smartrol-iot P10 433MHz Pet-immune Wireless Infrared Motion Detector User Guide
- June 5, 2024
- smartrol-iot
Table of Contents
PIR Motion Sensor
USER GUIDE
In The Box
| PIR Motion Sensor
Senses when someone walks nearby
---|---
| PIR Motion Sensor Bracket
For PIR motion sensor installation
| Screws x 2
For PIR motion sensor installation
| User Guide
At a Glance
Bottom view
Inside view
How to Install
Mounting height
Motion sensor must be mounted 79 to 87 inches(2 to 2.2m) above the floor.
Mount the bracket with the included screws as shown above. Then place the
motion sensor in the bracket. Specify the right direction of the detection
range of the motion sensor. Test the operation of the motion sensor by putting
it into testing mode which has been described at the former page.
Detection Area
Side view
Special considerations
- Don’t install PIR Motion sensor outdoors, in a garage, and on the glass.
- PIR Motion Sensor can’t detect motion through glass, like if someone’s moving outside a window.
- Don’t install in places where PIR Motion Sensor could get wet, like swing-out windows that could be rained on.
- Don’t install PIR Motion Sensor within 3 feet (1 meter) of a heat source like an electric heater, heat vent or fireplace, or another source that may produce turbulent air.
- Don’t install PIR Motion Sensor behind large appliances or furniture that may obstruct its motion sensors.
Walking Test
Setting Jumpers OPEN CLOSED
Setting the Pulse Counter (PULSE2 & PULSE1 jumpers)
The motion sensor is equipped with a programmable pulse counter which can be
set to count 1,3 or 5 pulses.
Place the pulse count jumpers at the desired setting as shown below.
Working mode (TEST & NORMAL jumpers)
To save battery power in normal use, if the sensor is triggered twice within 3
minutes, it enters sleeping state immediately. During this period, any
movement detected does not generate an alarm. After no movement within the
next 3 minutes, it goes back to working state again.
- For effective walk testing, set jumpers as shown on the right.
- When walk testing is done, set jumpers to save power as shown on the right.
LED jumper
CLOSED enables LED on.
Specifications
Power Supply: | 1.5V AA Battery x3 |
---|---|
Standby Current: | <15uA |
Alarm Current: | <25mA |
Pet Immunity: | <15kg |
Detection Scope: | <12m/110° |
Transmitting Distance: Interference) | <80m (Open Area and No |
Radio Frequency: | 433Mhz |
Operation Temperature: | 0~55℃ |