TECHNICAL CHARACTERISTICS

  • Model No.: EMPV-30RH05 EMPV-30RH06
  • Total power: 204W
  • Motor power: 200W
  • Led Light: 2x2W
  • Voltage: 120V
  • Frequency: 60Hz
  • Filter: Steel Baffle filter
  • Control: Touch ControlEmpava EMP-30RH06 30 in. 400 CFM Wall Mount Range Hood 1

Please note that this product is marked with a symbol: According to Waste of Electrical Electron Equipment
(WEEE) the directive, WEEE should be separately collected and treated. If at any time in the future you need to dispose of this product, please do NOT dispose of this product with household waste. Please send this product to WEEE collecting points where available.

Dear consumer
Thanks for your purchase of our range hood and we hope we can fully satisfy all of your needs. Please read the entire instructions carefully before proceeding to obtain the best results of operating the range hood.

MAIN PARTS NAME

EMPV-30RH05

****

EMPV-30RH06

INSTALLATION REQUIREMENT

  1. Do not install the range hood where there are many doors ro windows in order to avoid effecting the exhaust efficiency of the hood that is caused by air convection. (fig.1)
  2. Install the range hood right above the cooking surface. The recommended distance between the cooking surface and the lower edge of the range hood is a minimum of 27.56″ to a maximum of 31.5″. (Fig.2)
  3. In order to get the best performance, do not extend the vent pipe too long, and try to make the bend of the vent pipeless and straight, make sure the vent pipe connection is firm and airproof. (Fig.3)
  4. After hanging the range hood on the wall, make sure the hood is level and vertical. (Fig.4)
  5. The air Outlet is not allowed to connect to chimney flues or combustion gas ducts. The air outlet should under no circumstances be connected to ventilation ducts for a room in which fuel-burning appliances are installed.Empava EMP-30RH06 30 in. 400 CFM Wall Mount Range Hood 4

INSTALLATION PROCEDURES

SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.

  1. Step 1
    Put the vent pipe to the air outlet like this picture. And use one ST3.9×10 screw to fix the vent pipe.

  2. Step 2
    Match the hook to the holes of the inner duct cover and fix it well with M4 screws.

  3. Step 3
    Insert the inner duct cover into the outer duct cover.

  4. Step 4
    Matching the holes of the outer duct cover and blower box, fix the outer duct cover to the blower box using 8pcs M4*10 screw provided with the fixing tool as the direction of the illustrated.

  5. Step5
    According to the size of hook keyholes. Drill 3 holes in level in the wall with 10mm in diameter and 75~85mm in depth. Press the 3 expanding tube provided into the holes. Fix the hook using the 5×50 metal screw provided.
    Then insert three M5X50 screws to A and B And C holes to fix the hook on the wall steadily.Empava EMP-30RH06 30 in. 400 CFM Wall Mount Range Hood
9

  6. Step 6:
    Hang the entire hood onto the hook, ensure the hood is level and vertical.Empava EMP-30RH06 30 in. 400 CFM Wall Mount Range Hood
10

  7. Step 7

  8.  Draw the inner duct cover up to the suitable height, mark on the wall two keyholes of the outer duct cover bracket with pen.

  9. Put down the inner duct cover gently, drill the keyholes in 75-85 mm depth on the horizontal level using 10mm drill.

  10.  Press the expanding tube provided into the holes.

  11. Matching the inner duct cover with the holes, tighten the inner duct cover with two 5×50 metal screws provided.Empava EMP-30RH06 30 in. 400 CFM Wall Mount Range Hood 11

  12. Step 8
    Extend the air outlet of the exhaust pipe out-of-door. Try to make the bend of the exhaust pipe is no more than 120°.Empava EMP-30RH06 30 in. 400 CFM Wall
Mount Range Hood 12

OPERATING INSTRUCTION

Electronic Switch

Touch Control

  1. Light
  2.  Time
  3.  Speed down
  4.  Speed up
  5. Max speed
  6.  On /off Empava EMP-30RH06 30 in. 400 CFM Wall Mount Range Hood 13
  • A: Light
    Press the button once to turn on the light, press again to turn it off.

  • B. Timer
    In standby mode, press 3 seconds, to enter into time setting mode, Press “+” set hour (0-23 circle set) and press “–” set minute(0-59), No operation within 5 seconds for automatic confirmation. When working, press once to enter into delay turn-off mode for 3 minutes. Press again to increase delay turn-off time from 3-59 minutes. No operation for 5 seconds, the hood will be turned off in 3 minutes. Press again to turn off immediately.

  • C.- In standby mode, press to change to speed 1.

  • D.+ In standby mode, press to change to speeds 2 & 3.

  • E. Speeds
    In standby mode, press once to start high speed.

  • F. Power on/off
    In standby mode, press once to turn on all buttons. Press again to turn off the power. When working, press once to start delay turn off 3 minutes. In delay turn-off mode, press again to stop delay turn-off

MAINTENANCE

CAUTION: NEVER PUT YOUR HAND INTO THE AREA HOUSING WHILE THE FAN IS OPERATING. FOR THE OPTIMAL LEVEL FO OPERATION, CLEAN THE RANGE HOOD SURFACE, AN AND ALUMINUM FILTER REGULARLY.

  1. Use only mild soap or detergent solutions to clean the range hood surface. Dry surfaces using a soft cloth.
  2. Using a stainless steel cleaner to bring the glow back into a stainless finish.
  3. Clean the filter once a week or according to use status. Press the buckle of the filter slightly, take off the filter and put it into warm soapy water using mild detergent, wipe the filter with soft brush. Replace the filter after it’s dry.
  4. Clean the motor fan and other inside parts once a half-year or according to use status by QUALIFIED PERSON.
  5. DO NOT clean the motor with water or other liquid.

TO REPLACE LIGHT

To replace Led light (Pic.1) Сaution: LED light can not replace a new bulb, just replace a new LED light assembly. Make sure all the control switches are off, and the range hood is unplugged! Please follow the below instructions:

  1.  Take out the filters, and cut off the wire connection of the light.
  2.  Press the spring according to the arrow direction, then you can take off the LED light.
  3.  You can replace a new LED assembly with no more than a rating.
  4.  Then put the light assembly to the hood in the reverse direction. Connect the wire of the lamp.
  5.  Fit on the filters.Empava EMP-30RH06 30 in. 400 CFM Wall Mount Range Hood 15

WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:Empava EMP-30RH06
30 in. 400 CFM Wall Mount Range Hood 16
Empava EMP-30RH06 30 in. 400 CFM Wall Mount Range Hood
17

  • Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
  • Always turn hood ON when cooking at high heat or when flambeing food (i.e.Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
  • Clean ventilating fans frequently. Grease should not be allowed to accumulate on fans or filter.
  • Use proper pan size. Always use cookware appropriate for the size of the surface element.
  •  NEVER PICK UP A FLAMING PAN – You may be burned.
  • DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
  •  Use an extinguisher ONLY if:
  •  You know you have a Class ABC extinguisher, and you already know how to operate it.
  •  The fire is small and contained in the area where it started.
  •  The fire department is being called.
  • You can fight the fire with your back to an exit.

WARNING: TO PROVIDE PROTECTION AGAINST ELECTRIC SHOCK, CONNECT TO PROPERLY GROUNDED OUTLETS ONLY.
GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance

TROUBLESHOOTING

EMPAVA APPLIANCE INC. Add: 15253 Don Julian Rd, City of Industry, CA 91745 Tel: 888-682-8882 www.empava.com