FireAngel SCB10 Combination Smoke and Carbon Monoxide Alarm User Manual

June 6, 2024
FireAngel

SCB10 COMBINATION SMOKE AND
CARBON MONOXIDE ALARM
USER MANUAL GN5380R4EN
18 LHK0191 EN50291-1:2018 EN14604:2005+AC:2008

The original English version of the manual, from which these translations were taken, has been independently approved. In case of discrepancy with translated parts, FireAngel Safety Technology Limited confirms that the English guide is true and correct.
This optical smoke alarm is suitable for detecting slow smoldering fires. Like other smoke alarm devices, it can be subject to nuisance alarms from steam and should not be placed near bathrooms. For the earliest warning, we recommend this combination smoke and CO alarm is fitted in all rooms where the temperature is between 0°C (32°F) and 40°C (104°F). Prolonged exposure to temperatures outside those stated above will reduce product life.
Check with local building and fire regulations for your property, to ensure compliance. This alarm must be installed by a competent person, able to install according to the instructions. This combination smoke and CO alarm is not intended for any non-residential, commercial or industrial application.

POSITIONING

Your combination smoke and CO alarm are suitable for the landing, hallway, bedroom, living room, and dining room.
Aim to install the alarm in a bedroom or hallway located close to the sleeping area.
If more than one sleeping area exists, locate additional alarms in each sleeping area. If the alarm is located in the same room as a fuel-burning appliance, it should ideally be located 3m from the potential CO source.
Common sources of CO include oil and gas boilers, portable generators, oil or solid fuel cookers, gas or paraffin heaters, barbecues, clogged chimneys, wood or gas fireplaces, any gas or fossil-fuel-burning appliance.
The alarm should be sited at least 300mm from light fittings and walls. Ideally as central as possible in the room.
It should be positioned at no more than 600mm vertically below the highest point in the room.
If positioning your smoke alarm on the wall, the top of the alarm must be between 150mm and 300mm below the ceiling, and at least 300mm from a neighboring wall.

INSTALLATION

WARNING!  To prevent injury, this device must be securely attached to the ceiling/wall in accordance with the installation instructions

Fit the baseplate to the ceiling or wall using the screws provided.| Push and twist the alarm clockwise onto the baseplate to activate the alarm.| Press the Test /4x button. The alarm will sound at a reduced alarm volume.
---|---|---

THE ALARM MUST BE INSTALLED ON THE BASEPLATE TO ACTIVATE THE ALARM.
After activation, three-color LEDs (green/amber/red) will light up briefly and the device will beep. The green LED will then flash constantly for 40 seconds. Following this, the green LED on the front of the alarm should flash once every 40 seconds (approx.) to show that it is active. The alarm test sound pattern will be: 3 long beeps followed by a 1.5-second pause, then 4 short beeps followed by a 5-second pause. This cycle will repeat for the duration of the test. The red LED will flash the same pattern. This CO alarm should not be seen as a substitute for the proper installation, use & maintenance of fuel-burning appliances (including appropriate ventilation & exhaust systems), nor the sweeping of chimneys.

MAINTENANCE

Do not use any other test method except the process described in this manual.
Do not tamper with the alarm, for the risk of electric shock or malfunction.

Test the alarm every month.| Vacuum your alarm every 3 months.| To prevent the possibility of contaminating the sensor in your alarm does not paint the alarm, do not use cleaners,  aerosol sprays, or solvents.| Replace the alarm every 10 years
---|---|---|---

Your alarm must be replaced immediately if the device indicates End of Life: 3 chirps and 3 ambers LED flashes every 40 seconds. An alarm signaling End of Life may not detect a fire or CO leak.

TECHNICAL SPECIFICATION

Model: SCB10
Product standards: EN 14604:2005+AC:2008 & EN 50291-1:2018
Type of apparatus: Type B
Power Supply: 3V (EVE CR17450) (non-replaceable, sealed-in battery) (up to 10 years lifetime)
The sensor of Smoke: Optical
Smoke alarm silence: 10 minutes
The sensor of CO: Electrochemical
CO alarm sensitivity Setting: Certified to
EN50291-1:2018
30PPM Without alarm before 120 minutes
50PPM Between 60 to 90 minutes
100PPM Between 10 to 40 minutes
300PPM Less than 3 minutes
Standby Current: <20μA (average)
Alarm Current: <20mA (average)
Operation Ambient Condition: 0~+40°C, 30~93%RH non-condensing
Storage/Transport Ambient Condition: -20~+50°C, 10~95% RH non-condensing
Alarm sound : ≥85dB at 3m @3.0 ± 0.5 kHz
Low Battery warning silence: 9 hours
Installation Location: Ceiling and wall
Detection range: Max. 40 m2 within a room.
Size: Φ 134*40mm
Weight: 200g (net)

This combination of smoke and CO alarm are designed to protect from the danger of fire. It is also designed to detect carbon monoxide gas from any source of combustion. (It is  not designed to detect any other gas.) The SCB10 combination Smoke/Carbon Monoxide Alarm has two separate alarms.
The CO Alarm is not designed to detect fire or any other gas. It will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas. The Smoke Alarm will only indicate the presence of smoke that reaches the sensor. The Smoke Alarm is not designed to sense gas, heat or flames.

Note: This user manual is also available in large text and other formats. Please email: internationalsupport@fireangeltech.com or call +44 (0) 330 094 5830 for further information.

SMOKE ALARM AWARENESS

Never ignore any alarm. If there is any question as to the cause of the alarm, always assume that it is an actual fire.
The smoke alarm takes precedence if both smoke and carbon monoxide are present.

The smoke alarm signal pattern is a repeated cycle of 3 long beeps followed by 1.5 seconds of silence. The red LED will flash the same pattern.
Red LED:
Alarm sound:
The alarm will sound at a lower volume for around 10 seconds, then increase to the normal alarm volume of 85dB.

GET OUT IMMEDIATELY. Stay close to the floor, cover your mouth with a cloth and conserve breath as you crawl to safety.

Touch doors to feel if they are hot before opening them, fire may have walled up behind them. If necessary, use an alternative exit.

STAY OUT of the building. Never go back inside a burning building for any reason.

GET THE FIRE BRIGADE OUT. Call the emergency number from outside the building.

When fire strikes, a prepared and practiced escape plan could prove vital. Consider and discuss the following hints:

  • Ensure everyone is familiarised with the alarm signal.
  • Keep all windows and doors closed except for escape purposes.
  • Plan a set meeting place for after an escape.
  • Prepare and practice an escape plan before a fire starts.
  • Draw a floor plan. Have fire drills often. Practice your escape.

CO ALARM AWARENESS

A loud alarm is a warning that potentially lethal levels of carbon monoxide are present.
Never ignore this alarm, further exposure can be fatal.
Immediately check residents for symptoms of CO poisoning. Contact the proper authorities to resolve all CO problems.

The CO alarm signal pattern is a repeated cycle of 4 long beeps followed by 5 seconds of silence. The red LED will flash the same pattern.
Red LED:
Alarm sound:
The alarm will sound at a lower volume for around 10 seconds, then increase to the normal alarm volume of 85dB.

Keep calm; open doors & windows to ventilate the property. Stop using all fuel-burning appliances and if possible, turn them off.

Evacuate the property, leaving doors & windows open.

Ring your fuel supplier on their emergency number.
Do not use appliances again until they have been checked by an expert.

Get medical help immediately for anyone suffering the effects of CO poisoning (headache, nausea), and advise that carbon monoxide poisoning is suspected.

Depending on the level of CO detected, it can take up to 10 minutes to clear the sensor and the alarm to stop.
Do not re-enter the property until the alarm has stopped.

The following symptoms may be related to CO poisoning which all household members should be aware of:

  • Mild Exposure: Slight headache, vomiting, fatigue (often described as ‘flu-like’ symptoms).
  • Medium Exposure: Severe throbbing headache, drowsiness, confusion, fast heart rate.
  • Extreme Exposure: Unconsciousness, convulsions, cardiorespiratory failure, death.

Your CO alarm monitors levels of CO as parts per million (ppm) in the air surrounding the detector.
35ppm The maximum allowable concentration for continuous exposure for healthy adults in any 8 hour period (as recommended by the Occupational Safety & Health Administration).
200ppm Slight headache, fatigue, dizziness, nausea after 2 – 3 hours.
400ppm Frontal headaches within 1 – 2 hours, life-threatening after 3 hours.
800ppm Dizziness, nausea & convulsions within 45 minutes. Unconsciousness within 2 hours. Death within 2 – 3 hours.
This apparatus is designed to protect individuals from the acute effects of carbon monoxide exposure. It may not, however, prevent the chronic effects of carbon
monoxide exposure and will not fully safeguard individuals at special risk (age, pregnancy) or with specific medical conditions. If in doubt, consult your doctor.

TROUBLESHOOTING/TECHNICAL SUPPORT

If your alarm device does not sound during testing:| • Check that your alarm is activated (see Figure 2b).
• If testing after first activating, allow 40 seconds for the alarm to settle.
• Press and hold the center of the Test/button firmly.
• If the alarm has been silenced and is in low sensitivity mode it may not test. Wait for 15 minutes then try again.
---|---
If your alarm device continues to sound a known false alarm:| • Check the location of your alarm device.
• Clean the alarm device.
If your alarm device ‘chirps’ intermittently:| • Check the location of your alarm device.
• Check that your alarm device is definitely the source of the chirping; make sure the noise isn’t coming from another alarm.

FireAngel Safety Technology Limited. Email: (UK) technicalsupport@fireangeltech.com, (DE) technik@fireangeltech.com,
(FR) supporttechnique@fireangeltech.com, (NL) klantenservice@fireangeltech.com, (INT) Internationalsupport@fireangeltech.com

SILENCE FEATURE – SMOKE ALARM ONLY

In a known false alarm, the alarm can be silenced temporarily.

Press the Test/button.| The alarm will silent for 10 minutes and the red LED will continue to flash.
---|---

Combination smoke and CO alarms can react to cooking fumes or other non- emergency situations. Your alarm features Silence technology. In the event of a known false alarm you can temporarily silence it by pressing the Test/button. Your alarm will automatically return to full sensitivity after 10 minutes.
NEVER IGNORE ANY ALARM. If an alarm is sounding, it is warning you of a potentially hazardous situation. Do not ignore it. Ignoring the alarm may result in injury or death. If your alarm sounds and you are not absolutely certain of the source, get everyone out of the house immediately.

SLEEP EASY™ FEATURE

If a low battery double ‘chirp’ occurs at night, the alarm can be silenced so it does not keep you from sleeping.

Press the Test/button.| The alarm will be silent for 9 hours and the amber LED will continue to flash.| Replace the alarm the following day.
---|---|---

Your alarm will still detect smoke and CO during the Sleep Easy mode but you must replace the alarm within 30 days.
Replace your smoke alarm device immediately to ensure protection in case of fire. If the alarm is less than 10 years old, contact Technical Support.
YOUR ALARM CAN NOT BE SILENCED IF THE CHIRP IS INDICATING A FAULT.

LOW BATTERY WARNING

When the alarm battery is low, the alarm will ‘chirp’ once and the amber LED will flash every 40 seconds.| Replace the alarm immediately.
---|---

THE COMBINED SMOKE AND CO ALARM MUST BE REPLACED IMMEDIATELY IF THERE IS A FAULT. IF THE ALARM HAS A FAULT IT CANNOT DETECT A FIRE OR CO LEAK.

FAULT INDICATION

If there is a fault, the alarm will ‘chirp’ twice and the amber LED will flash twice every 40 seconds.| If within warranty, contact Technical Support.
---|---

WARRANTY AND DISPOSAL

FireAngel Safety Technology Limited warrants to the original purchaser that its enclosed smoke alarm device is free from defects in materials and workmanship under normal residential use and service for a period of 3 (three) years from the date of purchase. Provided product is sent back to FireAngel Safety Technology Limited with proof and date of purchase, FireAngel Safety Technology Limited hereby warrants that during the 3 (three) year period commencing from the date of purchase FireAngel Safety Technology  Limited, at its discretion, agrees to replace the unit free of charge. The warranty on any replacement SCB10 alarm will last for the remainder of the period of the original warranty in respect of the alarm originally purchased – that is from the date of original purchase and not from the date of receipt of the replacement product. FireAngel Safety  Technology Limited reserves the right to offer an alternative product similar to that being replaced if the original model is no longer available or in stock. This warranty applies to the original retail purchaser from the date of original retail purchase and is not transferable. Proof of purchase is required.

This warranty does not cover damage resulting from accident, misuse, disassembly, abuse or lack of reasonable care of the product, or applications not in accordance with the user manual. It does not cover events and conditions outside of FireAngel Safety Technology Limited’s control, such as Acts of God (fire, severe weather etc.). It does not apply to retail stores, service centers or any distributors or agents. FireAngel Safety Technology Limited will not recognize any changes to this warranty by third parties.

FireAngel Safety Technology Limited shall not be liable for any incidental or consequential damages caused by the breach of any expressed or implied warranty.
Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration for 3 (three) years.

This warranty does not affect your statutory rights. Except for death or personal injury, FireAngel Safety Technology Limited shall not be liable for any loss of use, damage, cost or expense relating to this product or for any indirect, or consequential loss, damages or costs incurred by you or any other user of this product.

DISPOSAL

Waste electrical products and batteries should not be disposed of with your other household waste. The alarm and its batteries is ideally suited for disposal within the waste electronic and electrical equipment (WEEE) recycling scheme.
Please recycle where facilities exist. Check with your local authority, retailer or contact our Technical Support team for recycling/disposal advice as regional variations apply.
To deactivate the alarm, use a screwdriver to remove the plastic pin from under the label on the back of the alarm. Insert the pin into the deactivation hole. Once the alarm has been deactivated, the battery will be depleted and the alarm will stop emitting the low power warning chirp. The unit is now ready for disposal.
Deactivation is permanent, once the alarm has been deactivated, it will no longer function.
Do not attempt to open. Do not burn.

19
0905-CPR-00690
EN 14604: 2005 + AC:2008
Smoke alarm device
DOP: FSTDOP19005
© FireAngel Safety Technology Limited
Vanguard Centre,
Coventry CV4 7EZ,
The United Kingdom.
www.fireangeltech.com
Technical Support
Online: www.fireangeltech.com
E-mail: internationalsupport@fireangeltech.com
Phone: +44 (0) 330 094 5830

Documents / Resources

| FireAngel SCB10 Combination Smoke and Carbon Monoxide Alarm [pdf] User Manual
SCB10, Combination Smoke and Carbon Monoxide Alarm
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FireAngel User Manuals

Related Manuals