WARNING!
- RISK OF ELECTRIC SHOCK Always disconnects the mains power supply before inspection or replacement.
- The source of light shall be replaced by the manufacturer, its authorized representative or a properly qualified person only.
RISK OF FIRE
- Proceed in accordance with local safety regulations.
- Use only UL and IEC-certified cables for connections.
- The lighting fixture shall be fixed in such a way so as to avoid prolonged and direct eye exposure to the light source from a distance of 0,23m or less.
ELECTRICAL REQUIREMENTS
- TRI-PROOF LED has to be connected to the mains power supply in accordance with instructions on the box.
- Protection class II
INSTALLATION
Please read the following instructions carefully to ensure the fixture is installed properly. We strongly recommended that you keep these instructions for future reference.
PRODUCT SPECIFICATION
3 years warranty
MODEL: | 477606 | 477613 | 477620 | 477637 |
---|---|---|---|---|
POWER: | 30W | 40W | 70W | 90W |
COLOUR TEMPERATURE: | 4000K | 4000K | 4000K | 4000K |
POWER FACTOR: | > 0.9 | > 0.9 | > 0.9 | |
VOLTAGE RANGE: | 185-265V | 185-265V | 185-265V |
185-265V
FREQUENCY:| 50-60Hz| 50-60Hz| 50-60Hz| 50-60Hz
LUMINOUS FLUX:| 3600Im| 4800Im| 8400Im| 10800Im
EFFICACY:| 120Im/W| 120Im/W| 120Im/W| 120Im/W
IP PROTECTION CLASS:| IP65| IP65| IP65| IP65
ENERGY CLASS:| E| E| E| E
Safety instructions
- Use flexible rubber cable H07RN-F, 2xl, Omm2
- The fixture should only be installed by an authorized electrician in accordance with national wiring laws and regulations
- If external flexible cable or the main power cord becomes damaged, only the manufacturer, its service agent or a suitably qualified person shall replace the fixture to avoid any risk of electric shock or prevent further damage.
- Power supply shall be disconnected prior to any installation, repairs or maintenance works being carried out.
- Unscrew the cable gland’s nut fig.1
- Insert the round electric wire through the unscrewed gland fig.2
- Connect the electric wires with the use of quick-connect fitting. Press the quick-connect fitting button and insert the phase wire (brown L) into the L terminal and the neutral wire (blue N) into the N terminal.
- Make sure the wires are connected correctly and subsequently screw in the cable gland fig. 3
Minimum distance from the illuminated object: lm
RESPONSIBLE ENTITY
LEDIN Sp. z o.o. Sp.K. UI. Debowa 1, 07-410, Tobolice. NIP:7582278888
Disposal
This device is labeled with a crossed-out wheeled bin symbol with a single black line underneath (WEEE), as prescribed by the European Community Directive 2012/19/UE of 04.07.2012 and in accordance with The Waste Electrical and Electronic Equipment Act of 11 September 2015. This symbol indicates that the device may not be disposed of with other household waste. The user is responsible for the disposal of this equipment through a designated UWEEE” collection points, such as local collection points, stores or designated local authority bodies. This policy is intended to promote greater efficiencies in the management of WEEE disposal and to enforce the protection of the environment and human health.