Model No.: E1-H + ER, E1-H + EC, E1-H + ED, E1-H + EB, E1-H + EM1 5 sensor detector/RF AC Switch/Relay output/Max 3A/Wall junction box mounting

Features

  • Sensor + RF smart switch with relay output, without dimming function.
  •  Input connect with 5 kinds of sensor detector optional, output connected directly to single color LED lamps, traditional incandescent, halogen lights or other electrical equipment.
  •  Match with RF 2.4G dimming remote control optional, except PIR motion sensor input.
  •  Each smart switch can also work as Sensor – RF signal converter, control one or more another RF LED controller synchronously.
  •  PIR motion sensor: when people or objects enter the sensitive field, turn on the switch; when these exit the sensitive field, turn off the switch after 30 seconds.
  •  Touch sensor: short touch to turn on or turn off the switch.
  •  Door sensor: when the door open, or no obstacle ahead, turn on the switch; when the door close, or obstacle ahead, turn off the switch.
  • Hand sweep sensor: when hand sweep, turn on the switch; when hand sweep again, turn off the switch.
  •  Microwave motion detector: turn on the switch upon detection of motion, and turn off after a pre-selected hold time when there is no movement.
  •  Microwave motion detector, built-in daylight sensor, detection area, time delay and daylight threshold can be set via knob potentiometer for each specific application.
  •  Easy to be placed in standard wall junction box.

Technical Parameters

Input and Output

Input voltage| AC100-240V
Output voltage| AC100-240V
Output current| Max 3A
Output power| 300-720W
Input signal| Sensor + RF 2.4GHz
RF Control distance| 30m(Barrier-free space)
Safety and EMC

EMC standard (EMC)| ETSI EN 301 489-1 V2.2.3

ETSI EN 301 489-17 V3.2.4

Safety standard(LVD)| EN 62368-1:2020+A11:2020
Radio Equipment(RED)| ETSI EN 300 328 V2.2.2
Certification| CE,EMC,LVD,RED
Environment

Operation temperature| Ta: -30 OC ~ +55 OC
Case temperature (Max.)| T c: +65OC
IP rating| IP20

Mechanical Structures and Installations

ER: PIR Motion Sensor

When people enter the sensitive field, the switch turn on. When people exit the sensitive field, the switch turn off after 30 seconds.

EC: Touch Sensor

ED: Door Sensor

When the door open, or no obstacle ahead, the switch turn on. When the door close, or obstacle ahead, the switch turn off.

EB: Hand Sweep Sensor

When hand sweep, the switch turn on. When hand sweep again, the switch turn off.

EM1: Microwave Sensor Switch

This sensor is a motion switch, which turn on the light upon detection of motion, and turn off after a pre-selected hold time when there is no movement.

  1. With sufficient ambient light, the sensor does not turn on the light.
  2.  With insufficient ambient light, the sensor turn on the light when motion is detected.
  3. After hold time, the light turns off if no motion detected.

**Sensor setting

**

By selecting the combination on knob potentiometer, sensor data can be precisely set for each specific application.

Detection area:
The detection area can be reduced by rotate knob to fit precisely each application.
Hold time:
Refers to the time period remains light on state after no motion detected.
Daylight sensor:
The sensor can be set to only allow the lamp to illuminate when below a defined ambient brightness threshold.  sensor will switch on the lamp when motion is detected regardless of the ambient light level. 50lux: twilight operation. 30 lux: evening operation. 10 lux: darkness operation.
Note that the daylight sensor is active only when lamp totally switches off, and the ambient lux level refers to internal light reaching the sensor.

Setting on this demonstration:

Detection area: 50% Hold time: 90S Daylight sensor: 50lux

Wiring diagram

  1.  Load current < 3A

Note:
If output connect with capacitive or inductive load, the maximum output current only up to 3A. If output connects with resistive load, the maximum output current may up to 10A. Load current > 3A

Note:
An additional AC relay or contactor is needed when total input current of the load (such as pump) is higher than 3A or inrush current is greater than 30A.

Match Remote Control (Optional)

The smart switch can match with RF 2.4G dimming remote control optional, except PIR motion sensor input. For PIR motion sensor input, please long press the MATCH key 10s to disable the RF remote match function. For other sensor input, please long press the Match key 5s to enable the RF remote match function.End user can choose the suitable match/delete ways. Two options are offered for selection:

Use the MATCH key
Match:
Short press MATCH key, immediately press on/off key (single zone remote) or zone key (multiple zone remote) of the remote.
Delete:
Press and hold MATCH key for 5s to delete all match, The light blinks 5 times means all matched remotes were deleted.

Use Power Restart
Match:
Switch off the power, then switch on power, repeat again. An immediately short press on/off key (single zone remote) or zone key (multiple zone remote) 3 times on the remote.
Delete:
Switch off the power, then switch on power, repeat again. An immediately short press on/off key (single zone remote) or zone key (multiple zone remote) 5 times on the remote.

Work as Sensor-RF signal converter to match other RF LED controller

(Optional)

The smart switch can also work as Sensor – RF signal converter, control one or more another RF LED controller synchronously. When short press the ON/OFF key on the smart switch, the relay output turn on or turn off, also send out RF on/off signal. End user can choose the suitable match/delete ways. Two options are offered for selection. When the match is done, the sensor signal will also control the matched RF LED controller.

Use the controller’s Match key
Match:
Short press match key of the controller, immediately press ON/OFF key on the smart switch. The LED indicator fast flash a few times means match is successful.
Delete:
Press and hold match key of the controller for 5s, The LED indicator fast flash a few times means match was deleted.

Use Power Restart
Match:
Switch off the power of the controller, then switch on power, repeat again. Immediately short press ON/OFF key 3 times on the smart switch. The light blinks 3 times means match is successful.

Delete:
Switch off the power of the controller, then switch on power, repeat again. Immediately short press ON/OFF key 5 times on the smart switch. The light blinks 5 times means match was deleted.

Microwave Sensor Detection Pattern

Wall mounting pattern(Unit:m) Suggested installation height: 1-1.8mWall mounting pattern(Unit:m) Suggested installation height: 1-1.8m

Microwave Sensor User recommended settings

Settings

Scenarios

| Detection distance| Hold time| Daylight sensor
---|---|---|---
Passage, staircase| 4-6m| 10s| Twilight(50lux) / Darkness(10lux)
Balcony, corridor| 4-6m| 10s| Twilight(50lux) / Darkness(10lux)
Cloakroom, storeroom| 2-3m| 90s| Evening(30lux)
Garage| 2-3m| 90s| Evening(30lux)
Kitchen| 3-4m| 90s| Evening(30lux)
Dinning room| 3-4m| 3min| Evening(30lux) / Twilight(50lux)
Toilet| 2-3m| 3min| Daytime(>50lux) / Evening(30lux)
Meeting room| 2-3m| 10min| Evening(30lux)
Indoor public access| 4-6m| 10min| Daytime(>50lux)
Underground public access| 4-6m| 10min| Daytime(>50lux)

Microwave Application Notice

  1.  The sensor is designed for indoor use only. The raining or wind blowing may trigger the microwave sensor even if without human motion when outdoor use.
  2. The sensor should be installed by a professional electrician. please turn off the power before installing, wiring and changing setting of the knob.
  3.  The distance between any two sensors should be at least 3m to avoid interference each other.
  4. When the microwave sensor is installed in a metal lighting fixture or space with large reflector, for example a warehouse with metal roof, the microwave signal will be reflected and cause the lights permanent illuminated even if without motion signal. Please reduce the detection area to solve the problems.
  5. Make sure the sensor not close to or be blocked by high density materials, such as metal, glass, concrete walls etc. The materials will reduce or block microwave signal and cause false trigger.
  6. The sensor which installed in the plastic and glass lampshade will reduce th sensitivity. For every 3mm increase in thickness, the sensitivity will be reduced by 20%.
  7. The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection. Ambient lux level could be different in a different environment, weather, climate, time-of-delay and season.
  8. Make sure there are no fans, DC motor, or other vibrating objects in the installation area. The movement will trigger sensor as well.