  1. Read all instructions.
  2. Use heat press only for its intended use.
  3. To reduce the risk of electric shock, do not immerse the heat press in water or other liquids.
  4. Never pull cord to disconnect from outlet, instead grasp plug and pull to disconnect.
  5. Do not allow the cord to touch hot surfaces, allow the heat press to cool completely before storing.
  6.  Do not operate heat press with a damaged cord or if the equipment has been dropped or damaged. To reduce the risk of electric shock, do not disassemble or attempt to repair the heat press. Take it toa qualified service person for examination and repair. Incorrect assembly or repair could increase the risk of fire, electric shock, or injury to persons when the equipment is used. The power supply cord must be disconnected before cleaning or servicing the press.
  7. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  8. Close supervision is necessary for any heat press being used by or near children. Do not leave equipment unattended while connected.
  9. To avoid burns, do not touch hot metal parts or the heated platen during use.
  10. To reduce the likelihood of circuit overload, do not operate other high voltage equipment on the same circuit.
  11. If an extension cord is necessary, then a 20-amperage-rated cord should be used. Cords rated for less amperage may overheat. Care should be taken to arrange the cord so that it cannot be pulled or tripped over.
  12. Keep hands clear of the upper heat press plate during lockdown as the pressure may cause injury.
  13. The heat press should be placed on a sturdy, suitable stand at least 90cm L x 60 cm W x 75 cm H.
  14. Work area must be kept clean, tidy and free of obstructions.

Machine View

Hotronix-Heat-Press-360-IQ-Cap-
Press-1

Operating Instructions

Connecting the System

  1. Insert power cord into IEC Inlet located on the side of press (1.1). Connect the power cord into a properly grounded electrical outlet with a sufficient amperage rating. To remove a locking power cord (if equipped), press the two red buttons while pulling on the plug (1.2).

  2. Voltage
    120-volt presses require a full 6-amp grounded circuit. 240-volt presses require a full 3-amp grounded circuit.

  3. Extension Cords
    If used, extension cords should be as short as possible and not less than 12 gauge. Heavy-duty cords are recommended.

  4. Circuits
    Circuits that have less than 10 amps, or have other high-demand equipment or appliances (especially more than one heat press) plugged in, should not be used.
    Note: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person to avoid hazards. Use SJT type rated 300 V cord for replacement.

  5. Start-Up/Shut Down
    Locate the packaging bolt on top of press and remove prior to turning on or operating (2.1). Flip the power switch ON (2.2). A splash screen displaying the Hotronix® logo and current software version is shown for several seconds. To turn heat press off, flip the power switch OFF.

To place heat press into Standby Mode, touch and release the Power icon on the Home Screen (3.2 – following page). In Standby Mode, the heater turns off while the Touch Screen remains on, displaying an orange background as a warning if the platen is still hot (above 100°F/38°C).
NOTE: Standby Mode must be used for the Auto On feature to function (10.1).
The Auto On feature will not work if the power switch (2.2) is in the OFF position.To start up your heat press while in Standby Mode, touch and release the Home icon on the Standby Screen.

Home Screen

Hotronix-Heat-Press-360-IQ-Cap-Press-6 Hotronix-Heat-Press-360-IQ-Cap-
Press-7Prepare to Print

Before heat applying, set the target settings for the selected transfer material by:

  • Selecting a Preset (7.1), or
  • Manually entering target temperature, time, and pressure.

Temperature and time are controlled automatically. Pressure must be set manually:

  • Position a cap on the lower heater (4.1).
  • Lower the cap hold-down lever (4.2) to lock in place.
  • Enable Target Temp option in System settings (11.1) to prevent the electromagnet from locking down until temperature is reached.
  • Pull lift handle down and observe the pressure reading.
  • Adjust the pressure by turning the Pressure Adjustment Knob.

A visual pressure readout is located on the Home Screen. When the handle is locked in the PRINT position, a pressure number between 0-9 is displayed.

  • 0 = No Pressure.
  • 1 – 3 = Light Pressure.
  • 4 – 7 = Medium Pressure.
  • 8 – 9 = Heavy Pressure.

WARNING: Structural damage caused by excessive pressure is not covered under the limited warranty!
The lower heater alignment can be adjusted by loosening the knob to accomodate different cap sizes (4.3). When the desired temperature is reached:

  • Position the cap and design (4.1).
  • Lower the cap hold-down lever to lock cap into place (4.2).
  • Pull lift handle down and begin to heat apply.
  • The automatic timing process will begin.
  • The Home Screen will initiate a count down and lift the heat platen into the UP position when print cycle is complete (4.4).

Tips for Successful Printing:

  • Hold hat by the sides of bill and load from side of platen.
  • Align seam of bill with lip on lower platen for access to full print area.
  • Extend sweatband out when possible to ensure smoother application.
  • Cover logo with included pad matching thickness of material.
  • Always best to remove hat from press before peeling backing to let adhesive cool and set.
  • Don’t pick or pull at emblem or patch for 24 hours to ensure adhesion.
  • Please use following application instruction for our CAD-CUT® and CAD-COLOR® Vinyls: 1/8” thick white cover pad, bottom heat 160°C, medium pressure, 45 secondes, peel cold.

Watch this video for more helpful tips: bit.ly/htx-360

Touch Screen Guide

Setup Menu

  1. Touch the Settings icon on the Home Screen (5.1) to configure your heat press.
  2. Managers can access all setup options, while Users can access a limited set (5.2).
  3. Managers default password: M

Password Setup (Manager-Level Only)

  1. Touch the User icon on the Home Screen (6.1) or Setup Menu (6.2) to select, add, and edit Users.
  2. Touch and edit Managers and Users to configure access to settings (6.3, 6.4). Heat press reports on the IQ® Portal can be filtered by User to track individual operator performance.
  3. Touch arrow keys on the taskbar to scroll through a long list of Users (6.5).

Preset Setup

  1. Touch the Columns icon (7.1) to select from a list of saved presets (7.2).
  2. Touch arrow keys on the taskbar to scroll through a long list of presets (7.3).
  3. Touch a preset to select a material.
  4. Touch the Pencil icon (7.4) to enter edit mode, then touch preset name to edit settings. Touch Save to save changes.
  5. Touch the Plus icon to create a new preset (7.5).
  6. Name your preset and enter desired temperature, time, and pressure. When creating a new preset, the current Home Screen application settings are selected automatically (7.6).
  7. Touch the empty circled numbers to set multiple preset stages for pretreatment or multi-step applications (7.7).

Date & Time Setup
Touch the Settings icon on the Home Screen.

  1.  Touch Date & Time, information displays on right of screen (8.1).
  2. Touch up/down arrows to select time zone.
  3. Touch Auto to automatically synchronize the heat press clock. The heat press must be connected to a WIFI network with access to the Internet.
  4. Touch Daylight Saving to enable daylight saving mode.
    This option should be enabled during summer.

Display Setup
Touch the Settings icon on the Home Screen.

  1. Touch Display, information displayed on the right of the screen (9.1).

  2. Touch Temperature to switch between F° or C°, then touch Check Mark icon on taskbar to save.

  3. Auto On & Off Setup
    Touch the Settings icon on the Home Screen.

  4. Touch Auto On/Off, information displays on right of screen (10.1).

  5. Touch Enable, then On Hour/Minute and Off Hour/Minute, selecting Enter between each setting. Once entered, touch Check Mark icon on taskbar to save.

NOTE: Standby Mode must be used for the Auto On feature to function (3.1).
The Auto On feature will not work if the power switch (2.2) is in the OFF position.
System Setup (Manger-Level Only)
Touch the Settings icon on the Home Screen.

  1. Select System, information displays on right of screen (11.1).
  2. Touch Power Save and select time, then touch Check Mark icon on taskbar to save. When enabled, your heat press will enter Standby Mode if it’s not used for the specified number of hours.
  3. Touch Target Temp to prevent the electromagnet from activating until temperature is reached.

Calibration (Manager-Level Only)
Your heat press comes pre-calibrated from the factory. Calibration is only required after sensor or controller replacement. Pressure is periodically self-calibrated. Incorrect calibration can result in poor print results or damage to your heat press which is not covered by warranty. Your heat press has a temperature calibration function (12.1).

  1. Turn on heat press and heat to 350°F/177°C.
  2. Measure center of heater with contact thermocouple (not infrared) thermometer.
  3. Touch the Settings icon on the Home Screen.
  4. Touch Calibration, information displays on right of screen.
  5. Touch Temperature 1 for the top heater and adjust Temperature Calibration to match Target Temperature.
  6. Touch Temperature 2 for the bottom heater and adjust Temperature Calibration to match Target Temperature. Remove rubber cap and adjust 100°F below measured temperature for best results.

Your heat press has a pressure calibration function (12.2).

  1. Touch the Settings icon on the Home Screen.
  2. Touch Calibration, information displays on the right of screen.
  3. Touch Pressure and then Calibrate. Wait for the screen to display 2.5V.
  4. Turn Pressure Adjustment Knob counterclockwise (reducing pressure) until it stops.
  5. Place one thin (1/8″ 3mm) white pad on mandrel, lower print handle into print position until electromagnet lightly contacts magnet plate.
  6. Tap Set Min Point (screen should display reading of approximately 2.5V).
  7. Raise print handle.
  8. Turn Pressure Adjustment Knob clockwise (increasing pressure) 3 full turns, lower print handle into print position until electromagnet lightly contacts magnet plate.
  9. Tap Set Max Point (screen should display reading around 2.1V to 2.4V).
  10. Raise print handle.

Updating Software
Touch the Settings icon on the Home Screen.

  1. When a software update is available, an exclamation point appears after the version number in the Setup Menu (5.2). Touch Firmware, information displays on right of screen. An available online update displays a Cloud icon (12.3).
  2. Touch Update File on right of screen, then touch Check Mark icon on taskbar to start the download. A downloaded update displays a Memory Card icon.
  3. Touch Downloaded Update File on right of screen, then touch Check Mark icon on taskbar to start the installation.

NOTE: If a power failure occurs during installation, the heat press will attempt to install the previous software version.

Connect to the IQ PORTAL

Create Your Account

  1. Using a phone or computer, visit iq.hotronix.com to create an account (13.1).
  2. Enter your name, email, and password.
  3. Click on the confirmation link in the email you receive.
  4. Your account has been created.

Register a Heat Press

  1. Click on Manage Heat Presses, then New Heat Press.
  2. Select heat press type, enter serial number, and enter a name for the heat press (optional).
  3. Click on Create Heat Press and enter the verification code given.
  4. On the heat press Setup Menu, touch WIFI and connect to your WIFI router or mobile hotspot (13.2).
  5. On the heat press Setup Menu, touch the Cloud icon and enter the verification code displayed in the IQ® Portal (13.3).
  6. Your heat press has been registered.

Create & Assign Users

  1. Click on Manage Operators, then New User.
  2. Enter a name and select a privilege level. Managers can access all heat press settings while Users have limited access.
  3. Click on New User, then Assign Machines in the sidebar.
  4. Select a machine and click Assign.
  5. On the heat press Setup Menu, touch the Cloud icon, then Manual Sync (13.4).
  6. Reporting will show impressions made by Users.

Electrical Schematic

Hotronix-Heat-Press-360-IQ-Cap-
Press-37Replacement Parts ListHotronix-Heat-
Press-360-IQ-Cap-Press-38Parts Location Guide Hotronix-Heat-Press-360-IQ-Cap-Press-39

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hotronix User Manuals

Related Manuals