GARO CV8-NPS Shower Boards Instruction Manual

June 5, 2024
GARO

SHOWER BOARDS: CV8-NPS

GARO CV8 NPS Shower Boards

Non-Priority Shower
Board CV8-NPS
Garo Shower Boards are designed to facilitate the use of two electric showers which are being supplied from a domestic 63A single-phase supply. Both showers may continually use <3kW of power each, however, when one exceeds this power use the Board will automatically cut the power to the second shower thus protecting the main supply fuse.

TECHNICAL DATA

• Degree of protection. IP40
• Resistance to impact. IK08
• Auto-extinguishing degree. HB (UL94)
• Test of resistance to glow wire. 650° C
• Ball pressure test. 70° C

According to the 2006/95/CE directive and EN 61439-1 and UNE-EN 61439-3 norms on affected parts.

NOTES:

BOTH SHOWERS MUST BE DRAWING OVER 3KW FOR THE LOAD RELAY TO OPERATE.
BOTH SHOWER NEUTRALS ARE TO BE CONNECTED TO THE MAIN NEUTRAL BAR
MAINS CABLE TO BE CONNECTED TO THE BOTTOM OF 40A RCBO

K1 – 40A 1/P CONTACTOR (SHOWER NO.1)

K2 – 40A 1/P CONTACTOR (SHOWER NO.2
K3 – CURRENT SENSING RELAY (SHOWER NO.1)
K4 – CURRENT SENSING RELAY (SHOWER NO.2)
****NOTE: UNITS MUST BE DRAWING AT LEAST 11-12 AMPS TO OPERATE

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>