Bestway 5838 Flowclear Pool Filter Pump with GFCI Plug Owner’s Manual
- June 5, 2024
- Bestway
Table of Contents
Bestway 5838 Flowclear Pool Filter Pump with GFCI Plug
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
WARNING-RISK OF ELECTRIC SHOCK- Never run the filter pump when people are
swimming in the pool.
The pump is to be supplied by an isolating transformer or supplied through a
residual current device (RCD) having a rated residual operating current not
exceeding 30 mA.
The power source on the wall of building should keep more than 4m away from
pool and at a height of 1.2m at least.
The pump unit must only be supplied at safety extra low voltage corresponding
to the marking on the appliance.
Extension cords can’t be used.
DO NOT BURY THE CORD. Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment.
WARNING-If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to
avoid a hazard.
WARNING-This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision. Cleaning and
user maintenance must be performed by an adult above 18 years old who is
familiar with the risk of electric shock.
The CAUTION-This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is
capable of being readily disassembled for storage and reassembled to its
original integrity. A permanently-installed pool is constructed in or on the
ground or in a building such that it cannot be readily disassembled for
storage. IMPORTANT- Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRICAL SHOCK- Before removing, cleaning, serving or making any
adjustment to the product, always unplug this product from the electrical
outlet.
DO NOT MODIFY THE PLUG IN ANY WAY OR USE PLUG ADAPTORS TO CONNECT UNIT TO
ELECTRIC SUPPLY.
Handle the pump with care. Do not pull or carry the pump by the power cord.
Never pull a plug from the outlet by yanking the power cord. Keep cord free
from abrasions. Sharp objects, oil, moving parts, and heat should never be
exposed to the filter pump.
NOTE:
Please examine equipment before use. Notify Bestway at the customer service
address listed on this manual for any damaged or missing parts at the time of
purchase. Verify that the equipment components represent the filter pump model
that you had intended to purchase.
NOTE:
Place pump on solid and level ground. Pay attention to the position of the
pool and pump so adequate ventilation, drainage, and access for cleaning is
available. Never place a pump in an area that may accumulate water, or in an
area where foot traffic will flow around the pool.
It is necessary to have the plug accessible after the installation of the
pool. NOTE:
Keep the transformer away from the pool and the filter pump for more than
3.5m. NOTE:
Atmospheric conditions may affect the performance and life span of your filter
pump. Unnecessary wear and tear may occur during periods of cold, heat, and
exposure to sun. Whenever possible shelter pump from these conditions. It is
important to ensure the factory-equipped stopper plugs for the inlet and
outlet ports replace the screens before removal or maintenance on the pump is
attempted.
NOTE:
- Do not add chemicals in the filter pump.
- Don’t plug or unplug the appliance if the hand is wet.
- Always unplug the appliance:
- On raining days
- Before cleaning or other maintenance
- Leave it unattended on holidays
When the appliance will be not used for a long time, such as in the winter, the pool set should be disassembled and stored indoor.
CAUTION – Read the instruction before using the appliance and
installation/reassembly every time.
Safekeeping the instruction. For reconstruction of the pool set every time,
please always refer to the instructions.
If the instruction is missed, please contact Bestway or search it in the
website: www.bestwaycorp.com
Electric installations should follow national wiring rules. Consult a
qualified electrician for any questions.
Only the media provided or specified by the manufacturer is to be used with
product installation.
It is essential to check that the suction openings are not obstructed.
It is advisable to stop the filtration during maintenance operations on the
filtration system.
Regularly monitor the filter clogging level.
A weekly check is recommended for cleaning.
Minimum daily filtration operating time of 8 hours is recommended to ensure
clear pool water.
It is essential to change any damaged element or set of elements as soon as
possible. Use only parts approved by person responsible for placing the
product on the market. All filters and filter media shall be inspected
regularly to ensure that there is not a build-up of detritus thus preventing
good filtration. The disposal of any used filter media should also be in
accordance with applicable regulations/legislation.
In case of doubt on the pump or any circulation devices, contact a qualified
installer, or the manufacturer/importer/distributor.
The water circulation installation shall comply with the European as well as
national/local regulations, especially when dealing with electrical issues.
Any change of valve position, pump size, grille size can cause a change of the
flow and the suction velocity can be increased.
Mind all the safety requirements and recommendations described in the manual.
NOTE: This product is not intended for commercial use.
Please read the instruction manual carefully and keep it for future reference.
SAVE THESE INSTRUCTIONS.
PEDESTAL FIXING Fig.1
EN60335-2-41 TEST standard requires the filter pump to be vertically fixed on
ground or a certain pedestal made of wood or concrete before use. There should
be two holes 9mm in diameter on the pedestal, the space between which should
be 160mm. Put filter pump on the pedestal and fix them together by fasten the
bolts and nuts. All the pedestal parts should weigh over 18kgs at least to
prevent the pump from accidentally falling.
Operation
- Open/unscrew the Air Purge Valve on the top of the Filter Pump; air is released as water fills the Filter Pump.
- When water comes out of the Air Purge Valve screw it closed and wipe away any water.
- To start the Filter Pump, insert the plug into a residual current device (RCD).
- To start the Filter Pump, insert the plug into a circuit of alternative residual power (DDR) For France Only.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP –
Make sure both the pool’s Inlet and Outlet valves are fully covered by water
before operating the Filter Pump.
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
- Unplug the Filter Pump.
- Stop water flowing to the Filter Pump refer to the pool’s manual.
- Unscrew the Filter Cap Retainer and remove the Filter Cap.
- Clean the Filter Cartridge with a garden hose.
- Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
- Check that the Filter Cap Seal is in place.
- Replace the Filter Cap and screw the Filter Cap Retainer into position.
- Open the valve A and B.
- Follow the Pump Installation Directions section to prepare the system for use.
IMPORTANT: For sanitary reasons, we suggest replacing the Filter Cartridge with a new one every two weeks. Flush the filter daily.
Winterization and long-term storage
- Unplug the Filter Pump.
- Stop water flowing into the Filter Pump and to remove the Filter Cartridge.
- Discard the Filter Cartridge.
- Detach all Hoses.
- Dry all components thoroughly.
- Store the filter pump in a dry location out of child’s reach. Storage temperature: 4-40 °C(39,2-104 F)
- Drain the pool according to the Pool Owner’s Manual.
PUMP WARRANTY
For information concerning pump warranty please visit our website at:
www.bestwaycorp.com
PUMP DISPOSAL
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.