XAC AT-100 Series Terminal Payment Device Installation Guide
- June 5, 2024
- XAC
Table of Contents
**XAC AT-100 Series Terminal Payment Device Installation Guide
**
This symbol is intended to alert the user before starting using the POS. Before using the Device.
- Please do the full charge (0% ~ 100%) once to get the best battery
- Please ensure the unit was not stored for over one month without charging.
- Battery life will depend on different use-cases and the battery manufacturer recommends replacing it with a new one every 2 years.
Caution: Do not attempt to open and disassemble the device, that will cause device tamper.
PACKAGE CONTENT
DEVICE OVERVIEW
Device Overview (Figure 1):
FRONT AREA | 1 | Printer Paper Cover |
---|---|---|
2 | 4” Display | |
3 | Magnetic Strip Reader (MSR) slot | |
4 | Power Button (Press > 3 seconds to power on/off) | |
5 | Smart Card Reader (SCR) slot | |
REAR AREA | 6 | Charging contact points |
7 | USB port (type C) for charging | |
8 | Camera for 1D/2D barcode scanning (Optional) | |
9 | Battery Compartment |
AT-100 Power spec:
Input: 5V DC, 2A
Power Adapter spec:
Input: 100 ~240 Vac
Output: 5V DC, 2A
Caution: Use only the AC adapter approved and provided by XAC Automation
Corporation for use with this device. Use of any other AC adapter may cause a
risk of fire or explosion.
Operating Temperature: 0
POWER ON/OFF THE DEVICE
To power on the device: Long press the Power button (Figure 2) > 3 seconds and
the device screen will be activated.
To power off the device: Press the Power button > 3 seconds to shut down the
device.
NOTE: When device is in idle or suspend mode, short press power button will wake up the device.
USING THE MAGNETIC CARD READER
Swipe the card through the slot with magnetic stripe side facing the same direction as the display. (Figure 3)
USING THE IC CARD READER
Insert an IC card into the slot (Figure 4) with the chip side facing the same direction as the touch panel (Figure 5).
SING THE KEY PAD
After inserting the chip card, Press the numeric key as below keypad (Figure 6) to enter the desirable numbers. Press Cancel (X) key to terminate any current function and press the Enter (O) key to confirm a value or an option.
USING THE CONTACTLESS CARD READER
Tap the contactless card on top of the contactless logo (Figure 7).
REPLACE THE BATTERY
REMOVE THE BATTERY
STEP 1: Push the latch to pull the battery cover from AT-100 as Figure 8.
STEP 2: After removing the battery cover, pull up the battery connector as
below Figure 9 to change a new battery.
INSTALL THE BATTERY
STEP 1: Insert the battery connector into AT100 with correct direction as
Figure 10.
STEP 2: After install the battery, close the bottom cover as Figure 11.
**** Bottom Cover Removal Warning
When removing the bottom cover and screws for the purposes of changing
battery, remember to put back the cover and screws before power on the POS.
CAUTION:
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS.
Warning for internal battery pack
To reduce risk of fire or burns:
- Do not attempt to open, disassemble, or service the battery pack.
- Do not crush, puncture, short external contacts, or dispose of in fire or water.
- Do not heat above 60 C
**** Installing the battery
- After install the battery, please make sure the battery is fitted properly into the battery compartment.
- Please do the full charge (0% ~ 100%) once to get the best battery performance after battery replacement.
Note: The battery is considered a consumable item and excluded from XAC’s Product Warranty.
INSERT SAM/SIM CARD
After removing the battery, the user can find SAM2 (left) slots and SIM2(right) slot at the bottom side of device. Please insert the card correctly as the icon shown on the cover as Figure 12:
LOADING THE PAPER
Gently pop the printer cover’s latch; then pull the cover (Figure 13). Load a roll of thermal paper into the printer. Load it so that the print-side of the paper will feed out facing the operator. Close the cover by pressing on the center of the printer cover. Use the serrated bar to tear off any excess paper.
FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT (Only for xCL_AT-100-R3-18U)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Radiation Exposure Statement:
The product comply with the FCC portable RF exposure limit set forth for an uncontrolled environment and are safe for intended operation as described in this manual. The further RF exposure reduction can be achieved if the product can be kept as far as possible from the user limb or set the device to lower output power if such function is available.
Specific Absorption Rate (SAR) Testing Your device has been designed to comply
with applicable limits for RF exposure. These limits use a unit of measurement
called Specific Absorption Rate, or SAR, which refers to the rate at which the
limb absorbs RF energy. The Federal Communications
Commission (FCC) has established a SAR limit for mobile phones of 1.6 W/kg,
which applies in the United States and other countries that follow the FCC’s
SAR limit.
SAR testing is conducted with the device placed in common operating positions (e.g., held against the head, worn on the limb) and transmitting at its highest certified power level in each frequency band of operation. Because the device is transmitting at its highest certified power level, SAR tests capture a worst-case operating scenario and therefore often do not reflect the amount of RF exposure during normal, everyday use.
More information on SAR testing is available on the FCC’s website at http://www.fcc.gov/guides/ wireless-devices-and-health-concerns.
XAC Automation Corporation submitted SAR test results demonstrating compliance with the FCC’s SAR limit for wireless devices as part of the FCC’s equipment certification process for this device. These results can be accessed via the FCC’s equipment authorization database (found at http://transition.fcc.gov/oet/ea/fccid/) by searching for the device’s FCC ID: MQT-AT100R3.
XAC Automation Corporation
886-3-577-2738
www.xac.com.tw
The above information is the exclusive intellectual property of XAC Automation
Corporation and shall not be disclosed, distributed or reproduced without
permission of XAC Automation Corporation.
XAC AUTOMATION CORP. shall not be held liable for technical and editorial
omissions or errors made herein; nor for incidental or consequential damages
resulting from the furnishing, performance or use of his material.
Read User Manual Online (PDF format)