LEDOM 477613 30W Tri-Proof Hermetyczna Interier Lamp User Manual

June 5, 2024
LEDOM

LEDOM 477613 30W Tri-Proof Hermetyczna Interier Lamp

LEDOM 477613 30W Tri-Proof Hermetyczna Interier Lamp
pro

RETAIN THE MANUAL FOR FUTURE REFERENCE

Use the product as intended by the manufacturer. If you have any questions contact the manufacturer.

WARNING!

  1. RISK OF ELECTRIC SHOCK  Always disconnects the mains power supply before inspection or replacement.
  2. The source of light shall be replaced by the manufacturer, its authorized representative or a properly qualified person only.

RISK OF FIRE

  1. Proceed in accordance with local safety regulations.
  2. Use only UL and IEC-certified cables for connections.
  3. The lighting fixture shall be fixed in such a way so as to avoid prolonged and direct eye exposure to the light source from a distance of 0,23m or less.

ELECTRICAL REQUIREMENTS

  1. TRI-PROOF LED has to be connected to the mains power supply in accordance with instructions on the box.
  2. Protection class II

INSTALLATION

Please read the following instructions carefully to ensure the fixture is installed properly. We strongly recommended that you keep these instructions for future reference.

PRODUCT SPECIFICATION

3 years warranty

MODEL: 477606 477613 477620 477637
POWER: 30W 40W 70W 90W
COLOUR TEMPERATURE: 4000K 4000K 4000K 4000K
POWER FACTOR: > 0.9 > 0.9 > 0.9
VOLTAGE RANGE: 185-265V 185-265V 185-265V

185-265V
FREQUENCY:| 50-60Hz| 50-60Hz| 50-60Hz| 50-60Hz
LUMINOUS FLUX:| 3600Im| 4800Im| 8400Im| 10800Im
EFFICACY:| 120Im/W| 120Im/W| 120Im/W| 120Im/W
IP PROTECTION CLASS:| IP65| IP65| IP65| IP65
ENERGY CLASS:| E| E| E| E

Safety instructions

  1. Use flexible rubber cable H07RN-F, 2xl, Omm2
  2. The fixture should only be installed by an authorized electrician in accordance with national wiring laws and regulations
  3. If external flexible cable or the main power cord becomes damaged, only the manufacturer, its service agent or a suitably qualified person shall replace the fixture to avoid any risk of electric shock or prevent further damage.
  4. Power supply shall be disconnected prior to any installation, repairs or maintenance works being carried out.
  5. Unscrew the cable gland’s nut fig.1
  6. Insert the round electric wire through the unscrewed gland fig.2
  7. Connect the electric wires with the use of quick-connect fitting. Press the quick-connect fitting button and insert the phase wire (brown L) into the L terminal and the neutral wire (blue N) into the N terminal.
  8. Make sure the wires are connected correctly and subsequently screw in the cable gland fig. 3LEDOM 477613 30W Tri-Proof Hermetyczna Interier Lamp 1

Minimum distance from the illuminated object: lm

RESPONSIBLE ENTITY

LEDIN Sp. z o.o. Sp.K. UI. Debowa 1, 07-410, Tobolice. NIP:7582278888

Disposal

This device is labeled with a crossed-out wheeled bin symbol with a single black line underneath (WEEE), as prescribed by the European Community Directive 2012/19/UE of 04.07.2012 and in accordance with The Waste Electrical and Electronic Equipment Act of 11 September 2015. This symbol indicates that the device may not be disposed of with other household waste. The user is responsible for the disposal of this equipment through a designated UWEEE” collection points, such as local collection points, stores or designated local authority bodies. This policy is intended to promote greater efficiencies in the management of WEEE disposal and to enforce the protection of the environment and human health.LEDOM 477613 30W Tri-Proof Hermetyczna Interier
Lamp 2

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals