- OPERATING INSTRUCTIONS
- DESCRIPTIO N OF THE APPLIANCE
- PRE-OPERATING CHECKS AND OPERATIONS
- APPLIANCE START-UP
- INSTALLATION OF CORD WINDER HOOKS
- HOW TO USE THE APPLIANCE
- OPERATING MODES
- HOW TO ELIMINATE CONDENSATE
- REMOTE CONTROL OPERATION
- SAFETY FUNCTIONS
- CARE AND MAINTENANCE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
argo ALTEA Portable Air Conditioner
OPERATING INSTRUCTIONS
Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Store these instructions in a safe place for future reference.
- Appliance is filled with flammable gas R290.
- Before installing and using the appliance, read the owner manual.
- Before installing the appliance, read the installation manual.
- Any repairs you need, contact the nearest authorized Service Centre and strictly follow manufacturer’s Service Manual.
The Refrigerant R290
- To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The refrigerant is the fluoride R290 = 3 GWP (Global warming potential). This refrigerant is flammable and inodorous. It can lead to explosions under certain conditions, however the flammability of this refrigerant is very low and it can be ignited only by fire.
- Compared to other common refrigerants, R290 is a non-polluting refrigerant with no harm to the ozonosphere and a no effect upon the greenhouse effect. R290 has very good thermodynamic features which lead to a really high energy efficiency. The units therefore need less filling.
Warning:
Do not try to accelerate the defrosting process or to clean the appliance in
different ways other than those recommended by the manufacturer. Should repair
be necessary, contact your nearest authorized Service Centre. Any repairs
carried out by unqualified personnel may be dangerous. The appliance has to be
stored in a room that doesn’t have any continuously operating ignition
sources. (for example: open flames, an operating gas appliance or an operating
electric heater.) Do not pierce or burn.
Appliance has to be installed, used and stored in a room with a floor area
larger than 14 m2. For repairs, strictly follow manufacturer’s instructions
only for appliances filled with R290
GENERAL OPERATING AND SAFETY INSTRUCTIONS
-
This appliance is a local air conditioner designed for domestic use.
-
Only use this air-conditioner as described in this manual.
-
Ensure that the required voltage and frequency (220-240V/50 Hz) match the available power source.
-
Fuse style T3.15AH250V, the electricity passing through the fuse cannot be above 3.15A.
-
This appliance can be used by children aged from 8 years and above and people with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
-
Children shall not play with the appliance.
-
Cleaning and user maintenance shall not be made by children without supervision.
-
Ensure that the electricity system is able to deliver the operating current required by the air conditioner, in addition to that normally absorbed by other appliances (household appliances, lighting system, etc.). Please refer to the maximum power input data indicated on the air conditioner’s data plate.
-
Connection to the electricity grid must take place in accordance with current installation standards.
-
Ensure that the automatic switches and system protection valves are able to withstand a start-up current of 6A (normally for less than 1 second).
-
The system socket must always be fitted with an efficient earth connection.
-
Make sure that the plug is fully inserted. Do not use multiple adapters. Do not touch the plug with wet hands. Make sure that the plug is clean.
-
Do not use the plug as a means by which to start/stop the air conditioner: use the ON/OFF button on the remote control or on the control panel.
-
Do not install the air conditioner in rooms where it may receive water splashes (e.g. laundry rooms).
-
This air conditioner can be used by children of 8 years of age or older, and by persons with reduced physical, sensory and mental abilities or who lack the necessary know-how and experience to operate it, if under the supervision or instruction of a person responsible for their safety, so that they are fully aware of the attendant risks.
-
Before moving or cleaning the device, ensure that it is unplugged from the socket.
-
Do not move the air conditioner while it is operating; first turn the appliance off, check for any condensate build-up and empty it if necessary.
-
To turn the appliance off, set the remote control to OFF and remove the plug from the socket. Pull on the plug only. Do not pull the cord.
-
Do not use the appliance if the cord or plug are damaged. If the power supply cord is damaged, it must be replaced by the manufacturer, dealer or a similarly qualified person so as to avoid any safety risks.
-
Keep the unit away from fire, possible fire sources, inflammable or explosive objects.
-
Do not leave the unit unattended while it’s operating, turn the unit off and unplug it.
-
If drainage hose is used, the ambient temperature musnt’t be lower than 0°C. It can cause water leakage to the air conditioner.
-
Do not splash or pour water on the air conditioner
PRECAUTION! -
Do not insert any objects into the air conditioner: this is very dangerous as the fan turns at high speed.
-
Ensure that air circulates freely around the unit. Do not cover the air intake and delivery grilles with drapes or any other means.
WARNING! -
The air conditioner must be positioned at least 50 cm from the wall or any other obstacles, on a flat and stable surface so as to avoid water leaks.
-
The air conditioner is fitted with a system for protecting the compressor from overload. This means that the compressor only starts 3 minutes after its previous stoppage.
-
Please wait at least 3 minutes before starting the unit. This helps prevent the compressor from being damaged.
WARNING! -
In the event of an anomaly, switch the appliance off and unplug it from the socket. Do not dismantle or attempt to repair or modify the product. In the event of a malfunction, contact the service centre directly.
WARNING! -
Do not expose the air conditioner to direct sunlight, as the colour of the materials may change; moreover, the appliance may overheat causing the protection mechanism to intervene and switch the appliance off.
-
Do not use insecticides, oils, detergents or spray paints near the appliance; do not use aggressive chemical detergents to clean the casing: this may damage the finish and colour.
-
Close all open windows to maximise air conditioning efficiency.
The manufacturer will not be held liable if safety and accident prevention rules are not observed.
DESCRIPTIO N OF THE APPLIANCE
- CONTROL PANEL AND FUNCTION BUTTONS WITHOUT REMOTE CONTROL
- HORIZONTAL FINS AND AIR INTAKE
- VERTICAL FINS AND AIR INTAKE
- WHEELS
- AIR FILTER
- AIR EXPULSION HOSE END FITTING
- AIR EXPULSION HOSE
- JOINT
- END FITTING FOR WINDOW
- WINDOW ACCESSORY
- CORD CABLE CLAMP
- REMOTE CONTROL
- Min/max operating limits (internal temperature)
- Cooling: 16 °C DB / 35 °C DB
- Dehumidification: 16 °C DB / 35 °C DB
- Cooling mode room temperature adjustment range: 16 °C DB / 30 °C DB
PRE-OPERATING CHECKS AND OPERATIONS
The following space must be maintained to ensure the operating efficiency of the portable air conditioner.
APPLIANCE START-UP
Open the packaging and remove the box from above. Remove the product and the other elements supplied (illustrated in the box below).
- LCD remote control
- Round fitting for window (1) to be positioned between the end of the tube and the end fitting for the window (in the packing it’s the same fitting installed on porthole kit (A)
- Flat fitting for positioning between the air discharge outlet and the hose
- Clamp
- Drain hose
- Window unit kit (3 pcs) A+B+C
- Type AAA batteries for the remote control
- End fitting for window, supplied into two parts to be joined with 2 flaps that fit together (2)
- Hose
- Cord winder
- Screws
- Round fitting for window unit, to be positioned between the end of the tube and the window unit (A)
- Window unit (B)
- Cap (C )
Position the product vertically on a flat and stable surface, as close as possible to a window and at least 50 cm from walls or other nearby obstacles.
INSTALLATION OF CORD WINDER HOOKS
- Hook
- Screw
Install the cord winder hooks to the back of the unit using the screws, as
shown in the figure.
The hooks must be positioned facing upwards and downwards.
USE WITH END FITTING FOR WINDOW
Connect the flat fitting to the hose, extend the hose as far as necessary for
reaching the outside and it connect to the back of the air conditioner. Connect
the round window fitting (1) to the end of the hose then the end fitting for
the window (2), previously obtained by joining parts A and B When
the appliance is not being used, wind the power cord around the hooks.Wind the
cord around the hook.
Next, slide the flat fitting downwards into the grooves (A) and secure it
with the hook (B).
The upward-facing side of the flat fitting is marked “TOP”. Open the windows
and lock one of the two leaves with the handle.
Place the end fitting against the fixed leaf of the window, and draw the other
leaf towards it.
USE WITH WINDOW UNIT KIT
-
To make the hole in the glass it is advisable to take the porthole kit accessory to the glazier
-
Insert the window unit into the window.
-
Insert the round fitting onto the flexible pipe.
-
Insert the round fitting into the retractable flexible pipe and insert the latter with its round fitting into the window unit without the plug..
-
Insert the flat fitting onto the hose.
-
Slide the flat fitting downwards into the grooves (A) and secure it with the hook (B).
The upward-facing side of the flat fitting is marked “TOP”. -
The outlet must be between 40 cm and 130 cm above the ground. Avoid tight curves or bends in the flexible hose.
-
If the air conditioner is not used for prolonged periods, disconnect the pipe and plug the window unit. Connect the power cord to a suitable electric socket (220–240 V). Insert the supplied batteries into the remote control and make sure the poles match. Select the desired operating mode from the remote control.
HOW TO USE THE APPLIANCE
This appliance can be used for cooling, dehumidifying and ventilating.
When switching between modes, the fan continues to rotate but the compressor
stops: the compressor will start after 3 minutes. This delay protects the
compressor from potential damage. THE DISCHARGE TUBE MUST ALWAYS BE CONNECTED to the
appliance: the only exception is when the appliance is used solely for
dehumidification, in which case it is advisable to let the appliance discharge
directly into the environment for maximum efficiency (consult the
“Dehumidification Mode” paragraph). Regularly clean the air filters beneath
the easily removable rear grille to keep the air conditioner working
efficiently.
OPERATING MODES
-
COOLING MODE (COOL)
- Press the MODE button to select Cool mode
- The “Cool” LED on the control panel will turn on.
- The temperature can be adjusted to between 16 °C and 30 °C.
- In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the temperature setting and, when switched back on again, retains this setting.
- In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
- For more silent operation, run the fan at low speed.
-
DEHUMIDIFICATION MODE (DRY)
- Press the MODE button to select Dry.
- The temperature is controlled by the PCB and cannot be regulated.
- In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the settings and, when switched back on again, retains them.
- The fan speed is set to low and cannot be adjusted.
NOTE
The air conditioner does not cool the room when it is used as a dehumidifier.
When the appliance is used as a dehumidifier, the flexible hose must not be connected.
For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into the environment.
The dehumidification mode is recommended during autumn and winter.
If used in summer, it is best to leave the flexible hose attached so that the hot air can be discharged towards the outside rather than into the room.
During dehumidification, continuous drainage should be implemented (consult the next chapter, “CONDENSATE ELIMINATION”).
-
VENTILATION MODE (FAN ONLY)
- Press the MODE button to select Fan and wait until the relative icon appears.
- In this mode, the fan speed can be adjusted.
- The temperature cannot be adjusted.
HOW TO ELIMINATE CONDENSATE
This appliance automatically vaporises condensate in the cooling mode.
When the air conditioner operates in cooling mode, there is no need to drain
condensate continuously; only in certain weather conditions with very humid
air may it occur that water deposits inside the unit. When its inner tank is
full, the air conditioner beeps 8 times and the message “H8” appears on the
display to signal that the tank is full and stop the appliance’s operation.
INSTALLATION OF THE DRAINAGE HOSE
- Remove the rubber plug at the back of the unit
- Mount the clamp (2) onto the back of the unit, to the right of the drainage opening (1), using a screw (3).
- Screw the drainage hose (4) onto the drainage opening then secure it with the clip (2).
- Insert the cap onto the other end of the drainage hose (1), secure it with the clip (2) then insert it into the clamp (5).
Cooling
When the unit operates in the cooling mode, ensure that the rubber cap closing
the drainage opening on the back of the appliance is properly positioned.
To empty the container, switch the air conditioner off and unplug the cord.
Remove the cap from the rear drainage opening and place its end over a normal
drain. Ensure that the tube is not twisted or bent. The tube must slope
downwards. Re-close the drainage opening with the cap, insert it into the
clamp and resume use of the air conditioner.
Dehumidification
WARNING!
When using the air conditioner in dehumidification mode, we recommend always
ensuring continuous drainage, in order to maximise dehumidification
efficiency.
Use the drainage outlet on the appliance. The water can be drained into a
drain by simply connecting a tube with 14 mm internal diameter (not supplied).
- Remove the cap by turning it anti-clockwise then remove the plug.
- Screw the connection tube provided turning it clockwise.
- Next, insert the drainage tube into the connection tube.
- Avoid bends in the drainage tube.
REMOTE CONTROL OPERATION
- Swipe to open the cover in the direction indicated by the arrow.
- Insert the batteries (AAA, LR03, 1,5V – not supplied) into the remote control, respecting the polarity indicated.
- Put the cover back on.
- Point the remote control at the receiver on the air conditioner.
- The remote control should be placed within 6 meters of the receiver.
- There must be no obstacles between the remote control and the receiver.
- Do not drop or throw the remote control.
- Do not place the remote control under strong sunlight or under heating devices and other heat sources.
- Remove the battery from the remote control when it is not used for a long time.
- If there is no sound and the transmission symbol on the display screen does not flash, the battery needs to be replaced.
- If the reset occurs when the remote control button is pressed, the electrical quantity is lacking and the battery must be replaced.
- Battery waste must be disposed of properly.
Note:
- The image is a general remote control, it contains almost all the function keys. They may be slightly different for the material (depends on the model).
INFORMATION FOR CORRECT DISPOSAL OF THE BATTERIES PURSUANT TO EUROPEAN
DIRECTIVE
2006/66/EC and amendments Directive 56/2013/EC
Replace the batteries when depleted. At the end of their working life,
batteries must be disposed of separately from unsorted waste. They must be
must be delivered to appropriate separated waste disposal plants or to dealers
that provide a similar service. Separate waste disposal of batteries prevents
potential negative effects on the environment and human health resulting from
inadequate disposal, and also allows the materials from which it is made to be
recovered and recycled in order to achieve significant savings in terms of
energy and resources. The separate disposal obligation is underlined by the
crossed-out dustbin symbol appearing on the battery. Illegal disposal of the
product by the user is subject to administrative penalties as per current
regulations.
FOR OPTIMUM OPERATION OF THE REMOTE CONTROL, ADDRESS THE TRANSMITTER HEAD
TOWARDS THE RECEIVER LOCATED ON THE AIR CONDITIONER.
To operate the remote control, press the ON / OFF button on the handset. The
icon on the remote control display will flash once and you will hear a sound
signal indicating that the signal has been sent to the air conditioner.
In off mode, the set temperature and set timer will be displayed on the remote
control.
BUTTONS ON REMOTE CONTROL
- ON / OFF BUTTON
- MODE BUTTON
- TEMPERATURE AND TIMER ADJUSTMENT BUTTONS
- FAN BUTTON – VENTILATION SPEED
- X-FAN BUTTON (only on remote control)
- SLEEP BUTTON
- TIMER BUTTON
REMOTE CONTROL DISPLAY
- A. Cooling
- B. Dehumidification
- C. Ventilation
- D. Temperature setting
- E. Timer setting
- F. Speed setting
- G. Lock
- H. Sleep mode setting
- I. X-FAN function
- L. Signal transmission
- N. T-OFF off timer
- M. T-ON on timer
ON/OFF BUTTON
Press this button to switch the unit on or off.
MODE SELECTION BUTTON (MODE) (on remote control and on the unit)
Press this button to select the various operating modes, according to the
following sequence: In the COOL mode the display lights up. In the DRY and FAN
modes the display does not light up.
The LEDs on the control panel will light up according to the selected mode
FAN SPEED ADJUSTMENT BUTTON (on remote control and on the unit)
Press this button when the appliance is on to adjust the fan speed, on the
control panel press the FAN button, the LED indicators will light up
corresponding to the selected speed automatic (AUTO), low (Low), medium (Med)
or high (High). On the remote control, however, the ventilation speed
selection sequence will be as follows:
The fan speed cannot be adjusted in DRY mode and is fixed to low speed.
+ – ADJUSTMENT BUTTONS (on remote control and on the unit)
These buttons can be used to adjust the temperature and set the timer.
The temperature can be adjusted to between 16 °C and 30 °C.
Increase temperature(+):
- Allows for adjusting the desired temperature in cooling (COOL) mode.
- Whenever the(+) button is pressed, the set temperature increases by 1 °C.
Decrease temperature (- ):
- Allows for adjusting the desired temperature in cooling (COOL) mode.
- Whenever the ( – ) button is pressed, the set temperature decreases by 1 °C.
The same button allows you to set the TIMER.
By holding down the + or – button for 2 seconds on the remote control, you can
quickly set the temperature.
SLEEP BUTTON
Press this button to activate the Sleep function, which automatically adapts
the temperature to changes in body and room temperature throughout the night,
so as to optimise comfort when sleeping and minimise consumption.
In cooling mode, the temperature increases by 1 °C in an hour then by 2 °C in
two hours, and remains in this setting for the whole period. The Sleep
function is not available in the ventilation, dehumidification and auto modes.
The indicator light turns on display of remote control whenever the Sleep
function is set.
TIMER BUTTON (on both the remote control and portable unit)
Press and hold this button for 1 second to set the timer.
-
Timer-on (automatic switch-on)
When the appliance is off, this button is used to set a delay after which the unit will switch on.
Remote control: Press TIMER. The T-ON and H icons will light up on the remote control. Press the + and – buttons within 5 seconds to set the delay. The T-ON icon will remain on to indicate that the TIMER has been set.
Portable unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm.’ -
Timer-off (automatic switch-off)
When the appliance is running in the COOL mode, set a delay after which the unit will switch off.
Remote control: Press TIMER. The T-OFF and H icons will light up. Press the + and – buttons within 5 seconds to set the delay. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm. The T-OFF icon will remain lit to indicate that the switch-off TIMER is running.
Portable unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm.
Resetting the timer: If a TIMER has been set, press TIMER to display the
delay. Press TIMER again to cancel the setting.
By holding down the + or – button for 2 seconds on the remote control, you can
quickly set the temperature.
X-FAN BUTTON (only on remote control)
In cooling and dehumidification mode it is possible to activate the X-FAN
function.
After pressing the X-FAN button on the remote control, with the unit off, the
unit’s internal fan continues to operate for a short time at minimum speed, to
allow any residual water in the air pipe to dry. If you want to stop this
function, press the X-FAN button on the remote control again
TEMPERATURE AND ERROR DISPLAY
Problem | Cause | Solution |
---|---|---|
H8 | Tank full of water. | Empty the tank. |
If the problem persists, contact a service centre.
F1| Room temperature sensor failure.| Contact a service centre.
F2| Failure of temperature sensor on the evaporator.| Contact a service
centre.
F0| Refrigerant leakage. Air conditioner out of order.| Contact a service
centre.
H3| Overload protection device on compressor.| The room temperature exceeds
the appliance’s operating range (beyond 35°) or there is too much humidity.
Wait for the temperature to drop below 35 °C.
Check if the evaporator and compressor are obstructed by objects. If they are, remove the objects, disconnect the unit then restore the power supply.
Clear the obstructed ventilation grilles.
If the problem persists, contact a service centre.
E8| Overload protection.
F4| The external temperature sensor has short-circuited.| Contact the service
centre.
The temperature and error display lights up only in the COOL mode. In the DRY and FAN modes the display does not light up.
SAFETY FUNCTIONS
REMOTE CONTROL LOCK
Simultaneously press “+” and “-” to lock the remote control.
The “Lock” icon will light up on the remote control, and the latter will not
respond to commands.
SWITCHING BETWEEN °C AND °F.
Press the “-” and “MODE” buttons simultaneously to switch between °C and °F.
LIGHT FUNCTION
Press the “+” and “FAN” buttons simultaneously for 3 seconds to set the
activation/ deactivation of the lamp.
CARE AND MAINTENANCE
WARNING!
Prior to carrying out any cleaning or maintenance, unplug the unit from the
power socket.
-
Cleaning the air filters
The air filter must be checked at least once every two weeks of operation. Operating with dirty or clogged filters will decrease the effectiveness of the air conditioner and can cause serious problems.
To remove the filter, release the rear grille (1) then slide out the filter by gently pulling it sideways (2). Use a vacuum cleaner to remove any dust. Should this not be sufficient, wash the filter with lukewarm water and neutral detergent (if necessary), rinse it with cold water then leave it to dry naturally before putting it back in place. After putting the filter back in place, close the grille and resume use of the air conditioner. -
2. Cleaning the casing.
Use a soft damp cloth to clean the outer surface of the air conditioner.
Do not use excessively hot water, solvents, petrol or other aggressive chemical compounds, talcum powder and brushes: they may damage the surface or colour of the casing.
Remove any stains using warm water with a little neutral detergent.
Do not pour water onto the air conditioner to clean it: this may damage the internal components or cause a short circuit. -
Storage.
When you do not envisage using the air conditioner for a long time, clean the filters before storing it away.
Keep the appliance in a vertical position at all times. Do not place any heavy objects on the
top and, if possible, protect the air conditioner with a plastic sheet. -
Transport.
Preferably keep the air conditioner in the vertical position when transporting it.
Should this not be possible, rest it on its right-hand side; when it reaches its destination, immediately put the= appliance in the vertical position and wait at least 4 hours before using it in the cooling mode. -
For complete safety, regularly check the condition of the power cord; should it be damaged through use, contact the Service Centre to replace it.
TIPS FOR MAXIMISING COMFORT AND MINIMISING CONSUMPTION
CHECK that:
- the unit’s extraction and delivery grilles are always unobstructed;
- the air filters are always clean: a dirty filter will decrease the passage of air and thus reduce the unit performance;
- the doors and windows are closed, to avoid infiltration of unconditioned air;
- the flexible hose is correctly positioned, without folds or sharp bends;
- the room temperature is above 18 ºC for the cooling mode, and above 10 ºC for dehumidification mode.
REGULATION (EU) No. 517/2014 – F-GAS
The unit contains R290, a natural greenhouse gas with global warming potential
(GWP) = 3 – Kg. 0,16 = 0,00048 Tons CO2 equiv.
Do not release R290 into the atmosphere.
INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH
EUROPEAN DIRECTIVE 2012/19/EU
This appliance may not be scrapped with domestic waste at the end of its life
cycle. We call your attention to the crucial role played by the consumer in
the re-use, recycling and other forms of recovery of such waste.
The appliance must be scrapped by a sorted waste disposal centre or by
returning it to the retailer (no charge is levied for this service), when you
purchase a new equivalent appliance.
Sorted disposal of electric and electronic equipment prevents the negative
effects on the environment and human health resulting from improper scrapping,
and also allows the materials from which it is made to be recovered and
recycled, with significant savings in terms of energy and resources.
The sorted disposal requirement is indicated by the crossed waste bin label
affixed to the appliance.
www.argoclima.com