MedLite ID IDA01US Primary Medication Line Safety Device Instructions
- June 6, 2024
- MedLite ID
Table of Contents
MedLite ID IDA01US Primary Medication Line Safety Device
Primary Medication Line Safety Device
FOR PATIENT SAFETY
this product is intended for use with primary medication line only.
Warning:
Attach MedLite ID to primary medication line prior to connecting IV to
patient.
-
Open the MedLite ID package and remove the three devices from the pack. Removing plastic strip will activate device.
-
Prior to connecting the primary medication line to the patient, apply MedLite ID devices (see figure) by running the infusion tubing through the tubing grooves on the device.
-
Inspect tubing for twists or kinks, vbthen close the clamshell door until it clicks.
-
Press one of the attached devices to activate the lights for all three devices within a given set.
Warning:
To maintain proper flow check for pinched or twisted tubing before closing
clamshell.
FOR PATIENT SAFETY
This product is intended for use with primary medication line only.
Warning:
Attach MedLite ID to primary medication line prior to connecting IV to
patient.
Warning:
To prevent reduced or obstructed infusion set flow, be sure that when
closing the MedLite ID clamshell over the primary medication line that the
tubing is not pinched or twisted.
Directions
- Open the MedLite ID peel pack and remove the three devices from the pack.
- Prior to connecting the primary medication line to patient, apply a MedLite ID device below the drip chamber, at the primary medication injection site, and near the attachment of the venous access catheter (see figure) by running the infusion tubing through the tubing grooves on the device.
- Inspect tubing for twists or kinks, then close the clamshell door until it clicks.
- The MedLite ID device has two forms of identification for the medication line, the attached device itself and an activated light as well.
- To activate, press one of the attached devices on the circular squeeze point. This will activate the lights for all three devices within a given set. The devices will turn off after about 45 seconds.
- Pressing on any of the devices will turn all devices back on.
- The devices are for one infusion set use and should be disposed of when tubing is changed or treatment completed.
Warning and Disclaimer
This device should be installed by a medical professional. Do not use any
component of the device if the product packaging is damaged or opened. MedLite
ID is not responsible for use of the product taken from deteriorated packaging
or used on non-medication intravenous lines. MedLite, ID is a single use
device with multiple components. Never reuse any portion of the device, even
if the device appears undamaged. All portions of the device should be
discarded when tubing is changed, or the treatment completed. Care must be
taken after opening the device to protect from damage to the components. Prior
to installation, all portions of the device must be verified to be in good
working order.
If any portion of these instructions are disregarded, the medical professional
and their respective employers, agents, members, managers, partners, officers,
affiliates, parent entities, assigns, and all other persons or entities who may
be responsible for the disregard assume the risk of the use of the product.
Changes or modification to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
By using this product, it is presumed that this warning and disclaimer has
been read and understood. For further information or to share comments or
complaints about this product, please visit
www.medliteid.com
RF Exposure Information
This equipment complies with FCC/ISED radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC/ISED radio frequency exposure limits, human proximity to the antenna shall not be less than 20 cm during normal operation.
This device complies with Part 15 of the FCC Rules and this device also
contains
license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science
and Economic Development Canada’s license-exempt RSS(s). Operation is subject
to the following two conditions: (1)this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Contact: US www.medliteid.com EU www.medliteid.com
FCC ID: 2ATMC-IDAO1US IC: 26774-IDA01US HVIN: IDA01US
Patents: medliteid.com/patents
IFU: 02.25.2021 – v7.9