Electrolux EWF073CM5WA Air Conditioner User Manual

June 5, 2024
Electrolux

EWF073CM5WA Air Conditioner

MODEL
EWF073CM5WA EWF093CM5WA EWF123CR6WA

EWF073CR6WA EWF093CR6WA EWF183CR6WA

CONTENTS
Our design is based on the best efficiency and the lowest noise operation and it can keep the room comfortable. Please read this operating manual carefully before operating the unit and keep it for consultation.

Str uctur e mechanism and Installation

Function

1

Operating condition

2

Power requirement

2

Installation

3

Notes for installation

6

Operation procedure

Part identification

7

Air direction adjustment

7

Main switch operation procedure (Applicable to Mechanical Models ONLY)

8

Operation of wireless remote control (Applicable to Remote Control Models ONLY) 9

Operation tips

15

Care and maintenance

Caution

16

Care and maintenance

17

Trouble shooting guide

18

After service

19

Please read this operating manual carefully before operating the unit ……
The figures in this manual may be different with the material objects, please refer to the material objects for reference.

Function

Introduction

Room temp.

Spring

Autumn

Summer

Winter

Wind direction

Window type room air conditioners can regulate the room temperature and dry the room. It is convenient for your work,study and life. It can be widely used in residence, shop, hotel, office, library and laboratory, and so on.

Cooling in summer
In hot summer, Air conditioner can cool down the room air by transferring heat out.

Dehumidifying in rainy or humid season
Without reducing the room temp., air conditioner can dehumidify and make the room air dry and comfortable.
Dry

Heating in winter
(Only for heat unit)
In cold winter, Air conditioner can heat up room air.

Exchange fresh air
Open storm door to keep the fresh air in the room.

Fresh Air

1

Operating Condition

Please operate air conditioner in the correct conditions as following.

COOL mode operation

DRY mode operation

Outdoor temperature should be in range of 18 to 43 , otherwise it is possible for air conditioner to breakdown. Room humidity should be lower than 90%. Otherwise, it is possible for air conditioner to dew at air conditioner surface and even drop water after running for so much time. But this is normal.

Outdoor temperature should be in range of 18 to 43 , otherwise it is possible for air conditioner to breakdown.

Power requirement
Rated voltage and voltage range: 220V 10%
The electric components will be damaged when the voltage is too high. If the voltage is too low, the compressor will vibrate violently to damage the refrigerant system and easily cause the compressor and electric components not work. The ground must be connected. Special socket must be used. Furthermore, the socket and wiring must conform to the wiring regulations. And the earthing method must be reliable. In fixed circuit, there must be electricity leakage protection switch of enough power capacity and air switch with enough space.
Earth wire To ensure the reliable earthing, please do not connect earth wire to the following places:
Water pipe
2

Installation
Installation precaution:
Window type conditioner is so valuable and the improper installation of it will cause a lot of damage! Please associate the professional technician to install the unit and don’t install it by yourself. Otherwise, we are not responsible for the damage like this.

Notice:
· This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
· The appliance shall be installed in accordance with national wiring regulations or similarly qualified persons in order to avoid a hazard. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent.
· Please read this operating manual carefully before operating the unit. The figures in this manual may be different with the material objects, please refer to the material objects for reference.

Location:

The condensation water must be drained away conveniently. Install air conditioner unit far away from TV set or radio
etc. to avoid disturbing video or voice. In salt and coastal area or place where is near thermal springs
and polluted by sulphurous gas, or other special areas, please
contact the seller before use. Avoid a place where is possible for inflammable gas to leak out.

Avoid other heat sources or direct sun light. Avoid a place where is easy for children to touch. Don’t use the unit in the immediate surrondings of a laundry,a bath,a shower or a swimming pool. For window type air conditioner with remote control, install in a location where is strong elec-
tromagnetic disturbance, you should contact the seller in advance to avoid the malfunction in use.

How to install:
Choose a location where there are no any obstacle surrounding the unit, and the plug is accessible. Prepare the installation hole slightly bigger than unit size. Choose the installation space according to the following diagram.
The indoor distance from obstructions should be 300mm (above), 1500mm (below), 500mm (left), 500mm (right) and 1500mm (front). The outdoor distance from obstructions should be over 150mm (above, left, right) and over 500mm (back). Please refer to the drawing below.

3

Installation procedure:

  1. Remove the sticker from the front panel. 2) Put the unit into the installation hole.
    When installing the unit, it should be slanted down to the back to avoid the enlargement of noise or vibration. (Slant between 6-10mm.) (Shown at right figure.) The installation place should be strong enough to avoid the enlargement of noise or vibration. 3) Fill up sews in the cabinet with sponge or foam.

Installation assistance:
Use iron support The installation hole should be strong enough to support the air conditioner. If it cannot, iron support has to be used outdoors. Iron support should be fixed on the building (Shown at right figure.) Use sunshade board Air conditioner should avoid anything to be dropped into it and avoid direct sunshine. If there is no cover on it, you should contact the seller for installing the sunshade board. When installing the sunshade board, don’t let it block the air inlet at the side grille.

Wall Wooden frame Rubber plate

Horizontal line
Sunshade board Support Horizontal line

4

Drain water for one style:
To get the maximum cooling efficiency,the air conditioner is designed to splash the condensate on the condenser coil. If the splashing sound annoys you, you can provide an outside drain by using the following procedure, which may however cause a small loss of performance. 1.There is a drainage outlet at the back of the unit. 2.Remove cover from the drainage outlet , and then connect drainage joint to it with screw. 3.Connect the drain hose to the outlet. Note: Drain hose or tubing can be purchased locally to satisfy your particular needs.

Drainage outlet Washer
Drainage joint

Remove

Install

Cover

Drain water for another style:

To get the maximum cooling efficiency, the air conditioner is designed to splash the condensation water on the condenser coil. To the cooling only unit,If the splashing sound annoys you, you can provide an outside drain by using the follo -wing procedure, whichmay however cause a small loss of performance. 1. Slide out the chassis from the cabinet. 2. Remove the rubber plug from the body base plate. 3. Install the drain pan to the corner of the cabinet with 2 screws. 4. Connect the drain hose to the outlet on the drain pan bottom. 5. Slide the chassis into its original place in the cabinet.

Note:
Drain pan and drain hose must be installed before using reverse cycle models. Drain hose or tubing can be purchased locally to satisfy your particular needs.
5

Notes for installation
Remove
Before removing air conditioner to the other place, you should contact the seller firstly. Then it must be done under the direction of the professional technician. In addition, the charge of this must be paid.
Noise
Install in a location where is firm enough to avoid the enlargement of noise and vibration. Don’t put anything in front of the outlet of outdoor unit to avoid increasing noise. Be sure that hot air or noise will not inconvenience neighbors. Please contact the seller as soon as there is strange noise during operation. Please use the safety support.
Electric wiring
Must connect with ground reliably. The exclusive circuit must be used. But removable socket can’t be used because poor contact of it can cause over heat or fire. Don’t pull the power cord strongly. In fixed circuit, there must be electricity leakage protection switch and leakage current is less than 30mA. Connecting method between air conditioners and power cord and interconnecting method of each individual element with one another should accord with wiring diagram on the unit. The air conditioner should be installed in accordance with national wiring regulation. An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring Air switch (thermal-magnetic breaker) should be installed in the circuit. If the supply cord is damaged,it must be replaced by the manufacturer or your dealer or a qualified person to avoid a hazard. All The dectrical work must be done according to the local wiring regulations.
6

Parts identification
Mechanical Model
Panel outlook picture, just for reference, please take the real unit as standard.
Cabinet
Air inlet louver
Front grille

Front intake grille

Air filter (behind the front intake grille)

Control panel

Power cord

Remote Control Model
Panel outlook picture, just for reference, please take the real unit as standard.
Cabinet

Air inlet louver

Front grille

Front intake grille

Air filter

Remote control panel Power cord

(behind the front intake grille)

Air direction adjustment

Vertical airflow direction vane
(Airflow direction adjustment up and down).
The vertical airflow direction vane is controlled by positioning the vane to discharge the air upwards, downwards or straight out.
7

Main switch operation procedure (Applicable to Mechanical Models ONLY)
1.Main Control Knob Set to Low Cool,Med Cool or High Cool as desired (FAN setting operates the fan only.) CAUTION:If the main control knob is turned off changed to a fan setting from a cooling operation setting, WAIT at teast 3 minutes before resetting to cooling operation.
2.Thermostat control Knob Set the thermostat control knob to your desired setting(Usually 6-7 is recommended). If the room temperature is not as desired after a reasonable period, turn the thermostat.When the thermostat control knob is set to 10, moisture may freeze onto evaporator fins and turn the thermostat control knob counter clockwise. This will quickly defrost the evaporator fins so that mormal cooling can be resumed.
3. Air Swing Switch (Airflow direction adjustment Side-to Side)
To obtain a fix airflow direction, set the air swing switch to “ON” for the vanes to swing from side to side until the desired flow direction is reached, then switch it to “OFF”. For continuous side-to-side air circulation, set the air swing switch to “ON”.
8

Operation of wireless remote control (Applicable to Remote Control Models ONLY)

Name and function of wireless remote control

Note: Besure that there are no obstructions between receiver and remote controoler; Don’t drop or throw the remote control; Don’t let any liquid in the remote control and put the remote control directly under the sunlight or any place where is very hot.

Signal transmitter
Remote control

SLEEP FAN

SLEEP button
Press this button, Sleep On and Sleep Off can be selected. After powered on, Sleep Off is defaulted. After the unit is turned off, the Sleep function is canceled. After Sleep function set up, the signal of Sleep will display. In this mode, the time of timer can be adjusted. Under Fan and Auto modes, this function is not available.
FAN button
Press this button, Auto, Low, Middle, High speed can be circularly selected. After powered on, Auto fan speed is default. Under DRY mode, Low fan speed only can be set up.

ON/OFF MODE

ON/OFF button
Press this button, the unit will be turned on, press it once more, the unit will be turned off. Sleep function will be canceled, while unit off.
MODE button
Press this button, Auto, Cool,Dry, Fan, Heat mode can be selected circularly. Auto mode is default while power on. Under Auto mode, the temperature will not be displayed; Under Heat mode, the initial value is 28 ( 82 oF); Under other modes, the initial value is 25 ( 77 oF).

AUTO
COOL
DRY
FAN
HEAT (only for cooling and heating unit As for cooling only unit, it won’t have any action when it receives the signal of heating operation.)

Low fan High fan

Middle fan

AUTO CLOCK

AUTO button
Press this button to active the “AUTO” function and the unit will be running according to room temperature.
CLOCK button
Press this button, the clock can be set up, signal blink and display.Within 5 seconds, the value can be adjusted by pressing + or – button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten place of Minute will be increased 1.During blinking, repress the Clock button or Confirm button, signal will be constantly displayed and it denotes the setting succeeded. After powered on, 12:00 is defaulted to display and signal will be displayed. If there is signal be displayed that denotes the current time value is Clock value, otherwise is Timer value.

9

Name and function of wireless remote control

Note: This wireless remote control is universal, andit could be used for many units, some buttons of this control which are not available to this unit will not be described below.

  • + button

Remote control

ENERGY SAVER
ENERGY SAVER button

Under the Cool and Dry mode, press this button once, the unit will enter “energy saver” mode. Repress this button, the unit will exit “energy saver” mode. Note: Not applicable for inverter models.

FAST COOL

FAST COOL button

Press the “FAST COOL” button to active the Fast Cool feature. When Fast Cool is activated, the air conditioner will automatically run at the highest fan speed with the set temperature of 16ºC.

LIGHT

Presetting temperature can be increased. Press this button, the temperature can be set up, continuously press this button and hold for two seconds, the relative contents can quickly change, until unhold this button and send the order that the R) signal will be displayed all the time. The temperature adjustment is unavailable under the Auto mode, but the order can be sent if pressing this button. Temperature of Celsius degree setting: 16-30; for Fahrenheit degree setting: 61-86.
– button
Presetting temperature can be decreased. Press this button, the temperature can be set up, continuously press this button and hold for two seconds, the relative contents can quickly change, until unhold this button and send the order that the R) signal will be displayed all the time. The temperature adjustment is unavailable under the Auto mode, but the order can be sent by if pressing this button.
LIGHT button
Press this button at unit On or Off status, Light On and Light Off can be set up. After powered on, Light On is defaulted.

10

Name and function of wireless remote control
Note: This wireless remote control is universal, and it could be used for many units, some buttons of this control which are not available to this unit will not be described below.

Remote control
SWING
SWING BUTTON
When it is pressed, the louvers start to rotate automatically and stop when repressed.

TIMER ON
TIMER ON BUTTON
At unit off, press Timer On button, “HOUR ON” will blink and display, signal
will be concealed, in the timer on setting. During 5 seconds blinking, the value can be adjusted by pressing + or – button, every press of this button, 0.5 hour will be increased or decreased, but continuously press the + or – button, 2 seconds later, the value will be changed quickly, 0.5 hour will be increased in every 0.25 second automatically by the remote controller. During blinking, press the Timer On button to confirm the time. After Timer On set up, when repressing the Timer On button, the Timer On setting will be canceled. After powered on, no Timer is defaulted, signal “HOUR ON (OFF)” will not display, and only the clock is displayed. After the timer reached, the relative contents with Timer will conceal. Before setting the Tmer, please adsult the clock to the current actual time.
TIMER OFF
TIMER OFF BUTTON
At unit on, press Timer Off button to enter into Timer Off setting.The method of
setting is the same as for TIMER ON.

11

Guide for operation- general operation
1. After powered on, press ON/OFF button, the unit will start to run. (Note: When it is powered on the guide louver of main unit will close automatically.)
2. Press MODE button, select desired running mode. 3. Pressing +or – button, to set the desired temperature (It is unnecessary
to set the temp. at AUTO mode.) 4. Pressing FAN button, set fan speed, can select AUTO FAN, LOW, MID
and HIGH. 5. Pressing SWING button, to select the swing.
Guide for operation- Optional operation
1. Press SLEEP button, to set sleep. 2. Press TIMER ON and TIMER OFF button, can set the scheduled timer on
or timer off. 3. Press LIGHT button, to control the on and off of the displaying part of the
unit (This function ay be not available for some units). 4. Press ENERGY SAVER button, can realize the ON and OFF of
ENERGY SAVER function.
Introduction for special function
About AUTO RUN When AUTO RUN mode is selected, the setting temperature will not be displayed on the LCD, the unit will be in accordance with the room temp. automatically to select the suitable running method and to make ambient comfortable.
About lock Press +and – buttons simultaneously to lock or unlock the keyboard. If the remote controller is locked, the icon will be displayed on it, in which case, press any button, the mark will flicker for three times. If the keyboard is unlocked, the mark will disappear.
12

About switch between Fahrenheit and Centigrade Under status of unit off, press MODE and – buttons simultaneously to switch and .

Changing batteries and notices

1. Slightly to press the place with , along the arrowhead direction to push the back cover of wireless
remote control. (As show in figure)
2. Take out the old batteries. (As show in figure) 3. Insert two new AAA1.5V dry batteries, and pay attention to the polarity.
(As show in figure)
4. Attach the back cover of wireless remote control. (As show in figure)

NOTE:
When changing the batteries, do not use the old or different batteries, otherwise, it can cause the malfunction of the wireless remote control. If the wireless remote control will not be used for a long time, please take them out, and don’t let the leakage liquid damage the wireless remote control. The operation should be in its receiving range. It should be placed at where is 1m away from the TV set or stereo sound sets.
If the wireless remote control can not operate normally, please take them out, after 30s later and reinsert, if they cannot normally run, please change them.

Sketch map for changing batteries

13

Remote control panel
Note:
If wireless remote controller is lost, open the surface panel and operate manually.

1 POWER BUTTON Operation starts when pressing this button, and stops when pressing this button again.
2 SWING BUTTON Activate the automatic air swing function.
3 FAN SPEED BUTTON Select the fan speed HIGH, MID, LOW and AUTO in sequence.
4 TEMP/TIMER BUTTON Press the keypad to increase the set (operating) temperature of the unit. and Press the keypad to decrease the set (operating) temperature of the unit. The temperature seting range is from16~30
Press the keypad also to increase the selected time in 1 hour increments, and Press the keypad to decrease the selected time in 1 hour decrements, The time seting range is from 0~24 hours.

5 SIGNAL RECEIVER
6 MODE BUTTON Select the operation mode, or AUTO,COOL,FAN, DRY.
7 FILTER BUTTON This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation and cooling. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the “Check Filter” button and the light will go off.

VENTILATION LEVER
When the slider at the:

When the slider at the:

-“OPEN” position, the ventilation door opens to allow air,smoke or odors to
be expelled from the room.

-“CLOSE” position, the ventilation door is closed and the air will be circulated
inside the room and conditioned.

Ventilation Lever

14

Operation Tips

Operation for comfort and economy

Do not overcool the room temperature. This is not good for health and wastes electricity.

Keep blind or curtains closed. Do not let sunshine enter the room directly when the air condition is in operation.

Keep the room temp. uniform. Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room. Air can’t be discharged to the direction of air-in.

Make sure that the doors and windows are tightly closed.Avoid opening doors and windows as much as possible to keep air conditioning in the room.

Clean the air filter regularly. Blockages in the air filter reduce dehumidifying effects. Clean the air filter at least once every two weeks.

Ventilate the room occasionally. Since windows are kept closed, it is a good idea to open them and ventilate the room now and then. When starting the unit, curtains or windows should be closed to prevent the heat/cool leakage.

15

Caution
Operations for safety and health

  1. The plug must be accessible after the appliance is positioned. 2) Do not use this appliance in the laundry. 3) If the power cord is damaged, it must be replaced by the manufacture or its service agent in void of hazard.

Do not pull out the power cord. Damage to the cord may result in serious electric shocks.

Do not use the air conditioner for other purposes except for cooling the room. Do not use the air conditioner for other purposes such as drying clothes, preserving foods, or cultivating vegetables.

Do not block the air intake and outlet vents This causes lowered performance and irregular operation. Do not insert sticks or other objects into these vents as it is dangerous to touch the electric components and the fan.

Select the most appropriate temperature. Pay attention to adjust the temperature to suit the conditions. Rooms occupied by infants,the elderly, or the sick should be kept at an appropriate temperature.

Do not use heating apparatuses in the vicinity.The air conditioner s plastic parts will melt if exposed to excessive heat.

Avoid exposing the body directly to a continuous unidirectional air flow for long periods. This is not recommended for health reason.

Always wait at least 3 minutes before switching the air conditioner on again after you have switched it off during cooling or heating.
16

Always wait at least 3 minutes

Care and maintenance

Always turn off the air conditioner and main power supply before cleaning to ensure safety.
Cleaning unit

1. Cut power off before cleaning.
Plug out only after air conditioner stops at all.

2. Use soft cloth when cleaning cabinet. If the cabinet is very dirty, dip cloth into warm water below 40 dry
the cloth and then rub off the dirt.

Dry the cloth by hands before cleaning.

Air filter The air filter behind the intake grille should be washed at least once every two weeks or as often as it needs cleaning. How to clean the air filter: 1. To remove the air intake grille, grasp the tab on the filter and pull to take out.
2. Vacuum the filter on the dusty side to remove light dust.

3. Don’t use gas, benzene, solvent,wash, chemical solvent, etc. for cleaning.

Vacuum cleaner 3. Wash the filter, cleaner side up under gently flowing water to wash out accumulated dust and lint.

4. Do not splash water directly into indoor

unit, in which

there are micro-

computer and

circuit plate,

they must not be drenched with water.

Accident could happen.

  • Check earth wire

Is it broken or loose?

4. If the filter is very dirty, use a mild household detergent in the wash water.
Let the filter dry thoroughly before reinstalling it. If. necessary, please ask the professional personnel to clean it.

  • Check if air inlet and outlet of outdoor unit are blocked or not.
    Air lock could result in bad efficiency.

17

Trouble shooting guide
Please check the following items before asking for repair,it saves your time and money.

Fault phenomenon
Air conditioner dose not operate at all.

Trouble-shooting

  • Is there a power failure? Is the plug out? Is power fuse or switch off ? * Whether the voltage is too high or too low?

Cool or heat efficiency is not good.

  • Is air inlet or outlet locking? Is there any other heat/cool source in room? Are air filters dirty very much? Is indoor fan speed set at LOW? Maybe the room is too hot/cool when the unit is
    started.

Foggy air flows out.
The air conditioner operation is noisy.

  • At COOL mode operation, sometimes there is foggy air flowing out of indoor unit, this is because the room humid air has been cooling rapidly.

  • The unit is normal while the indoor outlet is sending out some odor, because the inlet air may be mixed with the smell of furniture and smoke.

  • For a noise that sounds like water flowing: This is the sound of freon flowing inside the air conditioner unit.

  • For a noise that sounds like a shower: This is the sound of the dehumidifying water being processed inside the air conditioner unit.

  • Condensation occurs when the airflow from the air It seems that condensation is leaking from air conditioner.
    conditioner cools the warm room air.

Air conditioner dose not operate for about 3 minutes when * This is to protect the mechanism.

restart.

  • Wait about three minutes and operation will begin.

18

Immediately stop all operations and plug out, please contact your dealer in the following situations.
Operation starts or stops abnormally; Power fuse or switch often breaks; Carelessly splash water or something into air conditioner; Electrical lines are much hot or lines cover breaks; *Other strange situations.
After service
If your air conditioner has the questions of quality or anything else, please contact the service center of Electrolux.
19

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals