MARZAN SECURITY Electronic Lock with Keypad Round User Manual
- June 6, 2024
- MARZAN SECURITY
Table of Contents
MARZAN SECURITY Electronic Lock with Keypad Round
Copyright
This publication, including all photographs, and illustrations, is protected
under international copyright laws, with all rights reserved. Neither this
manual, nor any of the material contained herein, may be reproduced without
written consent of the author. © Copyright 20201
Disclaimer
The information in this document is subject to change without notice. The
manufacturer makes no representations or warranties with respect to the
contents hereof and specifically disclaims any implied warranties of
merchantability or fitness for any particular purpose. The manufacturer
reserves the right to revise this publication and to make changes from time to
time in the content hereof without obligation of the manufacturer to notify
any person of such revision or changes.
General
Code entry
The electronic lock works with a 6 to 8 digit code. Each input is confirmed by a beep and the green light illuminates.
After entering a valid code, you hear two short signals and the green light flashes twice. If the code is invalid, you will hear a long signal and the red light will flash.
Opening the safe
If you use the safe for the first time, open the lock with the factory code
(ON – factory code 123456 – ENTER).
The lock operates with a master code and a user code.
After entering the code unlock the door within five seconds using the handle.
If you do not open the lock within five seconds, the lock closes again
automatically.
Closing and locking safe door
Close the door and turn handle fully to closing position. The lock is secured. You can test whether the lock is locked by turning the handle to the open position.
Blocking
If incorrect codes are entered three times in a row, the keypad blocks automatically for five minutes. The red light flashes every few seconds during that period. Entering a wrong code twice after the blocking period will start a new delay time of five minutes.
Safety reference
Once you start using the safe, change the standard factory code into your own personal access code immediately. When choosing a code, avoid obvious combinations such as numbers related to your birth date, part of your telephone number or postcode. Remember the code and keep it to yourself. If you feel the need to write it down, keep it in a safe place.
Symbols
|
Meaning
---|---
| Green light is on
| Sound signal
| Red light is
on
Master and user code
Setting the master code
Make sure that the safe door is open when you change the code. To open the safe press ON, key in the master code (or factory code 123456 if you use the lock for the first time) and press ENTER.
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/7-397-550x125.png)
2.| Press Enter| Enter|
3.| Press 1| 1|
4.| Press Enter| Enter|
| Key in the master code (or factory code, 123456 if you use the lock for the first time)|
123456
|
6.| Press Enter| Enter|
7.| Key in the new master code, e.g. 567891| 567891|
8.| Press Enter| Enter|
9.| Repeat the new master code, e.g. 567891| 567891|
10.| Press Enter| Enter|
The new master code is now set. If the new code is not accepted, you hear a long signal and a red light flashes. In that case, start again at step 1 for changing the master code. After changing the code, it is best to test the new code several times with the door open.
Setting the user code
You can only set a user code after changing the master code from the factory
code to your personalized one.
Please note – the user code may not be the same as the master code!
Make sure that the safe door is open when you change the code (ON – master
code – ENTER).
Up to 9 users can be programmed. They receive an user ID. For exemple, user 1
receives user ID “1”.
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/7-397-550x125.png)
2.| Press Enter| Enter|
3.| Press 2| 2|
4.| Press Enter| Enter|
5.| Key in a user ID (choose between 1-9), e.g. 1| 1|
6.| Press Enter| Enter|
7.| Key in the master code, e.g. 567891| 567891|
8.| Press Enter| Enter|
9.| Key in the new user code, e.g. 111111| 111111|
10.| Press Enter| Enter|
11.| Repeat the new user code, e.g. 111111| 111111|
12.| Press Enter| Enter|
The new user code is now set. If the new code is not accepted, you hear a long signal and a red light flashes. In that case, start again at step 1 for setting the user code. After setting the code, it is best to test the new code several times with the door open.
Changing the user code (by a user, without the master code.)
Please note – the user code may not be the same as the master code!
Make sure that the safe door is open when you change the code (ON – user code
– ENTER).
Up to 9 users can be programmed. They receive an user ID. For exemple, user 1
receives user ID “1”.
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/7-397-550x125.png)
2.| Press Enter| Enter|
3.| Press 3| 3|
4.| Press Enter| Enter|
5.| Key in a user ID (choose between 1-9), e.g. 1| 1|
6.| Press Enter| Enter|
7.| Key in the current user code, e.g. 111111| 111111|
8.| Press Enter| Enter|
9.| Key in the new user code, e.g. 222222| 222222|
10.| Press Enter| Enter|
11.| Repeat the new code, e.g. 222222| 222222|
12.| Press Enter| Enter|
The new user code is now set. If the new code is not accepted, you hear a long
signal and a red light flashes.
In that case, start again at step 1 for changing the user code. After changing
the code, it is best to test the new code several times with the door open.
Deleting the user code
Only the master code can delete a user code.
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/7-397-550x125.png)
2.| Press Enter| Enter|
3.| Press 0| 0|
4.| Press Enter| Enter|
5.| Key in a user ID (choose between 1-9), e.g. 1| 1|
6.| Press Enter| Enter|
7.| Key in the master code, e.g. 567891| 567891|
8.| Press Enter| Enter|
Only the master code remains valid. If the user code deletion is unsuccessful, you hear a long signal and a red light flashes. In that case, start again at step 1 for deleting the user code.
Opening delay and opening window
Opening delay 1-99 minutes:
The waiting time before you can open the lock.
Opening window 1-9 minutes:
You have to enter the code again to open the safe during this window (the
period in which you can open it)
Programming opening delay and opening window
You can only program an opening delay and window by using the master code.
Make sure that the safe door is open when you start programming an opening
delay and window
(ON – master code – ENTER)
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/7-397-550x125.png)
2.| Press Enter| Enter|
3.| Press 6| 6|
4.| Press Enter| Enter|
5.| Key in the master code, e.g. 567891| 567891|
6.| Press Enter| Enter|
7.| Enter the opening delay using two digits, e.g. 5 minutes| 05|
8.| Enter the opening window using single digit, e.g. 1 minute| 1|
9.| Press Enter| Enter|
Opening with opening delay and opening window
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | **![](https://manuals.plus/wp- |
content/uploads/2022/02/7-397-550x125.png)
2.| Key in the user or master code, e.g. 567891| 567891|
3.| Press Enter| Enter|
4.| The opening delay time starts, the red light illuminates every 5 seconds|
|
5.| The opening delay time has elapsed, you hear an audible alarm| | **
6.| The opening window period starts, you hear an audible signal and the red
lamp illuminates every 5 seconds| |
7.| Key in the user or master code, e.g. 567891| 567891|
8.| Press Enter| Enter|
9.| Open the handle within 5 seconds, the safe is open.| |
Deactivating opening delay
Open the lock, following the steps described in 3.2.
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/7-397-550x125.png)
2.| Press Enter| Enter|
3.| Press 6| 6|
4.| Press Enter| Enter|
5.| Key in the master code, e.g. 567891| 567891|
6.| Press Enter| Enter|
7.| Press 000| 000|
8.| Press Enter| Enter|
The opening delay and the opening window are now deactivated.
Changing the opening delay and/or opening window
Firstly, deactivate the pre-set opening delay and window (see 3.3).
Then follow the steps in 3.2 to set new opening delay and window times.
Switching the audible opening window signal off or on
You can only switch the audible signal on or off with the master code.
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/7-397-550x125.png)
2.| Press Enter| Enter|
3.| Press 5| 5|
4.| Press Enter| Enter|
5.| Key in the master code, e.g. 567891| 567891|
6.| Press Enter| Enter|
Dual code (4 eyes principle)
Programming dual code
Make sure you programmed at least one user code (see 2.2). Make sure that the safe door is open when you start programming the dual code (ON – master code – ENTER).
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/7-397-550x125.png)
2.| Press Enter| Enter|
3.| Press 7| 7|
4.| Press ENTER| Enter|
5.| Key in the master code, e.g. 567891| 567891|
6.| Press Enter| Enter|
The double code function is now activated.
Opening with dual code
The lock opens now after entering the master code (ID 0) and the user codes as programmed in chapter 4.1.
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/8-356-550x89.png)
2.| Key in user ID, e.g. 1| 1|
3.| Press Enter| Enter|
4.| Key in user code corresponding to user ID 1, e.g. 111111| 111111|
5.| Press Enter| Enter|
6.| Key in user ID, e.g. 2| 2|
7.| Press Enter| Enter|
8.| Key in within 1 minute user code corresponding to user ID 2, e.g. 222222.|
222222|
9.| Press Enter| Enter|
Deactivating dual code
Step | Action | Key | Signal |
---|---|---|---|
1. | Press ON | ON | ![](https://manuals.plus/wp- |
content/uploads/2022/02/8-356-550x89.png)
2.| Press Enter| Enter|
3.| Press 8| 8|
4.| Press Enter| Enter|
5.| Key in the master code, for example 567891| 567891|
6.| Press ENTER| Enter|
The double code function is now deactivated.
Power supply
Changing the battery
As soon as the battery is almost empty (and the voltage becomes too low), the red light will flash 5 times and a warning signal will sound several times when the door is opened. This is the warning that you need to change the battery.
Do not use rechargeable batteries, only high quality 9-volt batteries.
Unscrew the battery cover on the inside of the door. Remove the battery,
insert a new battery, and fit the cover in place again. Then test opening and
closing a few times with the door open.
Emergency power supply
There is an emergency power supply facility on the keyboard, in case the fitted battery becomes completely discharged. Remove the plastic cover plate with a screwdriver. While holding a 9-volt block battery firmly against the ‘+’ and ‘-’, carry out the normal opening procedure. Then you can replace the empty battery.