Pump Pressure |
---|---|
45-KFA | 3.0 PSI (0.21 BAR) |
80T-KFA | 4.2 PSI (0.29 BAR) |
140T-KFA | 6.6 PSI (0.46 BAR) |
175T-KFA | 7.5 PSI (0.52 BAR) |
215T-KFA | 9.0 PSI (0.62 BAR) |
Tolerance ± 10%
NOZZLES:
Nozzles should be cleaned or replaced at least once per heating season.
Contaminated fuel could make this necessary immediately. To clean dirt from
the nozzle, blow compressed air through the nozzle front. It may be necessary
to soak the nozzle in K-1 kerosene to loosen any dirt particles.
WIRING DIAGRAMS
45-KFA
80T – 215T-KFA
TROUBLESHOOTING GUIDE
Problem | Possible Cause | Solution |
---|
Heater Ignites, but the main PCB shuts
off after a short period of time.
Lamp flickers and LED display shows
“E1”.| 1. Incorrect pump pressure.
2. Dirty input, output or lint filter.
3. Dirty fuel filter.
4. Nozzle is dirty.
5. Photocell lens is dirty.
6. Photocell not installed properly.
7. Photocell is defective.
8. Improper electrical connection
between main PCB and photocell.
9. Improper location of thermister sensor(does not apply to 45-KFA model)
10. Improper electrical connection within the temperature limit switch|
Solution
1. Adjust pump pressure.
2. Clean / replace air or lint filter.
3. Clean / replace the fuel filter.
4. Clean / replace Nozzle.
5. Clean / replace photocell.
6. Adjust photocell position
7. Replace photocell
8. Check wiring connections
(see wiring diagrams on page 10).
9. Check thermister placement
10. Replace temperature limit switch
The heater will not operate or motor
runs for a short time.
Lamp flickers and LED display shows
“E1”.| 1. No kerosene in the fuel tank.
2. Incorrect pump pressure.
3. Corroded spark plug or incorrect plug gap.
4. Dirty fuel filter.
5. Dirty nozzle.
6. Moisture in the fuel tank.
7. Improper electrical connection
between transformer and circuit board.
8. Ignitor wire not connected to spark plug.
9. Defective ignitor.
10. Improper spacing with rotor| 1. Fill tank with fresh kerosene.
2. Adjust pump pressure.
3. Clean / replace the spark plug.
4. Clean / replace the fuel filter.
5. Clean / replace the nozzle.
6. Rinse fuel tank with clean, fresh kerosene.
7. Inspect all electrical connections
(see wiring diagrams on page 10).
8. Re-attach ignitor wire to spark plug.
9. Replace ignitor.
10. Adjust a rotor
The fan does not operate when the heater
is plugged in and the power switch is
in the “ON” position. The lamp is
flickering or an LED display shows
“E1” or “E2”.| 1. Thermostat is set too low (does not
apply to the 45-KFA model).
2. Broken electrical connection
between main PCB and motor.| 1. Rotate thermostat to a higher setting
2. Inspect all electrical connections
(see wiring diagrams on page 10).
The lamp is flickering and the LED display
shows “E3”.| 1. Thermostat switch has failed.| 1. Replace thermostat
switch (see
Wiring diagrams on page 10).
Poor combustion and/or excess
soot production.| 1. Dirty input, output, or lint filter.
2. Dirty fuel filter.
3. Poor quality of fuel.
4. PSI is too high or too low.
5. Dirty nozzle| 1. Clean / replace air or lint filter.
2. Clean / replace the fuel filter.
3. Flush fuel tank and refuel heater.
4. Use proper pressure.
5. Clean / replace the nozzle
The heater does not turn on and the
the lamp is not lit.| 1. Temperature limit sensor has overheated.
2. No electrical power.
3. Fuse is blown.
4. Improper electrical connection between temperature limit sensor and
circuit board.| 1. Push the power switch to “OFF and
allow the heater to cool for 10 minutes. Restart heater.
2. Check power cords for proper connection and test the power supply.
3. Check/replace the fuse.
4. Inspect all electrical connections (see wiring diagrams on page 10).
PARTS LIST
#| Description| 45-KFA| 80T-KFA| 140T-KFA| 175T-
KFA| 215T-KFA
---|---|---|---|---|---|---
1| Drain Bolt| –| –| 70-002-0115| 70-002-0115| 70-002-0115
2| Fuel Gauge| 70-007-0110| 70-007-0110| 70-007-0215| 70-007-0215| 70-007-0215
3| Fuel Filter| 70-003-0100| 70-003-0100| 70-003-0200| 70-003-0200|
70-003-0200
4| Fuel Cap – Large Plastic| 70-006-0140| 70-006-0140| 70-006-0140|
70-006-0140| 70-006-0140
5| Power Cord| 70-034-0100| 70-034-0100| 70-034-0205| 70-034-0205| 70-034-0205
6| Power Switch| 70-038-0100| 70-038-0100| 70-038-0100| 70-038-0100|
70-038-0100
7| Thermostat Control Knob| –| 70-031-0100| 70-031-0100| 70-031-0100|
70-031-0100
8| Air Line| 70-035-0100| 70-035-0200| 70-035-0300| 70-035-0400| 70-035-0500
9| Thermostat Limit Control| 70-019-0100| 70-019-0100| 70-019-0100|
70-019-0100| 70-019-0200
10| Photocell Bracket| 70-010-0101| 70-010-0101| 70-010-0101| 70-010-0101|
70-010-0101
11| Fuel Line| 70-036-1010| 70-036-1010| 70-036-1020| 70-036-1030| 70-036-1040
12| Photocell| 70-016-0100| 70-016-0100| 70-016-0100| 70-016-0100| 70-016-0100
13| Burner Head Assembly| 70-014-0101| 70-014-0101| 70-014-0301| 70-014-0301|
70-014-0301
14| Nozzle Kit| 70-015-0100| 70-015-0205| 70-015-0310| 70-015-0410|
70-015-0500
15| Spark Plug Kit| 70-052-0100| 70-052-0100| 70-052-0200| 70-052-0200|
70-052-0200
16| Motor| 70-021-0500| 70-021-0500| 70-021-0510| 70-021-0520| 70-021-0520
17| Pump Body| 70-020-0101| 70-020-0101| 70-020-0101| 70-020-0401| 70-020-0401
18| Rotor Kit| 70-022-0100| 70-022-0100| 70-022-0100| 70-022-0200| 70-022-0200
19| End Pump Cover| 70-020-0102| 70-020-0102| 70-020-0102| 70-020-0102|
70-020-0102
20| Filter Kit| 70-054-0100| 70-054-0100| 70-054-0100| 70-054-0100|
70-054-0100
21| End Fitter Cover| 70-020-0103| 70-020-0103| 70-020-0103| 70-020-0103|
70-020-0103
22| Pump Adjustment Kit| 70-055-0100| 70-055-0100| 70-055-0100| 70-055-0100|
70-055-0100
23| Capacitor| 70-020-0125| 70-020-0125| 70-020-0200| 70-020-0201| 70-020-0201
24| Fan| 70-024-0100| 70-024-0200| 70-024-0300| 70-024-0400| 70-024-0400
25| Ignitor| 70-037-0350| 70-037-0350| 70-037-0350| 70-037-0350| 70-037-0350
26| Fan Guard| 70-016-0700| 70-016-0700| 70-016-0200| 70-016-0200| 70-016-0200
27| Main PCB Assembly| 70-027-0100| 70-027-0200| 70-027-0300| 70-027-0300|
70-027-0300
28| Fuse| 70-027-0101| 70-027-0101| 70-027-0101| 70-027-0101| 70-027-0101
29| Clip Nut| 70-001-0106| 70-001-0106| 70-001-0106| 70-001-0106| 70-001-0106
30| Air Pressure Gauge| –| 70-025-0100| 70-025-0100| 70-025-0100| 70-025-0100
31| Cord Bushing| 70-033-0100| 70-033-0100| 70-033-0200| 70-033-0200|
70-033-0200
32| Handle| 70-001-0103| 70-001-0103| –| –| –
33| Rear Handle| –| –| 70-041-0725| 70-043-0600| 70-043-0600
34| Wheel Support Frame| –| –| –| 70-041-0760| 70-041-0760
35| Wheel Axle| –| –| 70-041-0115| 70-041-0205| 70-041-0205
36| Wheel| –| –| 70-041-1400| 70-041-1400| 70-041-1400
37| Wheel Nut| –| –| 70-041-0550| 70-041-0550| 70-041-0550
38| Hardware Kit (not pictured)| 70-056-0100| 70-056-0100| 70-056-0210|
70-056-0210| 70-056-0210
39| Cord Wrap| 70-032-0100| 70-032-0100| 70-032-0200| 70-032-0200| 70-032-0200
40| Motor Supporter| 70-020-0600| 70-020-0600| 70-020-0610| 70-020-0610|
70-020-0610
41| Axle Frame| –| –| 70-041-0735| 70-041-0735| 70-041-0735
LIMITED WARRANTY
Pinnacle Climate Technologies, Inc. warrants this heater to the original
retail purchaser only, to be free from defects in material and workmanship for
a period of one (1) year from the date of initial purchase. This product must
be properly installed, maintained, and operated in accordance with the
instructions provided.
Pinnacle Climate Technologies, Inc. requires reasonable proof of your
date of purchase from an authorized retailer or distributor. Therefore, you
should keep your sales slip,
invoice, or canceled check from the original purchase. This Limited Warranty
shall be limited to the repair or replacement of parts, which prove defective
under normal use and service within the warranty period, and which Pinnacle
Climate Technologies, Inc. shall determine at its reasonable discretion. This
warranty does not apply to products purchased for rental use.
This Limited Warranty does not cover any failures or operating difficulties
due to normal wear and tear, accident, abuse, misuse, alteration,
misapplication, improper installation or improper maintenance and service by
you or any third party. Failure to perform normal and routine maintenance on
the heater, shipping damage, damage related to insects, birds or animals of
any kind, and damage due to weather conditions are also not covered. In
addition, the Limited Warranty does not cover damage to the finish, such as
scratches, dents, discoloration, rust, or other weather damage, after
purchase. All transportation costs for the return of damaged products or parts
will be the responsibility of the purchaser. Upon receipt of the damaged item,
Pinnacle Climate Technologies, Inc. will examine the item and determine if
defective. Pinnacle Climate Technologies, Inc. will repair or replace and
return the item, freight pre-paid. If Pinnacle Climate Technologies, Inc.
finds the item to be in normal operating condition, or not defective the item
will be returned freight collect. This Limited Warranty is in lieu of all
other express warranties. Pinnacle Climate Technologies, Inc. disclaims all
warranties for products that are purchased from sellers other than authorized
dealers or distributors. AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS WARRANTY
EXPIRES, Pinnacle Climate Technologies, Inc. DISCLAIMS ANY AND ALL IMPLIED
WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle
Climate Technologies, Inc. SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR
ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, OR
CONSEQUENTIAL DAMAGES. Pinnacle Climate Technologies, Inc. assumes no
responsibility for any defects caused by third parties. This Limited Warranty
gives the purchaser specific legal rights; a purchaser may have other rights
depending upon where he or she lives. Some states do not allow the exclusion
or limitation of special, incidental, or consequential damages, or limitations
on how long a warranty lasts, so the above exclusion and limitations may not
apply to you. Pinnacle Climate Technologies, Inc. does not authorize any
person or company to assume for it any other obligation or liability in
connection with the sale, installation, use, removal, return, or replacement
of its equipment, and no such representations are binding on Pinnacle Climate
Technologies, Inc. Always be sure to specify the model number and serial
number when making any claim with Pinnacle Climate Technologies, Inc. For your
convenience, use the space provided below to list this information.
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of
your heater. It will be a series of 9 digits. For Example 131234956. Have your
Serial Number ready before calling customer service at
800-641-6996.
Model #:____
Serial #:____
Date of Purchase: ____
Sauk Rapids, MN 56379 USA
• Toll Free 800-641-6996
Fax: 320-251-2922
• Web: www.remingtonheater.com
• Email: info@pinnacleclimate.com