Neusoft Group GLM1908TB In-Vehicle Telematics Module Instruction Manual

June 6, 2024
Neusoft Group

In-veh hicle T Telemat tics Mo GL LM1908T TB prodduct specifiodule cationn

Please read this manual carefully before using the product and keep it properly.

Important safety information

  • Please read this instruction before using the equipment

  • Please keep these instructions

  • Please notice all warnings

  • Please follow all instructions

  • Please ensure the cables are not trampled or squeezed, especially the connection point between the harness and the equipment

  • Please use the attachment specified by the supplier.

  • Any damage of the device, it must be repaired by professional maintenance personnel in time.

  • The product must be installed by authorized personnel.
    Warning The sign marks important instructions. Lack of attention may result in serious injury or death.

  • Forbid to plunge the equipment into fire.

  • Avoid the equipment wet or rained.

  • Forbid to remove or refit.

  • Must be used in 12V automotive voltage

Warning The sign marks important instructions. Lack of attention may result in serious injury or death.

  • Forbid to plunge the equipment into fire.
  • Avoid the equipment wet or rained.
  • Forbid to remove or refit.
  • Must be used in 12V automotive voltage

Notice The sign marks notice instructions. Lack of attention may result in personal injury or product damage.

  • If there is any problem, please stop using it immediately. Otherwise, it may cause personal injury or damage to the product
  • Replacement with the wrong type of battery is a risk of explosion. Be sure to dispose of the used battery according to the instructions.
  • Please send the product back to the authorized distributor or service center for repair.

Function description

Data collection: Support 1CH CAN data acquisition channel according to OEM

  • Data report : Report the real time data of the vehicle periodically for normal working conditions.
  • Warning information: Forward alarm information based on OEM requirements.
  • Remote control: Remote configure the parameters abide by local standard, support OEM to customize remote control interface.
  • Remote inquiry: Support OEM to customize remote control interface, the functions include remote dashboard, journal log, and remote vehicle status inquiry.
  • Power management: It is customized based on OEM normal power management.
  • Software upgrade: Support local and remote(online) upgrade
  • Vehicle localization : Support vehicle GPS information providing and tracking service based on OEM requirement.
  • e-Call : Support make e-Call when an emergency event is triggered, either manually or automatically,

Parameters

c tegory Sub-classif cation specification unit
Powersupply Standby current <=4.0 mA
Max current <=1000 mA
Rated current 500 mA
--- --- --- ---
Rated voltage DC+12 V
Motion voltagerange 9-16 V
Rated power 6 W
Temperature working temperature range -40~85
battery working temperature range 0~50
storage temperature range -40~85
Electrical CAN channel volume 1
communication manner 4G(SIM card)
carrier KPN
backup battery working duration >10min(normal temperature) min
Mechanical dimension 183128.428.5 mm
weight <300 g

Component list
 EElectric vehiicle monitoring terminalhost 1 set

Neusoft Group GLM1908TB In-Vehicle Telematics Module -
Component

Piccture 1electric vvehicle monitoring terrminal

Name harm and co mful subs ontent l stances abeling of tox ic and

| Toxic substance or element
---|---
| | | | | polybr|
Compone nt name| lead (PB)| merc ury (Hg)| cadm ium(Cd)| hexavalen t chromium (Cr(VI))| ominat ed biphen| ** PBDE
| | | | | yls|
| | | | | (PBB)|
Circuit board compone nt| ×| ○| ○| ○| ○| ○
shell compone nt| ×| ○| ○| ○| ○| ○
attachment| ×| ○| ○| ○| ○| ○
○ :Meaning the content of the toxic and harmful substance in the part is below the limitation specified in SJ/ T11363-2006 standard.
×:Meaning the content of the toxic and hazardous substance in the part exceeds the limitation specified in the SJ/ T11363-2006 standard.
All parts marked with “X” are in compliance with the EU RoHS regulation (2002/95/ CE code)
Notice:The** environmental protection service life depends on the product normal working temperature and humidity and other conditions.

Legal and regulatory standards DB31 T634–2012
statements Due to continuous product updates. we reserve the right to make changes and modifications to our products without prior notice.
Neusoft ,-is a registered trademark held by Neusoft. We reserve all rights. Counterfeiting will be prosecuted. All other designs belong to the owner.

Product installment
This product only provides the monitoring terminal of the vehicle. and the connector on the side of the vehicle is the standard connector of vehicle regulation level. The installation location and mode are defined by the vehicle manufacturer.

Main connector PIN definition

Product operation
After the monitoring terminal of electric vehicle is connected with the vehicle. the terminal can automatically bind with the vehicle after the igniticm, and report the monitoring data to the monitoring backend. Users can monitor the running condition of the vehicle by the operation of the backend website.

Pin No.

| Name| Direction|

Function

---|---|---|---
1| SOS Call Button| Ananlogue in|
2| SOS_CallDiagnostic| Ananlogue out|
3| SOS_Light| Ananlogue out|
4| B_call_lght| Ananlogue out|
5| Power_12T| Ananlogue in| +30 (permanent power)
6| Ground| | Groud
7| NC| |
8| NC| |
9| Backup_Speaker+| Ananlogue out|
10| Backup Speaker-| Ananlogue out|
11| CAN( -)| Ananlogue in/out| Body CAN low
12| CAN(+)| Ananlogue in/out| Body CAN high
13| OnCall Ground| Ananlogue out|
14| Backup M c-signal| Ananlogue in| Connected tc the shield of tie coaxial cable
15| Backup Mc+signal| Ananlogue in| Microphone 4 signal and phantom feet –
16| NC| |
17| Impact input trigger| Ananlogue in| Hardwired SFS impact input trigger
18| NC| |
19| NC| |
20| NC| |
21| NC| |
22| NC| |

All rights reserved. All pictures and texts in this manual, without authorization are strictly forbidden to be used in whole or in part by any means.
This manual is a random manual and shall not be resold or distributed.

Neusoft ffi
Beyond Technology
Manufacturer : Neusoft Group (Dalian) I i an) co. , LTD.

Address : No. 901 Huangpu Road, Dalian China, 116085.
Manufacture : DAESUNG ELTEC (0 i ngdao)
Address : Qingdao, China Version number : Ver1. 00

FCC Warning This device complies with part 15 of the FCC rules.

Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

o Reorient or relocate the receiving antenna.
o Increase the separation between the equipment and receiver.
o Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
o Consult the dealer or an experienced radio/TV technician for help.

Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals