FRANKEVER FKV02 Smart Water Valve User Manual

June 5, 2024
FRANKEVER

FRANKEVER FKV02 Smart Water Valve

Product Description

Summary

  • DC 5V/2A power supply by adaptor
  • Mobile APP using MCU microcomputer control technology
  • Timing regularly closing and multi-angle opening function
  • Waterproof: IP67
  1. Model No.: FK-V02

  2. Materials: SS304 & Engineering Plastics

  3. Valve Size: DN15,DN20,DN25,DN32

  4. Screw Thread: NPT BSP

  5. Max pressure: 1.0Mpa

  6. Input Voltage: DC5V

  7. Support Ambient Temperature:-30℃~60℃

  8. Frequency of Timing:
    Unlimited times per day, the interval between the maximum period is once a week.

  9. Controller Operation:
    App manual control, Field manual operation, APP cloud timing, Countdown

Product Specffication

INPUT; DCSV/2A

OUTPUT: APP Interlace

Use waterproof Aviation socket, safe and secure

  1. Use Aviation socket, safe and secure.FRANKEVER-FKV02-Smart-Water-Valve-4
  2. With a USB interface, the user needs to match a 5V2A adapter (the adapter of the phone can also use)

Key Function

Link WIFI
Long press for 5 seconds: link WIFl and mobile phone to
match network

Local Operation Function:

  • When the water valve is in the closed position. press the (setting button) water valve to open the position operation until the fully open position.
  • When the water valve is in the open position, press the (setting button) water valve to close the position operation until it the fully closed position.

Installation Tutorial For WiIFi type water valve

Download APP “Smart Life” and Register as MemberFRANKEVER-FKV02-Smart-Water-
Valve-6

  1. Enter to the APP and press”+” at the upper right to add new item.
  2. Press” Add Manually” -“Gateway and others””Connector(- Wi-Fi) ” to add a new item.

Be careful
Keep the device as close to the router as possible.FRANKEVER-FKV02-Smart-
Water-Valve-7

  1. Connet the item as picture showed.

  2. Set to link WIFI
    Note: The name and The password must be right for the WIFIFRANKEVER-FKV02
-Smart-Water-Valve-8FRANKEVER-FKV02-Smart-Water-
Valve-9

  3. The matching interface of device and APP

  4. Connected successfully

(Ensure you have Zigbee gateway together, which is requested to use together with our water valve)

Download APP “Smart Life” and Register as MemberFRANKEVER-FKV02-Smart-
Water-Valve-10

  1. Enter the App and press “+” in the upper right corner to add the gateway
  2. Choose “Others(Zig-bee)” from the “Other” area.FRANKEVER-FKV02-Smart-Water-Valve-11
  • Paring with gateway when the red led light in quickly flash
  • After gateway paring done, enter into the main page of Gateway, continue to add the water valve from “Add Subdevice”

Ensure the water valve blue light in quickly flash, then press”More device reset methods”FRANKEVER-FKV02-Smart-Water-Valve-12

Press “Others” and start to pair, until you see the water valve on your reparing page, then its done.FRANKEVER-FKV02-Smart-Water-
Valve-13

Performance Specification

  1. Turn On and Off Function
  2. APP Control
  3. APP Cloud Timing Function
  4. Power Failure Protection Function
  5. Automation Function

Turn On and Off Function

Water valve close:
From open to close (0%) accuracy is 5%

Water valve open:
From close to open fully (100%) accuracy is 5%

Controlled by button or mobile app

APP Control

Countdown Function

Click the Countdown button to set the watering time you need

APP Cloud Timing Function (Schedule function)

Cloud Timing Opening

  1. Set Start or End Time
  2. Set Valve Position according to your needs
  3. Set finished

Cloud Timing Success Interface
(unlimited frequency)

Fault Alarm Function

Power Failure Protection Function:
If the power is cut off suddenly, the water valve will automatically close within 2 seconds

Automation Function
How to use automation function with smart water leak sensor: (Kindly notice: make sure your water sensor is in the same protocol as the water valve. Zigbee water valve request Tuya Zigbee water sensor, and our wifi water valve request Tuya wifi water sensor! ).

Step 1:
Make sure you already paired the water sensor and water valve in the same app successfully.

Step 2:
Press “ smart” then on the “Automation” page. Then press “+” at the upper right corner to create a task

Step 3:
Set a condition on the water leak sensorFRANKEVER-FKV02-Smart-Water-
Valve-21

Step 4:
Set up a task for the water valve, then you can see the task details, and the water valve will do action automatically.FRANKEVER-FKV02-Smart-Water-
Valve-22

Steps For The Device To Be Shared With Other Members Cwho are already members):

After the steps are completed as shown in the following figure will be sent a system message to the person with who you are sharing. then they just need to confirm to join.

Group Function:
Follow the steps below to add any device to your app. you can also name it arbitrarily.

FCC STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To maintain compliance with FCC’s RF exposure guidelines, This equipment should be installed and operated with a minimum distance of 20cm from the radiator of your body: Use only the supplied antenna.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals