BLACK BOX LGC5700A Gigabit ENET Poe++ Media Converter User Manual
- June 5, 2024
- BLACK BOX
Table of Contents
BLACK BOX LGC5700A Gigabit ENET Poe++ Media Converter
SPECIFICATIONS
IEEE
IEEE SPECIFICATION
Description| 802.3af PoE| 802.3at PoE+| 802.3.bt PoE++ Type 3
Power available at PD| 12.95 watts| 25.5 watts| 51 watts
Max power delivered by PSE| 15.4 watts| 30.0 watts| 60 watts
Voltage range at PSE| 44.0 to 57.0 VDC| 50.0 to 57.0 VDC| 50.0 to 57.0 VDC
Voltage range at PD| 37.0 to 57.0 VDC| 42.5 to 57.0 VDC| 42.5 to 57.0 VDC
LGC5600A MEDIA CONVERTER
Description| LGC5600A
Gigabit Media Converter with 802.3bt 60W, AC power, Commercial temperature range
---|---
Standard Compliances
| IEEE 802.3,
IEEE 802.3af (15.40 watts max), IEEE 802.3at (30 watts max), IEEE 802.3bt (60 watts max)
PoE++ Supported Modes| IEEE Alternate A (Alt A) and 4-Pair
Regulatory Compliances| UL, CE, FCC Class A, RoHS, WEEE, REACH
Frame Size| Up to 10,240 bytes
AC Power Requirements| 100 to 240 VAC/50 to 60 Hz
0.62 A at 120 VAC (typical)
Dimensions| 1.0″ H x 4.5″ W x 6.0″ D (2.5 x 11.4 x 15.2 cm)
Weight
| Module Only: 1.1 lb. (0.5 kg)
Module w/Adapter: 2.8 lb. (1.3 kg)
Operating Temperature
| Commercial: 32 to 122° F (0 to 50° C)
Storage: -40 to +176° F (-40 to +80° C)
Humidity| 5 to 95% (non-condensing)
Altitude| -328 to +13,123 ft. (-100 to +4,000 m)
MTBF (hours)| Module Only: 474,000
AC Adapter: 100,000
LGC5700A INDUSTRIAL MEDIA CONVERTER
Description| LGC5700A
Gigabit Media Converter with 802.3bt 60W, DC power, Industrial temperature range
---|---
Standard Compliances
| IEEE 802.3,
IEEE 802.3af (15.40 watts max), IEEE 802.3at (30 watts max), IEEE 802.3bt (60 watts max)
PoE++ Supported Modes| IEEE Alternate A (Alt A) and 4 Pair
Regulatory Compliances| UL, CE, FCC Class A, RoHS, WEEE, REACH
Frame Size| Up to 10,240 bytes
DC Power Requirements
| ±44 to ±57 VDC;
1.16 A at 56 VDC
3-pin terminal (isolated)
Dimensions| 1.0″ H x 4.5″ W x 6.0″ D (2.5 x 11.4 x 15.2 cm)
Weight| 1.1 lb. (0.5 kg)
Operating Temperature
| Industrial: -40 to +167° F (-40 to +75° C)
Storage: -40 to +176° F (-40 to +80° C)
Humidity| 5 to 95% (non-condensing)
Altitude| -328 to +13,123 ft. (-100 to +4,000 m)
MTBF (hours)| 474,000
OVERVIEW
INTRODUCTION
This User Manual describes the functions of the Gigabit 802.3bt PoE++ and the
Gigabit Industrial 802.3bt PoE++ media converters.
The LGC5600A and LGC5700A are media converters that convert 10/100/1000BASE-T
RJ-45 to 1000BASE-X or 100BASE-X fiber and support Power-over-Ethernet (60 W
PoE++).
Equipment that provides DC power over twisted-pair cable is called Power
Sourcing Equipment (PSE). Equipment that is powered over twisted-pair cable is
called a Powered Device (PD).
The LGC5600A and LGC5700A are PSE equipment supporting IEEE 802.3af PoE, IEEE
802.3at PoE+, and IEEE 802.3bt PoE++ 60 W on the RJ-45 port.
MEDIA CONVERTER DESCRIPTIONS
Model Number | Description |
---|
LGC5600A
| Gigabit Media Converter with (1) SFP and (1) 10/100/1000 RJ-45, External AC Adapter, 100-240 VAC, with U.S. Power Cord, Commercial Temperature: 32 to 122° F (0 to 50°C)
LGC5700A
| Gigabit Media Converter with (1) SFP and (1) 10/100/1000 RJ-45, Direct DC input, with 3-pin DC Terminal Connector,
Industrial Temperature -40 to 167° F (-40 to 75°C)
COMPATIBLE FIBER SFPS
PART NUMBER| DESCRIPTION| DISTANCE
100-MBPS CONNECTIONS| |
LFP401| SFP, 155-Mbps, Extreme Temperature, 850 nm Multimode Fiber, 2
km, LC| 2 km
LFP402| SFP, 155-Mbps, Extreme Temperature, 1310 nm Multimode Fiber, 2
km, LC| 2 km
LFP403| SFP, 155-Mbps, Extreme Temperature, 1310 nm Singlemode Fiber, 30
km, LC| 30 km
1000-MBPS CONNECTIONS| |
LFP411| SFP, 1.25-Gbps, Extreme Temperature, 850 nm Multimode Fiber, 550
m, LC| 550 m
LPF412| SFP, 1.25-Gbps, Extreme Temperature, 1310 nm Multimode Fiber, 2
km, LC| 2 km
LFP413| SFP, 1.25-Gbps, Extreme Temperature, 1310 nm Singlemode Fiber,
10 km, LC| 10 km
LFP414| SFP, 1.25-Gbps, Extreme Temperature, 1310 nm Singlemode Fiber,
40 km, LC| 40 km
LFP420| SFP, 1.25-Gbps, Extreme Temperature, 1550/1310 nm Singlemode
Simplex Fiber, 10 km, LC| 10 km
LFP421| SFP, 1.25-Gbps, Extreme Temperature, 1310/1550 nm Singlemode
Simplex Fiber, 10 km, LC| 10 km
LFP441| SFP, 1.25-Gbps, 850nm Multimode Fiber, 550 m, LC| 550 m
LFP442| SFP, 1.25-Gbps, 1310nm Singlemode Fiber, 20 km, LC| 20 km
NOTES:
- All Black Box SFPs feature Extended Diagnostics (excluding LFP441 and LFP442).
- Black Box Media Converters also support generic SFPs.
INSTALLATION PROCEDURE OVERVIEW
- Configure DIP switches
- Apply Power
- Connect Cables
- Verify Operation
INSTALLATION
STEP 1: CONFIGURE DIP SWITCHES
DIP switches are located on the side of the module. The DIP switches are used to configure ports, link modes, and PoE++/PSE options.
The table below provides a description of each DIP switch position and function.
DIP SWITCH DEFINITIONS
Switch | DOWN | UP | Function |
---|---|---|---|
1 | Auto | 100 | SFP Port Fiber Speed |
2 | N/A | N/A | N/A |
3 | AN | MAN | RJ-45 Port Auto/Manual |
4 | 100 | 10 | RJ-45 Port Speed (Only in MAN mode) |
5 | FDX | HDX | RJ-45 Port Duplex (Only in MAN mode) |
6 | Off | On | Pause Capability |
7 | On | Off | RJ-45 Port PSE Power |
8 | N/A | N/A | N/A |
9 | Norm | Force | RJ-45 Port PSE Power Override |
10 | N/A | N/A | N/A |
11 | N/A | N/A | N/A |
12 | See DIP switch Description | Link Mode Selection | |
13 | Link Mode Selection | ||
14 | Off | P1 Lk Loss | PSE Reset |
15 | N/A | N/A | N/A |
16 | N/A | N/A | N/A |
SW1 – Fiber Speed: Auto/100
This DIP switch configures the speed of the transceiver installed in the SFP
receptacle. If this DIP switch is in the DOWN “Auto”
(default) position, the port will automatically detect the data rate of the
transceiver installed and operate at 100 Mbps or 1000 Mbps accordingly.
If the automatic detection fails to detect the speed of the installed SFP,
then the speed will be set to 1000 Mbps.
If this DIP switch is in the UP “100” position, a 100 Mbps capable transceiver
must be installed in the SFP receptacle.
When an RJ-45 transceiver is installed in a SFP receptacle, setting this DIP
switch to UP “100” position enables the port to operate at 100 Mbps.
SW2 – Reserved
This DIP switch must be left in the DOWN (default) position.
SW3, SW4 and SW5 – RJ-45 Configuration
RJ-45 PORT CONFIGURATION MATRIX
SW3 RJ-45
AN/Man
| SW4 RJ-45 100/10| SW5 RJ-45
FDX/HDX
| ****
RJ-45 Mode of Operation
---|---|---|---
AN (DOWN)| 10 or 100 (N/A)| FDX or HDX (N/A)| The RJ-45 port is set to auto-
negotiation with the following modes advertised: 1000FDX, 1000HDX, 100FDX,
100HDX, 10FDX, 10HDX
MAN (UP)| 100 (DOWN)| FDX (DOWN)| The RJ-45 port is set to manual negotiation
and is forced to 100FDX
MAN (UP)| 100 (DOWN)| HDX (UP)| The RJ-45 port is set to manual negotiation
and is forced to 100HDX
MAN (UP)| 10 (UP)| FDX (DOWN)| The RJ-45 port is set to manual negotiation and
is forced to 10FDX
MAN (UP)| 10 (UP)| HDX (UP)| The RJ-45 port is set to manual negotiation and
is forced to 10HDX
SW6 – Pause: Off/On
In auto-negotiation mode, setting this DIP switch to the UP “On” position
allows the module to advertise Symmetrical and Asymmetrical Pause capability.
In auto-negotiation mode, setting the DIP switch to the DOWN “Off” (default)
position allows the module to advertise no Pause capability. In the manual
mode, this DIP switch determines the Pause behavior.
SW7 – Power Sourcing Function: On/Off
The RJ-45 port automatically detects the attached PD and provides the PD with
the necessary power.
This DIP switch controls the power sourcing function for the RJ-45 port. When
this DIP switch in the DOWN “On” (default) position, the power sourcing
function is enabled. When the DIP switch is in the UP “Off” position, the
power sourcing function is disabled.
SW8 – Reserved
This DIP switch must be left in the DOWN (default) position.
SW9 – PSE Power Override: Norm/Force
This DIP switch allows the PoE++ power to be forced ON when connected to a PD
with non-standard detection characteristics.
When this DIP switch is in the DOWN “Norm” (default) position, the RJ-45 port
will automatically perform the detection, classification, and powering
functions for the attached PD. When this DIP switch is in the UP “Force”
position, a maximum of 60 watts of power will be available to the PD.
SW10 and SW11 – Reserved
These DIP switches must be left in the DOWN (default) position.
SW12 and SW13 – Link Modes
The LGC5600A and LGC5700A feature Link Segment and Asymmetrical Link Propagate
fault detection modes.
Link Segment
In Link Segment mode, all ports operate independently. A loss of a receive
link signal will only affect the port detecting the loss
of signal. The other port will continue to generate a link signal. A loss of
link on the RJ-45 port will only affect the RJ-45 port,
and the fiber port will remain unaffected.
Asymmetrical Link Propagate
In Asymmetrical Link Propagate mode, faults are propagated based on the port
notation. Port 1 (fiber) to Port 2 (RJ-45) notation indicates the direction
the loss of link signal will propagate. A loss of receive link on the Fiber
Port 1 causes the RJ-45 Port 2
to drop its link due to the propagated state (Port 1 to Port 2). The loss of
link on the RJ-45 Port 2 does not cause the loss of link
to propagate. The loss only propagates in the Port 1 to Port 2 direction.
NOTE: A loss of link or loss of signal is when the optical receiver on the
media converter can no longer detect the presence
of an optic signal.
LINK MODES
SW12 | SW13 | Function |
---|---|---|
DOWN | DOWN | Link Segment (LS) |
UP | DOWN | Asymmetrical Link Propagate Port 1 (fiber) to Port 2 (RJ-45) |
DOWN | UP | Asymmetrical Link Propagate Port 2 (RJ-45) to Port 1 (fiber) |
UP | UP | Invalid Configuration |
SW14 – PSE Reset: Off/P1 Lk Loss
The module can be configured to reset the PoE++ output power for 2 seconds
after a loss of receive link on the fiber port. This feature is typically used
to allow a PD to re-initialize after a failure on the incoming fiber.
When this DIP switch is in the UP “P1 Lk Loss” position, the module will
disable PoE++ output power for 2 seconds following a loss of receive link on
the fiber port. When this DIP switch is in the DOWN “Off” (default) position,
PoE++ output power does not reset
on a fiber loss.
SW15 and SW16 – Reserved
This DIP switch must be left in the DOWN (default) position.
STEP 2: APPLY POWER
AC Power for LGC5600A
To power the module using the AC/DC adapter, connect the DC plug at the end of
the wire on the AC/DC adapter to the DC connector on the module. Then connect
the AC/DC adapter to the AC outlet. Confirm that the module has powered up
properly by checking
the Power LED located on the front of the module.
Installation of the equipment should be such that the air flow in the front,
back, side and top vents of the chassis are not compromised or restricted.
Secure the grounding wire to the ground screw. See the figure below for the
location of the grounding screw.
WARNING!!!
NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE POWER SUPPLY. OPENING THE
CHASSIS MAY CAUSE SERIOUS INJURYOR DEATH. THERE ARE NO USER REPLACEABLE OR
SERVICEABLE PARTS IN THIS UNIT.
DC Power for LGC5700A
A power source should be available within 5 ft. (1.5-m) of the module. The
over-current protection for connection with centralized DC shall be provided
in the building installation, and shall be a UL listed circuit breaker rated
20 Amps, and installed per the National Electrical Code, ANSI/NFPA-70.
The LGC5700A requires 50 to 57 VDC @ 1.16 Amp max rated power (see
specification table). Appropriate overloading protection should be provided on
the DC power source outlets used.
WARNING: OnlyaDC power source that complies with safety extra low voltage (SELV) requirements can be connected to the DC-input power supply.
WARNING REGARDING EARTHING GROUND:
- This equipment shall be connected to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode is connected.
- This equipment shall be located in the same immediate area (such as adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor, and also the point of earthing of the DC system. The DC system shall not be earthed elsewhere.
- The DC supply source is to be located within the same premises as this equipment.
- There shall be no switching or disconnecting devices in the earthed circuit conductor between the DC source and the earthing electrode conductor.
Locate the DC circuit breaker of the external power source, and switch the
circuit breaker to the OFF position.
Prepare a power cable using a three conductor insulated wire (not supplied)
with 12 AWG to 14 AWG thickness. Cut the power cable to the length required.
Strip approximately 3/8 of an inch of insulation from the power cable wires.
Connect the power cables to the terminal by fastening the stripped ends to the
DC power connector.
WARNING: Note the wire colors used in making the positive, negative, and
ground connections. Use the same color assignment for the connection at the
circuit breaker.
Secure the grounding wire to the ground screw. See the figure below for the
location of the grounding screw.
Connect the power wires to the circuit breaker and switch the circuit breaker ON. If any modules are installed, the Power LED should indicate the presence of power. Installation of the equipment should be such that the air flow in the front, back, side, and top vents of the chassis are not compromised or restricted
WARNING!!!
NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE POWER SUPPLY. OPENING THE
CHASSIS MAY CAUSE SERIOUS INJURYOR DEATH. THERE ARE NO USER REPLACEABLE OR
SERVICEABLE PARTS IN THIS UNIT.
STEP 3: CONNECT CABLES
-
Insert the SFP transceiver into the SFP receptacle on the front of the module.
NOTE: The release latch of the SFP Fiber transceiver must be in the closed (up) position before insertion. -
Connect an appropriate multimode or singlemode fiber cable to the SFP on the front of the module. It is important to ensure
that the transmit (TX) is attached to the receive side of the module at the other end and the receive (RX) is attached to the transmit side. When using a single-fiber (SF) SFP, the TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end. -
Connect the Ethernet 10/100/1000 RJ-45 port via a Category 5 or better cable to an external 10BASE-T, 100BASE-TX,
or 1000BASE-T Ethernet PD device.
STEP 4: VERIFY OPERATION
Once the module has been installed and configured per steps 1 through 4,
verify the module is operational by viewing the LED indicators.
The Power LED indicates the module is receiving power.
The Fiber Optic LEDs indicates the fiber optic connection has been
established.
The RJ-45 10/100/1000 LEDs indicate the speed of the RJ-45 port connection.
The PSE LED indicates the module has established a successful detection of a
PD and is supplying Power over Ethernet.
POWER LED INDICATORS
Legend| Indicator| Description
Pwr
| OFF| Unit not powered
Green – ON| Unit powered
Amber – ON| Over temperature condition
FIBER PORT LED INDICATORS
Legend| Indicator| Description
100
| OFF| No link
Green – ON| Port linked at 100 Mbps
Green – Blinking at 10 Hz| Port data activity at 100 Mbps
Green – Blinking at 1 Hz| Port linked at 100 Mbps and in redundant standby
mode
Amber – Blinking at 1 Hz| Port linked at 100 Mbps and receiving Far End Fault
Indicator (FEFI)
1000
| OFF| No link
Green – ON| Port linked at 1000 Mbps
Green – Blinking at 10 Hz| Port data activity at 1000 Mbps
Green – Blinking at 1 Hz| Port linked at 1000 Mbps and in redundant standby
mode
Amber – Blinking at 1 Hz| Port linked at 1000 Mbps and receiving AN Remote
Fault
10
(100+1000)
| OFF| No link
Green – ON| Port linked at 10 Mbps
Green – Blinking at 10 Hz| Port data activity at 10 Mbps
Green – Blinking at 1 Hz| Port linked at 10 Mbps and in redundant standby mode
Stat
| OFF| Transceiver does not support digital diagnostics or no transceiver
(SFP) is installed
Green – ON| Transceiver (SFP) supports digital diagnostics and no alarm is
detected
Amber – ON| Transceiver (SFP) supports digital diagnostics and alarms are
present
RJ-45 PORT INDICATORS
Legend| Indicator| Description
100
| OFF| No link
Green – ON| Port linked at 100 Mbps
Green – Blinking at 10 Hz| Port data activity at 100 Mbps
1000
| OFF| No link
Green – ON| Port linked at 1000 Mbps
Green – Blinking at 10 Hz| Port data activity at 1000 Mbps
10
(100+1000)
| OFF| No link
Green – ON| Port linked at 10 Mbps
Green – Blinking at 10 Hz| Port data activity at 10 Mbps
Amber – Blinking at 1 Hz| Port linked at 10 Mbps and receiving AN Remote Fault
FDX
| Green – ON| Port is configured for full-duplex via DIP switch or has
negotiated to full-duplex in AN mode
OFF| Port is configured for half-duplex via DIP switches or Port 2 has
negotiated to half-duplex in AN mode or Port 2 in AN mode has not established
the correct connection
PSE
| Green – ON| Port PSE is active
Amber – ON| Port PSE inactive
OFF| Port PSE disabled
REGULATORY INFORMATION
FCC STATEMENT
This equipment generates, uses, and can radiate radio-frequency energy, and if
not installed and used properly, that is, in strict accordance with the
manufacturer’s instructions, may cause interference to radio communication. It
has been tested and found to comply with the limits for a Class A computing
device in accordance with the specifications in Subpart B of Part 15 of FCC
rules, which are designed to provide reasonable protection against such
interference when the equipment is operated in a commercial environment.
Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to
take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise
emission from digital apparatus set out in the Radio Interference Regulation
of Industry Canada.
DISCLAIMER
Black Box Corporation shall not be liable for damages of any kind, including, but not limited to, punitive, consequential or cost of cover damages, resulting from any errors in the product information or specifications set forth in this document and Black Box Corporation may revise this document at any time without notice.
TRADEMARKS USED IN THIS MANUAL
Black Box and the Black Box logo type and mark are registered trademarks of
Black Box Corporation.
Any other trademarks mentioned in this manual are acknowledged to be the
property of the trademark owners.