ITECH IT6700 Digital Control Power Supply User Manual
- June 6, 2024
- iTech
Table of Contents
- ITECH IT6700 Digital Control Power Supply User Manual
- WARNING
- Certification
- Notice
- Warranty
- Limitation of Warranty
- Compliance Statements
- Safety Symbols
- About IT6700
- Example:
- Function
- Panel Layout
- Instrument Size Introduction
- Quick Start Check out
- Setting the current
- Enable output
- Step value for Cursor Position
- Check the set voltage and current value
- Key lock function
- OVP function
- OCP function
- NOTE
- Key sound (BEEP)
- Power address (ADD)
- Store group setting (GRP)
- CV, CC working mode of power supply
- Battery charging protection
- Faulty disposal
- If the outputs is disabled:
- Specifications
- Specs
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ITECH IT6700 Digital Control Power Supply User Manual
WARNING
Safety Regulations
To avoid electrical shock, do not open the cabinet. Refer servicing to
qualified personnel only.
To avoid injuries, always disconnect power, discharge circuits, and
remove external voltage sources before touching components.
KEEP AWAY FROM LIVE CIRCUITS.
We cannot accept responsibility for any direct or indirect financial damage
or loss of profit that might occur when using the power supply.
The instrument chassis and cover must be connected to an electrical
ground.
Certification
We certify that this product met its published specifications at time of shipment from the factory.
Notice
The information contained in this document is subject to change without notice.
Warranty
This hardware product is warranted against defects in material and workmanship for a period of ONE year from date of delivery. IT6700 power supply for use with a hardware product and when properly installed on that hardware product, are warranted not to fail to execute their programming instructions due to defects in material and workmanship for a period of 90 days from date of delivery.
During the warranty period our company will either repair or replace products which prove to be defective. Our company does not warranty that the operation for the software firmware or hardware shall be uninterrupted or error free. For warranty service, with the exception of warranty options, this product must be returned to a service facility designated by our company. Customer shall prepay shipping charges by (and shall pay all duty and taxes) for products returned to our place for warranty service. Our company shall pay for return of products to Customer.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or
inadequate maintenance by the customer, customer-supplied software or
interfacing, unauthorized
modification or misuse, operation outside of the environmental
specifications for the product, or improper site preparation and
maintenance.
Compliance Statements
Disposal of Old Electrical & Electronic Equipment (Applicable in the
European Union and other European countries with separate collection systems)
The ITECH product you have purchased is subject to Directive 2002/96/EC
of the European Parliament and the Council of the European Union on waste
electrical and electronic equipment (WEEE) and, in jurisdictions adopting that
Directive, is marked as being put on the market after August 13, 2005, and
should not be disposed of as unsorted municipal waste. Please utilize your
local WEEE collection facilities in the disposition of this product and
otherwise observe all applicable requirements.
Safety Symbols
Connect it to safety earth ground using the wire recommended in the user’s
manual.
High voltage danger
The symbol on an instrument indicates that the user should refer to the operating instructions located in the manual
About IT6700
With widest voltage and current range, IT6700 digital DC power supplies are
applied in many fields.
Take IT6720 for example, with max power 100W and output adjustable in 60V/5A,
auto control voltage/current slew rate, power rate up to three times rapid
than other similar products, a unit can
replace three models (60V1.6A/ 32V3A/ 20V*5A), reduce your repeat
investment.
Example:
When you set the output voltage as 60V, because the max power of IT6720 is
100W, so the max output current is 100W/60V=1.6A.
When you change the output voltage to 30V, the output current is
100W/30V=3.2A.
Calculate according to the above way when the output voltage is 20V, the
output current should be 5A, but as the max rating current of IT6720 is 8A, so
the final max output current is 5A.
Function
- Fully digital control
- ◼ High resolution 10mV/1mA in Full range
- ◼ Low ripple and noise
- ◼ Software calibration
- ◼ Bright and easy to read display (VFD)
- ◼ Constant current and constant voltage output
- ◼ Selectable remote control keypads
- ◼ High reliability OVP/OCP/OTP protection
- ◼ Output on/off control
- ◼ Best performance /price ratio
- ◼ Storage for 4*100 preset voltage and current output
Panel Layout
Instrument Size Introduction
Quick Start Check out
Confirm whether the power supply has been destroyed in transportation, if
there is any flaw, please contact the vender.
Confirm whether the AC input voltage of IT6700 comply with the standards of
your country or region.
Note: If switching input voltage, operate through the back panel switch
(110V/220V).
After the check of the above matters, power on by press
Setting the current
Check out Press to light up the voltage setup indicator B. It means IT6700 is
in voltage set mode, shown as fig 1.
Preset voltage Press light up the voltage setup indicator . Now the voltage
will rise/decline 1V once you rotary the knob . Set the voltage to 12V. A B
Step indicator B
Press to light up the current setup indicator A. IT6700 is in current set
mode, shown as fig 1. D V/A Press to adjust the setup indicator to . Now the
current will rise/decline 1V once you rotary the knob . Set the current to 4A.
Enable output
Press to enable the IT6700 output. Voltage and current settings will be wink
for three seconds,and after that , the display value of numerical display will
change from the set value to actual measured voltage and current value. On/Off
On/Off Power off lights will be turned off which means the power is in output
state.
Press again, you will shut power supply’s output.
Step value for Cursor Position
Cursor position | Step voltage | Step current |
---|---|---|
A | —— | 1A |
B | 1V | 0.1A |
C | 0.1V | 0.01A |
D | 0.01V | 0.001A |
Check the set voltage and current value
The power supply usually displays the actual voltage and current values.
When you want to check the preset voltage and current values, the unit will
display automatically settings, press twice, the settings will be displayed
for three seconds.
Key lock function
This function can prevent error operation by unauthorized person. Press ,
after the was lit on, press , will be lit on, which means all keys on the
panel except
and . Repeat above operation, key lock function will be disabled.
OVP function
Press , and press for three seconds, now the panel displays OVP, shown as fig 4. Shift D V/A Use and to set OVP value.
OCP function
Press to enter into OCP setting interface after setting OVP value, use and to set the OCP value.
NOTE
If the OVP and OCP settings are lower than the actual voltage/current value,
the output of power supply will be turned off.
The default settings of IT6720 are OVP=61V, OCP=5.1A;IT6721 OVP=61V, OCP=8.1A.
Key sound (BEEP)
Press to enter the BEEP setting Interface after finished the OCP setting,
select the ON/OFF state with the knob . ON indicates there is key sound, OFF
means no.
\
Power address (ADD)
Press to enter the ADD setting interface after finishing the BEEP setting, select the and to enter store address setting. ADD range: 0~30,press to confirm。
Store group setting (GRP)
Press to enter into GRP interface after setting the OCP value, use and to
select store group. C A B
IT6700 allows customers to store 100 groups with A/B/C/D four set value for
every group. Press to confirm the chosen group and end the setup mode.
CV, CC working mode of power supply
The output current value is determined by output voltage of power supply and electronic load’s resistance. Only when the actual current value is lower than the setting current value, can power supply work in CV mode and the will CV indicator light be lit. If output current is higher than the setting value, then power supply will function in CC mode. And the CC indicator light will be lit.
Battery charging protection
WARNING
Pay attention to the positive and negative terminals when connecting the
battery. If the battery is connected reversely to the power supply, it will
result in damage to the power supply.
When using the power supply to charge the battery, a diode and a fuse must be
connected in series with the output as shown in the following figure to
protect the circuit . The detailed methodology is shown as follows.
The role of the diode and the fuse in the above figure is described as below.
- The role of the diode is to block any reverse voltage and current flow to the battery to protect the power supply and prevent the internal parts from The series diode can also avoid the condition that the battery discharges due to the internal resistive load of the power supply in the power-off or output-off state.
When selecting the diode, the user should consider the following notes. The current capacity of the diode should be 110% of the rating current of the battery at least. When setting the input voltage of the battery, the user need to consider the threshold voltage of the diode. The typical threshold voltage of a silicon diode is 0.6 V to 0.7 V. The reverse breakdown voltage of the diode should be more than twice the rating voltage of the battery. The user also need to consider the power of the diode and add a heat sink when necessary
- The role of the fuse is to interrupt the current by melting the metal wire in it when the current rises to a certain value, thereby protecting the
When selecting the fuse, the user should consider the following notes. The rating current of the fuse should be 150% to 200% of the maximum current of the battery and be less than 150% of the maximum output current of the power supply.
Faulty disposal
If the outputs is disabled:
- Check whether voltage and current settings are zero, if so, reset voltage and current value.
- Check whether the indicator is lit on, if so, press to enable the outputs.
- Check whether the indicators are lit on, if so, please resetaccording to the mentioned OVP/OCP/OCP means.
If the keypad is disabled, check whether the indicator is lit on, if so, unlock the keypads as the above means.
Specifications
Specs
Specifications
Output Rating | Voltage | 0~60V | 0~60V |
---|---|---|---|
Current | 0~5A | 0~8A | |
Power | 100W | 180W | |
Load Regulation | Voltage | <0.01%+3mV | <0.01%+5mV |
Current | <0.01%+3mA | <0.01%+5mA | |
Line Regulation | Voltage | <0.01%+3mV | <0.01%+5mV |
Current | <0.1%+3mA | <0.1%+5mA | |
Programming Accuracy | Voltage | <0.05%+10mV | <0.05%+10mV |
Current | <0.2%+2mA | <0.3%+5mA | |
Read back Accuracy | Voltage | <0.05%+10mV | <0.05%+10mV |
Current | <0.1%+2mA | <0.3%+5mA | |
Ripple | Voltage | <2.0mV rms | <5.0mV rms |
Current | <5mA rms | <8mA rms |
Maximum input
apparent power
| | 300VA| 700VA
Dimension| WHD| 88175282(mm)| 88175282(mm)
Weight| Net| <2.5Kg| <3.5Kg
Contact US
Thank you for purchasing ITECH products. If you have any doubt about this product, please
contact us as follow.
- Please refer to the CD-ROM of related user’s manual in package.
- Click itechate.com or scan the right two-dimension code to visit the ITECH website.
- Send E-mail to fae@itech.sh or dial the service hot-line in China: 4006025000
- Select the most convenient contact method for further
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>