IMPLEN CFR21 NanoPhotometer Software User Manual
- June 5, 2024
- IMPLEN
Table of Contents
NanoPhotometer® CFR21 Software
User Manual
Version 2.1
Software Version 4.6.16350
NanoPhotometer® CFR21 Software User Manual Version 2.1
The end-user of the NanoPhotometer ® product (“End User”) hereby takes full responsibility for the safe storage and backup of all files and/or data that may be created, saved on, or transferred from the device. End-User acknowledges that it is possible that data and/or files may be lost or damaged, and further acknowledges and agrees that it has sole responsibility to maintain all appropriate backup of files and data. By using the NanoPhotometer ® device, the End User hereby agrees to these terms and agrees that Implen shall not be held liable for any loss, deletion, or damage of any data or files for any reason, including any damages attributable thereto.
Telephone support is available using one of the following phone numbers from your geographic region:
Europe, Asia, South Pacific, Middle East, Africa
Phone: +49 89 72637180
Fax: +49 89 726371854
Email: info@implen.de
Website: www.implen.de
Implen GmbH
Schatzbogen 52
81829 München
Germany| North and South America
Phone: +1 818 748 6400
Fax: +1 818 449-0416
Email: info@implen.com
Website: www.implen.com
Implen, Inc. Unit 104
31194 La Baya Drive
Westlake Village, CA 91362
USA
---|---
Windows and Excel are trademarks of Microsoft Corporation Redmond, WA macOS is a trademark of Apple Inc. Cupertino, CA
OVERVIEW
The CFR21 software complies with FDA 21 CFR part 11 requirements and is an
optional software tool ideal for GxP laboratories, which require proper
electronic record keeping. It includes user management, access control,
electronic signatures, data integrity, security, and audit trail
functionality.
Note: This CFR21 Software user manual does not describe the general
functionality of the NanoPhotometer ®. The CFR21 software user manual is to be
used in conjunction with the NanoPhotometer ® user manual.
User Management
Individual Role-Based Access Control (RBAC) provides password-protected access
and control of the NanoPhotometer ®. Create multiple user accounts with
different access rights which are handled in a hierarchic structure. User role
options are Administrator, Power User, and User. Organize users into working
groups to facilitate access to shared data and stored methods within a lab.
There is also an option for increased transparency with Four Eye
Authentication. Various password settings are available within the CFR21
Software – for example, secure password and password expiration options.
Effectively improve data security and fulfill audit requirements easily with
flexible and appropriate RBAC user management solutions. All features can be
enabled or disabled on demand to meet your laboratory needs.
Electronic Signature
Measurement data can only be saved when confirmed with user ID and password by
the logged-in user. All saved files include the user name/author, date, and
time of saving for proper electronic records. IDS and PDF files cannot be
altered and ensure data integrity.
Audit Trail
The audit trail automatically records all actions and preference changes in an
audit log. The audit log contains a log ID, timestamp, user ID, and category
for each action. Audit trails can be exported by an Administrator for
documentation purposes. Power Users can read the audit trail but are not
allowed to save it.
Important Compliance Information
The NPOS Software, containing the activated CFR21 Software, in conjunction
with your company’s SOPs can assist you in complying with FDA 21 Part 11
requirements. Your company must ensure that all aspects of the FDA regulations
are maintained. Compliance may include (but is not necessarily limited to):
- Validating your NanoPhotometer®.
- Access control and proper documentation.
- Determining that the system users have the knowledge, training, and experience required to perform their assigned tasks.
- Verifying the identity of each user.
- Restricting user accounts appropriately.
- Requiring a periodic change of account passwords.
- Certifying the use of electronic records and electronic signatures to the FDA.
- Configuring the CFR21 software consistently with your intended use.
- Establishing and following conforming SOPs.
Note: For more information on complying with the FDA 21 CFR Part 11 requirements, refer to the FDA website: http://www.fda.gov.
CFR21 SOFTWARE ACTIVATION
The CFR21 software is part of the installed NPOS Software. No further
installation is necessary. Activation of the CFR21 Software is only possible
with a serial number-related license file (NPOS.lic).
Note: The purchased license file for the CFR21 software is stored on the
Implant USB flash drive included in the NanoPhotometer delivery. The CFR21
Software is available for NanoPhotometer ® N120/NP80/N60/C40.
Note: The CFR21 Software is not available for NanoPhotometer ® N50 and
control devices like tablets and smartphones.
ENABLING CFR21 SOFTWARE
Activation Steps:
– Save the NPOS.lic (license file) into the root folder of a USB flash drive
– Insert the USB flash drive into the NanoPhotometer ®
– Select Preferences / CFR21
– Activate CFR21 toggle
Note: All existing network folders and server access entries will be deleted
by this step. – Add an Administrator account (see page 8 Add Account)
Note: It is necessary to add at least one Administrator account otherwise the
CFR21 Software is not activated.
Note: Please keep a copy of your Admin password for your records. For security
purposes, Admin passwords cannot be recovered. Should you lose your Admin
login details, you will need to contact the Implen Support team
(support@implen.de) for assistance with password
reset.
DEACTIVATION CFR21 SOFTWARE
For deactivation of the CFR21 Software deactivate the CFR21 toggle switch in
Preferences/CFR21. This step will perform a factory reset of the
NanoPhotometer ®. Save all data before deactivation of the CFR21 Software and
perform a factory reset.
Note: Deactivating the CFR21 Software requires a factory reset of the
NanoPhotometer ®. All data, user accounts, permissions, and settings will be
lost. Save all necessary data in advance.
SETTINGS
The CFR21 settings menu includes Four Eye Administrator, Secure Password, and Password Expiry.
FOUR EYE AUTHENTICATION
Four Eye Authentication requires confirmation from a second Administrator
account when implementing critical software changes. To enable the Four Eye
Administrator setting, activate the Four Eye Administrator toggle switch. It
is necessary to create at least two Administrator accounts for this setting.
The following features, settings, and actions require a confirmation from a second Administrator account if four eye authentication is active: Factory reset, change of date and time, deactivation of CFR21 software, deactivation of Four Eye Administrator, secure password, password expiry, rename, delete, move the folder, and delete the result file.
SECURE PASSWORD
Secure password is set by default and can be switched off.
Secure password ON:
At least 8 characters with a minimum of 1 special character, 1 capital letter,
1 lowercase letter, and 1 number.
Secure password OFF:
At least 4 characters/numbers and no further restrictions.
PASSWORD EXPIRY
Password expiry offers the possibility to have each user prompted to change
the account password on a regular basis. When password expiry is active it is
possible to enter a timeframe between 1 and 365 days. Default setting is 90
days.
Note: If the amount of days before passwords expire is reduced, it is possible that all passwords expire immediately and must be changed with the next login.
SETTING UP USER ACCOUNTS
There are three types of user accounts: Administrator, Power User, and User.
An Administrator has full access rights and can create Groups, Administrator,
Power User, and User accounts. Power Users and Users need to be assigned to a
group. A Power User can create User accounts in their defined group.
To add an Administrator, Group, Power User, or User select the desired
account/group category and push the + icon.
Note: If the account/group category or + icon is not available, the logged-in user does not have access rights to create the account or group.
ADD ACCOUNT
It is possible to add several Admin, Power User, and User accounts. Power User
and User accounts need to be assigned to a group.
Note: Please keep a copy of your Admin password for your records. For
security purposes, Admin passwords cannot be recovered. Should you lose your
Admin login details, you will need to contact the Implen Support team
(support@implen.de) for assistance with password
reset. Power User and User passwords can be recovered by an administrator.
-
Select category: Admin, Power User, or User
Note: In order to add a Power User or User create at least one Group. -
For Power, User / User account select a Group
-
Enter the user’s first and last name
-
Enter Login Name
Note: Allowed characters are: letters, digits, underscores, and dashes. Login name needs to start with a letter. Do not use the blank characters.
Note: Login names must be unique. It is not possible to use identical login names and/or group names. -
Set Login Password and confirm the password. This password is a temporary password that the user will be prompted to change after the first login.
Note: Secure passwords need to have at least 4 characters/numbers, but if the secure password is enabled at least 8 characters are required with a minimum of 1 special character, 1 capital letter, 1 lowercase letter, and 1 number.
-
Save User account by pushing the icon
Note: It is not possible to delete or change user accounts.
ADD NETWORK FOLDER
Network folders can only be created by the logged-in user for their own user
account. To create a network folder and select Network Folder in the user
account preferences.
Enter the Network Path of the network folder using either //IP/share/path or
//server/share/path. If the local network requires authentication enter the
user name and password for Windows or MacOS logon and the domain if necessary.
Save the settings by pushing the icon. The network state changes to
“connected” if the network folder is created successfully.
Note: The NanoPhotometer ® needs to be connected via LAN or WLAN to the
local network.
Network folders can be deleted by pushing the icon.
The folder nickname is created automatically (Network_login name) and is shown
in all directories.
USER RIGHTS
The following table describes the different user rights of Administrator,
Power User, or User.
Note: If “Yes/4 Eye” is displayed in the administrator rights column,
confirmation by a second administrator is required when Four Eye
authentication is active (see page 6 Four Eye Authentication).
Action | Administrator | Power User | User |
---|---|---|---|
Report Problem | Yes | No | No |
Reset | Yes/4 Eye | No | No |
Update | Yes | No | No |
Date and Time | Yes/4 Eye | No | No |
Language | Yes | No | No |
Enable NanoVolume (C40) | Yes | No | No |
Add Dyes | Yes | Yes | No |
Dyes show toggle switch | Yes | No | No |
Delete Dyes/Change Dyes | No | No | No |
Change Warning Messages | Yes | No | No |
Change Network (Settings, WLAN) | Yes | No | No |
Change Printer (Network printer, Report Configuration) | Yes | No | No |
CFR21 Off | Yes/4 Eye | No | No |
Add Admin/Power User Account | Yes | No | No |
Add Group | Yes | No | No |
Add User Account | Yes | Yes | No |
Set temporary password for lost password or misentry of password | Yes | No | No |
4 Eye Administrator | Yes/4 Eye | No | No |
Secure Password | Yes/4 Eye | No | No |
Password Expiry | Yes/4 Eye | No | No |
Audit Trail | Yes | Yes read-only | No |
Audit Trail Search | Yes | Yes read-only | No |
Saving of Audit Trail | Yes | No | No |
Save parameter as Stored Method | Yes | Yes | No |
Change parameter in opened Stored Method | Yes | Yes | No |
Delete Stored Methods | Yes/4 Eye | No | No |
Rename Folder | Yes/4 Eye | No | No |
Delete Folder | No | No | No |
Move Folder | No | No | No |
Delete Result File | Yes/4 Eye | No | No |
Rename Result File | Yes | Yes | No |
Move Result File | No | No | No |
Delete Results | Yes | No | No |
Note: User rights cannot be changed.
Note: Only functions with restrictions are listed. NPOS functions not
listed in the table above are available for all user roles (administrator,
power user, and user).
LOGIN TO THE NPOS SOFTWARE
If the CFR21 software is enabled a login is necessary for any action.
To log in enter the Login Name and password and confirm with OK.
Note: If another user is logged in e.g. with a control device (computer)
it is not possible to login to the NanoPhotometer® directly unless the logged-
in user logs off or a forced log-off is requested with an Administrator
account.
AUTOMATIC LOG OFF
There is an automatic screen lock if the NanoPhotometer® is inactive for 10
minutes. The screen can only be unlocked by the logged-in user or with a
forced log-off by an administrator.
SCREEN LOCK
The screen can be locked in all methods by pushing the icon in the navigation
bar.
Note: A locked screen can only be unlocked by the logged-in user or with
a forced log-off by an Administrator.
LOG OFF
Log off is only possible on the home screen by pushing the icon.
ELECTRONIC SIGNATURE
The electronic signature is set by default and cannot be disabled. Saving
measurement data needs to be confirmed by the logged-in user (Electronic
Signature: Login Name and
Password).
All saved file reports include the author, User ID, User Name, and date and
time of the electronic signature. IDS and PDF files cannot be altered.
A second signature is shown as reading/Save/Print if an IDS file is opened and
data are printed or exported as an Excel/PDF file. The second signature is the
electronic signature of the logged-in user at the time of printing or data
export.
Implen NanoPhotometer®
Instrument Type
Version
Serial Number
Setftest passed
Autosave
File Name
Reason
User ID
User Name
eSign Date
eSign Time| NP80
NPOS 4.2 build 14756
M80945
2019-08-23; 13:17
No
Grippe A/bjones/Headerids
Author
bjones
Becky Jones
2019-08-23
13:25:16| Read/Save/Print
msmith
Mark Smith
2019-08-23
13:27:35
---|---|---
AUDIT TRAIL
The audit trail function is automatically activated with CFR21 software
activation. The audit trail records all actions and preference changes in an
audit log. There is no delete or reset option for the audit trail available.
Analyzing and viewing the audit trail is possible as a logged-in Administrator
or Power User by opening the CFR21 preferences:
The audit trail opens a table including the following information for each recorded action and preference change: ID, Date/Time, User ID, Category, Action, and Details. The entries are sorted by year. The year can be changed with the dropdown above the table.
SAVING OF AUDIT TRAIL
The audit trail can be saved as a PDF or Excel file (Administrator only). The
selected year is saved. It is not possible to save the complete audit trail.
Note: To save audit trails for a defined time period, use the Audit Trail
Search function.
Note: A maximum of 50,000 entries can be saved in one file.
Saved audit trail files are always saved in the Audit Trail folder. It is
possible to select an additional folder location by selecting Additional to
The audit trail folder can only be accessed by Administrators via file server
access.
Note: Power user has only read permissions and cannot save the audit
trail.
AUDIT TRAIL SEARCH
The audit trail search function provides the option to search in the audit
trail by time period, category (administrator, power user, user), login name
action, or details.
To open the audit trail search function press the magnifier icon on the top
right in the audit trail.
It is possible to search for a time period (Timeframe) and additional search
options.
Once all search parameters are selected, press the search button to start the
search. The search result will be displayed as a table.
TIMEFRAME
Either all entries or the date range needs to be selected.
Selection of:
All entries: search is done in all audit trail entries. If no further search
option is selected the complete audit trail is shown.
Date Range: option to enter a start and end date to limit the search period.
Date can be entered by keyboard or time picker. Date needs to be entered in
the following format: yyyy-mm-dd (year-month-day).
ADDITIONAL SEARCH OPTIONS
There are four additional search options available: Category, login name,
action, and details.
Category: At least one category needs to be selected.
Login name: Dropdown shows all available login names depending on category
selection
Action: Free text field to search in the action table column of the audit
trail.
Details: Free text field to search in the details table column of the audit
trail.
AUDIT TRAIL SEARCH RESULT
The audit trail search result is shown in table format:
Year dropdown is only shown if the search result contains more than 1000
entries.
SAVING AUDIT TRAIL SEARCH RESULTS
The audit trail search result can be saved as a PDF or Excel file
(Administrator only). The complete search result is saved independently of the
year dropdown selection. A maximum of 50,000 entries can be saved in one file.
Note: Change search parameter/time period of search if search result has
more than 50,000 entries.
Audit trail files are always saved in the Audit Trail folder. It is possible
to select an additional folder location by selecting Additional to
The audit trail folder can only be accessed by Administrators via file server
access.
Note: Power user has only read permissions and cannot save the audit
trail.
PASSWORD LOSS/MISENTRY
If a Power User or User has lost the login password or entered it three times
wrong, a The administrator can change the password of the Power User/User in
the account settings (Preferences) to a temporary password. The Power User or
User will be prompted to change the temporary password after the first login.
Administrator passwords cannot be recovered if an administrator has lost the
password please contact the Implen support team
(support@implen.de).
VERSION HISTORY
Version | Date | Changes |
---|---|---|
1.0 | August 2019 | Initial Release |
1.1 | May 2020 | Change of firmware version number in CFR21 Software Statement |
1.2 | March 2021 | – Change of firmware version number in CFR21 Software |
Statement
– Power Users can read audit trails
– Note/warning message added that administrator passwords cannot be recovered.
Implen support is necessary.
2.0| Januar 2022| – Saving of Audit Trail (Excel and folder selection)
– Audit Trail Search
– User rights updated (Audit Trail Search)
APPENDIX
CFR21 SOFTWARE STATEMENT
Paragraph | Summary | Features |
---|
11.10 Controls for closed systems
11.10 Persons who use closed systems to create, modify, maintain, or transmit
electronic records shall employ procedures and controls designed to ensure the
authenticity, integrity, and, when appropriate, the confidentiality of
electronic records, and to ensure that the signer cannot readily repudiate the
signed record as not genuine. Such procedures and controls shall include the
following| Controls for closed systems| The NanoPhotometer® Software NPOS
4.2.14756 and higher contains the optional CFR21 feature. Once this CFR21
feature is activated all these requirements are fulfilled.
(a) Validation of systems to ensure accuracy, reliability, consistent intended
performance, and the ability to discern invalid or altered records.| System
validation| The complete NanoPhotometer® Software NPOS 4.2.14756 and higher is
validated by Implant to ensure the accurate, reliable, and intended
performance of all the components of the NanoPhotometer® system. IQ/OQ
procedures for the proper function of the NanoPhotometer® instrument can be
put in place. The proprietary file format IDS is protected by hash codes and
encryption to allow the identification of altered files.
(b) The ability to generate accurate and complete copies of records in both
human-readable and electronic form suitable for inspection, review, and
copying by the agency. Persons should contact the agency if there are any
questions regarding the ability of| Record generation and copying| In addition
to the protected IDS files, all relevant measurement parameters and results
can be exported to PDF using the PDF/A standard as well as Excel file format.
the agency to perform such review and copying of the electronic records.| |
---|---|---
(c) Protection of records to enable their accurate and ready retrieval
throughout the records retention period.| Record protection| Every export is
accompanied by an IDS file, which is protected by hash codes and encryption to
allow the detection of tampering. At any time, PDF and Excel reports can be
regenerated from these IDS files. Security measures for the storage of these
reports lie within the responsibility of the operating company.
(d) Limiting system access to authorized individuals.| Access limitation|
Before any use of the system, every user is required to log in for system
access.
Each user has a defined role, including access privileges.
(e) Use of secure, computer-generated, time-stamped audit trails to
independently record the date and time of operator entries and actions that
create, modify, or delete electronic records. Record changes shall not obscure
previously recorded information. Such audit trail documentation shall be
retained for a period at least as long as required for the subject electronic
records and shall be available for agency review and copying.| Audit trails|
Time-stamped audit trails are recorded for actions performed on the instrument
by the user such as file storage, transfer activities, and preference changes.
The audit trails can be exported in PDF format. The creation and signature of
the report files also create an audit trail report entry. Reports cannot be
overwritten.
(f) Use of operational system checks to enforce permitted
sequencing of steps and events, as appropriate.
| Operational system checks| Not applicable.
(g) Use of authority checks to ensure that only authorized individuals can use
the system, electronically sign a record, access the operation or computer
system input or output device, alter a record, or perform the operation at
hand.| Authority checks| It is ensured that users have the proper authority to
carry out particular functions based on their roles and access privileges. It
is the responsibility of the operating company to ensure that each user name
can be traced to a real individual and to ensure the correct assignment of
roles.
(h) Use of device (e.g. terminal) checks to determine, as appropriate, the
validity of the source of data input or operational instruction.| Device/
terminal checks| Checks are applied to allow only valid information input in
respective files. All CSV and JSON input files are checked to ensure valid
content.
(i) Determination that persons who develop, maintain, or use electronic
record/electronic signature systems have the education, training, and
experience to perform their assigned tasks.| Training and user accountability|
Implement Software Development team is fully and continuously trained. Implen
provides NanoPhotometer® Software user training. The operating company is
responsible for training on their SOPs in regard to electronic records and
electronic signatures. Implen supports the installation of these SOPs in
relation to NanoPhotometer® Software.
(j) The establishment of, and adherence to, written policies that hold|
Policies| Responsibility of the operating company.
individuals accountable and responsible for actions initiated under their
electronic signatures, in order to deter record and signature falsification.|
|
---|---|---
(k) Use of appropriate controls over systems documentation including:
(1) Adequate controls over the distribution of, access to, and use of documentation for system operation and maintenance.
(2) Revision and change control procedures to maintain an audit trail that documents time-sequenced development and modification of systems documentation.
| System Document Control| A release-specific software manual is distributed together with the NanoPhotometer® Software.
NanoPhotometer® Software development is governed by a design and change control process that ensures the creation and tracking of relevant documents.
11.30 Controls for open systems.
Persons who use open systems to create, modify, maintain, or transmit
electronic records shall employ procedures and controls designed to ensure the
authenticity, integrity, and, as appropriate, the confidentiality of
electronic records from the point of their creation to the point of their
receipt. Such procedures and controls shall include those identified in 11.10,
as appropriate, and additional measures such as document encryption and use of
appropriate digital signature standards to ensure, as necessary under the
circumstances, record authenticity, integrity, and confidentiality.| | Not
applicable. The NanoPhotometer® operates as a closed system.
11.50 Signature manifestations.
(a) Signed electronic records shall contain information associated with the
signing that clearly indicates all of the following:
(1) The printed name of the signer;
(2) The date and time when the signature was executed; and
(3) The meaning (such as review, approval, responsibility, or authorship)
associated with the signature.| Signature manifestations| The user management
ensures that all user IDs are unique.
(1) The system verifies the user credentials before creating any report (the
user is required to re-enter his/her user ID and password). The protected IDS
file as well as PDF and Excel files contain the user ID and the full name of
the user.
(2) The date & time when the signature was executed is associated with the
signature.
(3) The signature for creating the initial reports including the protected
IDS file is indicated as “Author” as a reason for signature. The signature for
(re-)creating reports in PDF and Excel format is indicated as
“Read/Save/Print” as a reason for signature.
(b) The items identified in paragraphs| Signature in| User’s full name, date,
and time are
(a)(1), (a)(2), and (a)(3) of this section shall be subject to the same
controls as for electronic records and shall be included as part of any human-
readable form of the electronic record (such as electronic display or
printout).| electronic records and in human-readable form| included within the
IDS file, which is protected by hash codes and encryption. When generating the
human-readable PDF and Excel files, the electronic signature is displayed with
a user ID, user’s full name, date & time, and reason.
---|---|---
11.70 Signature/record linking.
Electronic signatures and handwritten signatures executed to electronic
records shall be linked to their respective electronic records to ensure that
the signatures cannot be excised, copied, or otherwise transferred to falsify
an electronic record by ordinary means.| Signature/ record linking| The
signature is integrated into the IDS file and can therefore not be excised,
transferred, or copied.
11.100 General requirements.
(a) Each electronic signature shall be unique to one individual and shall not
be reused by, or reassigned to, anyone else.| Uniqueness of electronic
signatures| The user management system ensures that all user IDs are unique.
Therefore, all electronic signatures are unique.
(b) Before an organization establishes, assigns, certifies, or otherwise
sanctions an individual’s electronic signature, or any element of such
electronic signature, the organization shall verify the identity of the
individual.| Verification of identity| It is the responsibility of the
operating company to ensure the identity of the individual at the time of
creating the individual’s user account.
(c) Persons using electronic signatures shall, prior to or at the time of
such use, certify to the agency that the electronic signatures in their
system, used on or after August 20, 1997, are intended to be the legally
binding equivalent of traditional handwritten signatures.
(1) The certification shall be submitted in paper form and signed with a
traditional handwritten signature, to the Office of Regional Operations
(HFC-100), 5600 Fishers Lane, Rockville, MD 20857.
(2) Persons using electronic signatures shall, upon agency request, provide
additional certification or testimony that a specific electronic signature is
the legally binding equivalent of the signer’s handwritten signature.|
Certification| Responsibility of the operating company.
11.200 Electronic signature components and controls.
(a) Electronic signatures that are not based upon biometrics shall:
(1) Employ at least two distinct identification components such as an|
Controls for electronic signatures| Users are requested to enter user ID and
password for every signature action. In order to have access to a signature
action, the user must have a user ID in the user
identification code and password.| | management system and must be logged in
with user ID and password.
---|---|---
(i) When an individual executes a series of signings during a single,
continuous period of controlled system access, the first signing shall be
executed using all electronic signature components; subsequent signings shall
be executed using at least one electronic signature component that is only
executable by, and designed to be used only by, the individual.| |
(ii) When an individual executes one or more signings not performed during a
single, continuous period of controlled system access, each signing shall be
executed using all of the electronic signature components.
(2) Be used only by their genuine owners; and
(3) Be administered and executed to ensure that attempted use of an
individual’s electronic signature by anyone other than its genuine owner
requires the collaboration of two or more individuals.| |
(b) Electronic signatures based upon biometrics shall be designed to ensure
that they cannot be used by anyone other than their genuine owners.| | Not
applicable.
11.300 Controls for identification codes/passwords.
Persons who use electronic signatures based upon the use of identification
codes in combination with passwords shall employ controls to ensure their
security and integrity. Such controls shall include:| |
(a) Maintaining the uniqueness of each combined identification code and
password, such that no two individuals have the same combination of
identification code and password.| The uniqueness of ID/ password| The user
management system ensures unique user IDs.
(b) Ensuring that identification code and password issuances are periodically
checked, recalled, or revised (e.g., to cover such events as password aging).|
Password aging| The user management system provides password expiration and
account locking after several authentication failures.
Criteria can be set individually by the operating company.
(c) Following loss management procedures to electronically deauthorize lost,
stolen, missing, or otherwise potentially compromised tokens, cards, and other
devices that bear or generate identification codes or| Lost ID/ password
management| The user management system allows an administrator to assign a new
temporary password in case of lost, stolen, or missing passwords. Proper loss
management procedures are the responsibility of the operating company.
password information, and to issue temporary or permanent replacements using
suitable, rigorous controls.| |
---|---|---
(d) Use of transaction safeguards to prevent unauthorized use of passwords
and/or identification codes, and to detect and report in an immediate and
urgent manner any attempts at their unauthorized use to the system security
unit, and, as appropriate, to organizational management.| Controls to prevent
unauthorized credential use| NPOS with the activated CFR21 feature will lock
the screen after an inactive period of time to prevent unauthorized attempted
use. Other transaction safeguards such as supervision of blocked accounts etc.
lies within the responsibility of the operating company.
(e) Initial and periodic testing of devices, such as tokens or cards, that
bear or generate identification code or password information to ensure that
they function properly and have not been altered in an unauthorized manner.|
Periodic testing of ID/ password generation| Responsibility of the operating
company.
Important Notice: In accordance with FDA regulation, a vendor cannot claim that its software products are certified 21 CFR Part 11 compliant. A vendor, instead, can provide all Technical Controls for 21 CFR Part 11 compliance built into their product. As such Implant does not, at any time, imply that the use of any Implant CFR21 product will automatically give the customer protection to and therefore compliance with 21 CFR Part 11. It is the responsibility of the user to implement the Procedural and Administrative Controls (both correctly and consistently) along with using products with the correct Technical Controls for overall Part 11 compliance. All CFR21 systems must therefore be independently audited.
DISCLAIMER
THE WARRANTIES SET FORTH IN THE NANOPHOTOMETER MANUAL, ABOVE, ARE IN LIEU OF, AND THIS AGREEMENT EXPRESSLY EXCLUDES, ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ORAL OR WRITTEN, INCLUDING, WITHOUT LIMITATION, (a) ANY WARRANTY THAT THE SOFTWARE IS ERROR-FREE, WILL OPERATE WITHOUT INTERRUPTION, OR IS COMPATIBLE WITH ALL EQUIPMENT AND SOFTWARE CONFIGURATIONS; (b) ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY; AND (c) ANY AND ALL WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.
LIMITATION OF LIABILITY
IN NO EVENT SHALL LICENSOR OR ITS OWN LICENSORS AND SUPPLIERS BE LIABLE FOR
ANY INDIRECT, PUNITIVE, INCIDENTAL, SPECIAL, OR CONSEQUENTIAL DAMAGES,
INCLUDING, WITHOUT LIMITATION, LOST PROFITS, ARISING OUT OF OR IN ANY WAY
CONNECTED WITH YOUR USE OF THE SOFTWARE OR ANY INFORMATION OR MATERIALS
AVAILABLE THROUGH THE SOFTWARE, WHETHER BASED IN CONTRACT, TORT, STRICT
LIABILITY OR OTHERWISE, EVEN IF LICENSOR HAS BEEN ADVISED OF THE POSSIBILITY
OF DAMAGES. IN ADDITION, THE LICENSOR
ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY CLAIMS THAT MAY RESULT DIRECTLY
OR INDIRECTLY FROM THE RESULTS YOU ACHIEVE USING THE SOFTWARE OR WHICH RELATE
TO THE STORAGE OF ANY DATA OR FOR THE DELIVERY, SECURITY, OR AVAILABILITY OF
ANY DATA. WITHOUT LIMITATION OF THE FOREGOING, TOTAL LIABILITY OF LICENSOR FOR
ANY REASON WHATSOEVER RELATED TO THE SOFTWARE, THE USE OR INABILITY TO USE THE
SOFTWARE, OR FOR ANY CLAIMS RELATING TO THIS EULA SHALL NOT EXCEED IN THE
AGGREGATE US$5,000.
ALPHABETICAL INDEX
A
Accounts
Administrator
Power User
User
Activation
Administrator
Audit Trail
Save
Audit Trail Search
Additional Search Options
Result
Save
Timeframe| 8
8
8
8
5
5, 8, 10
4, 13
13
14
15
15
15
14
---|---
C
CFR21 Software
Activation
Deactivation
CFR21 Software Statement
Compliance Information
D
Deactivation
Disclaimer
E
Electronic Signature
F
Four Eye Authentication
G
Group| 5
5
17
45
22
4, 12
6
8
---|---
L
Limitation of Liability
Log Off
Login
N
Network Folder
P
Password
Expiry
Loss
Missentry
Power User
S
Screen Lock
Secure Password
Setting up User Accounts
Settings
Accounts
Four Eye Authentication
Network Folder
Password Expiry
Secure Password
U
User
User Accounts
User Management
User Rights
V
Version History| 22
11
11
9
7
16
16
8, 10
11
6
7
6
8
6
9
7
6
8, 10
7
4
10
17
---|---
NanoPhotometer® CFR21 Software User Manual Version 2.1
Documents / Resources
|
IMPLEN CFR21 NanoPhotometer
Software
[pdf] User Manual
CFR21, NanoPhotometer Software, CFR21 NanoPhotometer Software
---|---
References
- U.S. Food and Drug Administration
- Best In UV-Vis Spectrophotometers | Implen NanoPhotometer
- Best In UV-Vis Spectrophotometers | Implen NanoPhotometer
- Best In UV-Vis Spectrophotometers | Implen NanoPhotometer
Read User Manual Online (PDF format)