KARCHER SP 7 Dirt Inox Mit Level Sensor und integriertem Vorfilter Instruction Manual

June 5, 2024
Karcher

SP 7 Dirt Inox
Operating Instructions
Please read the operating instructions carefully before using the unit.

KARCHER SP 7 Dirt Inox Mit Level Sensor und integriertem
Vorfilter

Register and Win!
www.kaercher.com/register-and-win


59665390 10/15

KARCHER SP 7 Dirt Inox Mit Level Sensor und integriertem Vorfilter - Fig
1

**** Please read and comply with these original instructions prior to the initial operation of your appliance and store them for later use or subsequent owners.

Safety instructions for immersion pumps

  • Please read the operating instructions for your machine before using it, and pay particular attention to the following safety instructions.
  • Warning and information plates on the machine provide important directions for safe operation.
  • Apart from the notes contained herein the general safety provisions and rules for the prevention of accidents of the legislator must be observed.
  • Keep packaging films away from children, there is a risk of suffocation!

Hazard levels
DANGER
Pointer to immediate danger, which leads to severe injuries or death.
WARNING
Pointer to a possibly dangerous situation, which can lead to severe injuries or death.
**CAUTION
Pointer to a possibly dangerous situation, which can lead to minor injuries.
ATTENTION**
Pointer to a possibly dangerous situation, which can lead to property damage.

Electric components
DANGER
Risk of electric shock.

  • Check the power cord with the main plug for damage before every use. If the power cord is damaged, please ar- range immediately for the exchange by authorized customer service or a skilled electrician.
  • Install all electrical plug connections in a flood-proof area.
  • Unsuitable electrical extension cables can be hazardous. Only use electrical ex- tension cables that have been approved and labeled for this purpose and have an adequate cable cross-section outdoors.
  • The main plug and the coupling of an extension cable must be watertight and must never lie in water. Moreover, the coupling may never lie on the ground. The use of cable reels that ensure that the sockets are at least 60 mm above the ground is recommended.
  • Do not use the power cord to carry/ transport the machine.
  • To separate the machine from the mains, pull the plug and not the power cord.
  • Do not scrape the power cord across sharp edges and ensure that it does not get pressed.
  • The voltage indicated on the type plate must correspond to the voltage of the electrical source.
  • To avoid risks, all repairs and replacement of spare parts may only be carried out by the authorized customer service personnel.
  • Operate pumps only on sockets that are equipped with a fault current protection switch with a nominal fault current of max. 30 mA and a protective earth contact (earthing).
  • Check the fault current protection switch and the protective earth contact (earthing) for proper function at regular intervals.
  • Never operate the pumps while there are persons in the pool or garden pond.
  • In Austria pumps to be used in swimming pools and garden ponds should be equipped with a fixed connection line according to ÖVE B/ EN 60555 Part 1 to 3; the power supply should be via an ÖVEtested isolating transformer whereby the second nominal voltage should not exceed 230V.
  • The electrical connection of the system may only be performed by a qualified electrician. Please follow the respective national regulations!

Safe handling
WARNING

  • This appliance is not intended for use by persons with limited physical, sensory or mental capacities or lacking experience and/or skills unless such persons are accompanied and supervised by a person in charge of their safety or they have received precise instructions on the use of this appliance and have understood the resulting risks.
  • Children may only use this appliance if they are over the age of 8 and supervised by a person in charge of their safety, or if they have received instructions on the use of this appliance and have understood the resulting risks.
  • Children must not play with this appliance.
  • Supervise children to prevent them from playing with the appliance.
  • Cleaning and user maintenance must not be performed by children without supervision.
  • Turn off the appliance and remove the mains plug prior to any care and maintenance works.

CAUTION

  • Create stability for the appliance prior to any work on or with the appliance to prevent accidents or damage.
  • In order to prevent accidents or injuries, mind the weight of the appliance during transport (see technical data).
  • In order to prevent accidents or injuries, mind the weight of the appliance when choosing the storage location (see technical data).

Other risks
DANGER
Danger of explosion

  • Do not pump corrosive, highly combustible, or explosive fluids (e.g. petroleum, petrol, acids, or nitro thinner).

  • Do not operate the device in fire or explosion-endangered surroundings.
    CAUTION

  • Water that has been delivered with this appliance is no drinking water!

ATTENTION
This can cause damage to the appliance.

  • Do not pump greases, oils, and saltwater.
  • Do not pump wastewater from sanitary facilities and silty water with a lower flowability than clear water.
  • Do not pump water that has a higher temperature than 35°C.

Warranty

The warranty terms published by the relevant sales company are applicable in each country. We will repair potential failures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or defects in manufacturing. In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service center. Please submit the proof of purchase. The adhesive type label must not be removed from the device. Warranty is no longer granted if the label is removed.

Environmental protection

The packaging material can be recycled.
Please do not place the packaging into the ordinary refuse for disposal, but arrange for the proper recycling.
Old appliances contain valuable materials that can be recycled. Please arrange for the proper recycling of old appliances. Please dispose of your old appliances using appropriate collection systems.

Notes about the ingredients (REACH)
You will find current information about the ingredients at: www.kaercher.com/REACH

Description of the Appliance

  1. Switch (automatic mode / manual operation)
  2. Carrying handle
  3. Power cord with plug
  4. Rail (level sensor)
  5. Level sensor
  6. Automatic venting device
  7. Quick-Connect
  8. Pump connecting piece (1“, 1¼“ and 1½“ hose connection and G1½ – thread)
  9. Connection nozzle (G1½ – thread)
  10. Pre-filter

Proper use

This appliance has been designed for use in private households and is not intended for commercial use. The manufacturer is not responsible for any damages that may occur on account of improper use or wrong operations.
The device is mainly intended for draining building parts in case of flooding, but also for pumping over or out containers, for water removal from wells and shafts as well as for draining water from boats and yachts, provided that it is freshwater.
NOTICE
The device is not suitable for continuous pump operation (e.g. continuous circulation in a pond) or as a stationary installation (e.g. lifting device, fountain pump).

Approved feed fluids
  • Freshwater up to a certain degree of soiling
  • Water from the swimming pool (provided the dosing of additives is proper)
  • Washing lye
  • Water with a degree of contamination up to a grain size of 30 mm

DANGER
Risk of injury, risk of damage! Caustic, slightly inflammable, and other explosive substances (such as petrol, petroleum, diluted nitrogen), greases, oils, saltwater, and wastewater from toilets as well as sludgy water that has a slower flow capacity than water, must not be transported with this pump. The temperature of the delivered fluid must be between 5 °C and 35°C.

Startup

NOTICE
The shorter the hose length and the larger the hose diameter, the higher the pump capacity.
To prevent clogging of the pump, slide down the prefilter with hose diameters of less than 1¼ “.
The pump connection is equipped with a plug system (Quick-Connect).
The unmounted connection nozzle with the pump connecting piece is enclosed in the device.
Illustration A

  • To remove the connection nozzle, press the QuickConnect (grey button).
    Illustration B

  • Screw the pump connecting piece onto the connection nozzle.

  • Slide the hose clamp onto the hose.

  • Slide the hose onto the pump connecting piece and secure it by means of a hose clamp.

  • Slide the connection nozzle into the Quick-Connect.

NOTICE
Hoses with a diameter of 1“, 1¼“, and 1½“ can be connected to the pump connecting piece.
To increase the flow volume, the pump connecting piece can be shortened according to the hose used.
Illustration

NOTICE
The suction area must not be blocked by soil.
In case of muddy ground, place the pump on a brick or the like.
Ensure that the pump is level.
Do not carry the pump on the cable or the hose.

Operation

DANGER
Risk of mortal danger on account of electric shock!
Do not touch feed fluids, the rope attached to the carrying handle as well as objects that are in contact with the feed fluid (e.g. pipelines extending into the water, railings, etc.).

General

Illustration E
NOTICE
The fluid level must be at least 50 mm for the pump to draw independently.
The pump can pump up to a residual fluid height of 35 mm.

Automatic venting device

Illustration D
With a low fluid level, possibly drawn air or air that is present in the pump escapes via the automatic venting device. In addition, fluid may leak at this spot.
If the pump has suction problems with a low fluid level, unplug and plug in the mains plug repeatedly in order to support the suction process.

Automatic operation

Illustration E
NOTICE
In the automatic mode, the level sensor automatically controls the pumping operations.
As soon as the level sensor has contact with the rising feed fluid the pump switches on.
The pump switches off as soon as the level sensor loses contact with the falling feed fluid and an after-running time of 15 s has passed.
For switch-on height / switch-off height see the following table:

Switch-on points SP 7 Dirt Inox

Depending on the position of the level sensor 55 – 240mm

NOTICE
Ensure that the pump is level.
Otherwise, it can happen that the level sensor does not lose the fluid contact and the pump runs dry.

  • Push the level sensor to the desired switch-on height (contact with feed fluid).

NOTICE
The higher the level sensor is adjusted, the higher the switch-on and switch- off point.
See the following table for application examples:

Min/Max SP 7 Dirt Inox

Shaft with a diameter < of approx.
1 m (e.g. drainage)| Level sensor in the upmost position
Pre-filter flaps closed (protection against soiling)
Swimming pool, pond, or the like| Level sensor in the lowest position
Pre-filter flaps closed (protection against soiling)

Finish operation

NOTICE
Soiling can deposit and lead to malfunctions.

  • Pump clear water or thoroughly rinse the pump after every use.
    This especially applies after pumping chlorinated water or other liquids that leave a residue.

  • Disconnect the main plug from the socket.

Maintenance

The pump is maintenance-free.

Transport

CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the appliance during transport (see Specifications).
Lift and carry the pump on the carrying handle.
If you want to transport the appliance on a vehicle secure it from slipping.

Storage

CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the appliance when selecting a storage location for it (see Specifications).

Storing the pump
  • Completely drain the pump and allow it to dry.
  • Store the pump in a frost-free place.

Special accessories

2.997-100.0| Braided hose set| Flexible 1 1/4“ braided hose with hose clamp (30 – 40 mm) with wing
screw for a connection without tools.
Especially recommendable for the immersion pumps when removing large water quantities.
Max. operating pressure: 5 bar
---|---|---
6.997-346.0| Spiral hose, by the meter, 25 m, 1″| By the meter for cutting hoses to individual lengths.
2.645-247.0| Hose PrimoFlex, 50 m, 1″| Phthalate-free 1″ garden hose for draining away the water.

Troubleshooting

DANGER
Risk of mortal danger on account of electric shock!
To avoid risks, all repairs and replacement of spare parts may only be carried out by the authorized customer service personnel.

Fault Cause Remedy
The pump runs but does not transport Air in the pump Unplug and plug in the

mains plug of the pump repeatedly until the fluid is drawn
Suction area blocked| Pull out the mains plug and clean the suction area
Water level below the minimum fluid level| Immerse, whenever possible, the pump deeper into the feed fluid or pro­ceed as described in Chapter Opera­tion.
The pump does not run or suddenly comes to a standstill during operations| Power supply interrupted| Check fuses and electrical connec­tions
The thermal protection switch has switched off the pump due to over-heating| Pull out the mains plug, let the pump cool down, clean the suction area, and prevent dry running
Dirt particles have got jammed into the suction area| Pull out the mains plug and clean the suction area
The level sensor stops the pump| Check the position of the level sensor and correct it if necessary.

The pump stops 15 s after the level sensor has no water contact anymore.

The level sensor does not react as it is soiled| Clean the level sensor.
Pumping capacity is reducing| Suction area blocked| Pull out the mains plug and clean the suction area
Pumping capacity too low| The pumping capacity depends on the flow height, hose diameter, and hose length.| Observe the maximum delivery height, see technical data. If neces­sary, use a larger hose diameter or a shorter hose length.
Quick-Connect cannot be opened or closed.| Soiling in the plug system.| Remove and clean the clip.
The pump is running although there is no water contact with the level sensor| The level sensor does not react as it is soiled| Clean the level sensor.
The switch is on the manual operation (MAN)| Set the switch to automatic mode (AU-TO).

Specifications

| SP 7 Dirt Inox
---|---
Mains voltage| V| 230 – 240 V
Mains frequency| Hz| 50
Output Pnom| W| 750
Max. flow rate| l/h| 15500
Max. pressure| bar| 0,8
Max. flow height| m| 8
Max. immersion depth| m| 7
Max. grain size of the dirt particles that can be transported| mm| 30
Minimum fluid height| mm| 50
Residual fluid height| mm| 35
Weight (without accessories)| kg| 6,7

Subject to technical modifications!

KARCHER SP 7 Dirt Inox Mit Level Sensor und integriertem Vorfilter - Fig
3

The possible delivery rate is even larger:

  • the lower the delivery height
  • the larger the diameter of the hose used
  • the shorter the hose used
  • the lower the pressure loss caused by the connected accessories

| KARCHER SP 7 Dirt Inox Mit Level Sensor und integriertem Vorfilter - Fig
5|
---|---|---

KARCHER SP 7 Dirt Inox Mit Level Sensor und integriertem Vorfilter - Fig
7

http://www.kaercher.com/dealersearch

http://kaer.ch/er/?l=TwSoJtl9IUOwZyAe1rHDyw

Alfred Kärcher GmbH & Co. KG
Alfred-Kärcher-Str. 28 – 40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals