MADE SA DETECT LINE NG High Voltage Detector Instruction Manual
- June 6, 2024
- MADE SA
Table of Contents
- General information
- Installation
- Materials
- Presentation
- Connections
- Alarm activation
- FCC statement §15.21
- FCC statement §15.105 a)
- General information
- Installation
- Materials
- Tests
- Technical visits
- Reminder on High Voltage lines
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Installation and
maintenance notebook
DETECT LINE NG
Attention: document to be filled during each installation. If the system is installed by you, thank you to return imperatively the double page of the middle (P9-10-11-12). Otherwise, the guarantee can not be taken into account.
In order to ensure the proper functioning of the system, preventive maintenance must be carried out every 24 months. Thank you to contact the company MADE for the establishment of a maintenance contract.
General information
Company Name: ………
Date of installation: ……
Name of the installer: ……
Installation
Installation support: …………
Vehicle registration: …………
Vehicle characteristics: ………
Materials
Central Unit case serial number: …………
UC : .……………Software version:……
Sensor:…………
……………………
……………………
Outside display unit:………
Security seal number:……
Positioning of the sensor on the support in the free area ▢Yes ▢No
If not, specify why the sensor is not in free field and the cause:
…………………………………
…………………………………
…………………………………
…………………………………
…………………………………
…………………………………
: MADE can’t guarantee the optimal functioning of the system.
For optimal operation, the sensor must be in a free field on the highest point
of the machine.
FI_CE_NG_DETECT_LINE_USB_FCC_V1_00US.docx
Presentation
DETECT LINE NG: High Voltage line volumetric detector: HVA (< 50 kV) and HVB
(> 50 kV).
DETECT LINE NG warns the user by an audible alarm when the lifting machine
enters a risk zone.
Central unit
Sensor management and control sensors, generation of audible and visual
alarms, movement blocking management (optional). Lamp « power on »
System in working order | Electric field present | Breakdown |
---|
– Lamp “Audible alarm” off
– Lamp “Movement cut” off
– Lamp “Visual alarm” off.
– Lamp “On work” light on steady.
- slow flash: system| – Lamp “Audible alarm” flashing*.
– Lamp “Movement cut” light on steady*
-Lamp “Visual alarm” light on steady
-Lamp “On work” light on steady.
– Buzzer on*.| – Lamp “On work” off power off
– slow flash: system waiting for alarm activation
– flashing fast: equipment fault.
Outside display unit
The outside display unit indicates the danger and allows acknowledging the audible alarm and the “Movement cut” (optional).
System in working order | Electric field present | Breakdown |
---|---|---|
– Lamp “Danger” off | – Lamp “DANGER” flashing*. | |
– Buzzer on*. | – flashing fast: equipment fault. |
Sensor
Sensor measures the electric field radiated by the High Voltage lines and communicates by wire connection with the CPU.
Connections
Full system connection:
Outside display unit present: | ▢Yes | ▢No |
---|---|---|
✓ Power supply of the central unit: | ||
Power: | ▢12V | ▢ 24V |
Indicate the place: | ||
--- | --- | --- |
✓Power supply after + PTO | ▢ Yes | ▢ No |
✓ Activation of alarms at power up | ▢ Yes | ▢No |
✓ Cut movement | ▢Yes | ▢No |
Indicate the place: ………………
Observations: …………………
Sensor wiring:
Use the M8 3-pin male connector for sensor wiring
Warning: the earth cable must be as small as possible. Use the Allen key supplied for the wiring
Number | Use |
---|---|
1 | CPU output, 5V power supply (white) |
3 | CPU input, sensor measurement (blue) |
4 | CPU output, mass (braid) |
Power supply, Cut-off, and alarm activation connection:
Pin number| Operation| Sick over-molded connector cable|
Cable 5x1mm² Black| Cable 5×0.5mm² Grey
---|---|---|---|---
1| Power 0V| Brown | Brown | Brown
2| Cut movement (in)| White | Green | Black
3| Power 12/24V| Blue | Blue | Blue
4| Alarm activation| Black | Black | Grey
5| Cut movement (out)| Grey | Yellow | Black
Example :
pinout connector
Alarm activation: factory configuration in + 12 / 24V
Display unit wiring:
Installation of the security seal at the end of the installation and testing:
Security seal | ▢ Yes | ▢ No |
---|
Alarm activation
To validate the alarm monitoring mode:
Version without PTO activation
Another way is to reverse the direction of bpext_sens using software « SNGU_Config_Vxxx »).
To activate the alarm monitoring mode, the control input must therefore be activated at ground potential (GND) or V + (12-24V). To do this, you must also configure the BPEXT_SENS option in the central unit (using the “Pc_SNG_Config_Vxxx” software)
Version: Signal Power take-off to ground
2 actions for configuration are to be performed: Position the switches on the CPU board Configure the option with the software
Version: Power take-off to 12-24V
2 actions for configuration are to be performed: Position the switches on the CPU board Configure the option with the software
FCC statement §15.21
The user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC statement §15.105 a)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help.
Pages (9-10-11-12) are to be sent back to the MADE company.
DETECT LINE NG
Installation and maintenance NoteBook
Attention: Page (9-10-11-12) to be filled during each installation, and
returned to us
Return the double page at the address:
MADE S.A.
167, Impasse de la garrigue
F 83210 LA FARLEDE
Phone : +33 (0) 494 083 198
Or by mail:
interventions@made-sa.com
Otherwise, the guarantee cannot be taken into account.
General information
Company Name: ……
Date of installation: ……
Name of the installer: ……
Installation
Installation support: ………
Vehicle registration: ………
Vehicle characteristics: ………
Materials
UC case serial number: …………
UC:…………….……Software version: .………
Sensor:……………..…
Display unit:………………
Security seal number:………………
Positioning of the sensor on the support in free area | ▢yes | ▢No*** |
---|
If not, specify why the sensor is not in free field and the cause:
……………………………
……………………………
……………………………
……………………………
……………………………
……………………………
*** : MADE can guarantee an optimal system.
For optimal operation, the sensor must be in a free field on the highest point of the machine.
Specify:
Outside display unit present: | ▢Yes | ▢ No |
---|---|---|
✓Power supply of the central unit: | ||
POWER: | ▢12V | ▢24V |
Indicate the place: | ||
✓Power supply after + PTO | ▢Yes | ▢No |
✓Activation of alarms at power up | ▢Yes | ▢No |
Other (specify) | ▢ | |
Indicate the place: | ||
✓Cut movement | ▢Yes | ▢No |
Indicate the place: | ||
Observations : |
Installation of the security seal at the end of installation and testing:
Security seal | ▢Yes | ▢No |
---|
Tests
✓Sensor test
Testeur TC HT
Use Testeur TC HT.
Otherwise, approach a 230V cable on the sensor.▢
✓ Display unit Test▢
✓ General control of functions: (bring an AC voltage source to the
sensor)
Audible alarms | ▢Yes | ▢No |
---|---|---|
Visual alarms | ▢Yes | ▢No |
In service | ▢Yes | ▢No |
MADE-SA:
Wiring done by
Name :|
Signature :|
Customer:
| Supply of the simplified form or the user guide| Basic training with
system explanation
---|---|---
Name :| |
**Signature :**| |
Observations:
………………………………………………
Tests
✓ Sensor test
Testeur TC HT
Use Testeur TC HT.
Otherwise, approach a 230V cable on the sensor.▢
✓ Display unit Test▢
✓ General control of functions: (bring an AC voltage source to the
sensor)| |
---|---|---
✓ Audible alarms| ▢ Yes| ▢ No
✓ Visual alarms| ▢ Yes| ▢ No
✓ In service| ▢ Yes| ▢ No
MADE-SA:
Wiring done by
Name :|
Signature :|
Customer:
| Supply of the simplified form or the user guide| Basic training with
system explanation
---|---|---
Name :| |
**Signature :**| |
Observations:
………………………………………………
Technical visits
Date | Comments |
---|---|
Work | Name/ Signature / Stamp |
--- | --- |
Date | Comments |
--- | --- |
Work | Name/ Signature / Stamp |
--- | --- |
Reminder on High Voltage lines
Reminder on the
Electrical lines
AN OPERATIONAL AID
Detection of powered overhead lines
from 20000Volts∼.
Warning :
The system is inoperative on:
- Low Voltage overhead power lines (380V)
- Medium voltage direct current power lines (trams, railways in general, ..)
The VIGILANCE and ATTENTION of the operator must remain maximum when approaching live power lines.
Electrocution can happen even without touching the line!
The different lines!
Safety distances
M A D E – SA
167, Impasse de la garrigue
F 83210 LA FARLEDE
Phone : +33 (0) 494 083 198
E-mail :contact@made-sa.com – Web : www
.made-sa.com
FI_CE_NG_DETECT_LINE_USB_FCC_V1_00US.docx
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>