GENERAL SAFETY INSTRUCTION

  1. This manual is an integral part of the product. Keep it within a safe place, and hand it on to the next user/owner in case of a change of property.

  2. Read the instructions and warnings in this manual carefully, they contain important information regarding safe installation, use, and maintenance.

  3. The appliance must be installed and commissioned by a competent person in accordance with local legislation and health and safety regulations. All electrical power supplies to the unit must be isolated and made safe before you open the terminal block.

  4. DO NOT use the appliance for anything other than its specified use. The manufacturer is not liable for damage resulting from improper or incorrect use or failure to observe the instructions given in this manual.

  5. Incorrect installation can result in damage to property and injury to persons and animals; the manufacturer is not liable for the consequences.

  6. DO NOT leave the packaging materials (staples, plastic bags, expanded polystyrene, etc.) within the reach of children – they can cause serious injury.

  7. This appliance can be used by children aged 3 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. DO NOT permit children to play with the appliance. User cleaning and maintenance may not be done by unsupervised children.

  8. Any repairs, maintenance, plumbing, and electrical connection must be done by a competent person using original spare parts only. Failure to observe the above instructions can compromise the safety of the appliance and relieves the manufacturer of any liability for the consequences.

  9. The hot water temperature is regulated by a thermostat which also acts as a safety device to prevent dangerous overheating.

  10.  The electrical connection must be done as indicated in this manual.

  11. If the appliance is equipped with a power cable, the latter may only be replaced by an author-
    ised service center or a professional technician.

  12. Make sure to drain the appliance when it is out of service or in an area subject to subzero
    temperatures.

  13. Do not leave flammable materials in contact with or in the vicinity of the appliance.

  14. DO NOT touch the appliance when barefoot or if any part of your body is wet

  15. Before using the device and after routine maintenance, we recommend flushing the unit to remove any debris.

  16. Do not place anything under the water heater which may be damaged by a leak.

Symbol Meaning
Failure to observe this warning can result in injury, which may even be

fatal in certain circumstances
| Failure to observe this warning can result in damage or injury, even to property; plants, and animals
****| Observe the product’s general and specific safety instructions.

GENERAL SAFETY STANDARDS

Ref. Warning Risk Symbol
1. Do not open the appliance or remove it from its installation

Electrocution hazard due to the presence of live electrical equipment. Personal injury -overheated burns caused by components and wounds caused by sharp edges|
2.| Do not start or stop the appliance by inserting/ pulling the power plug| Electrocution hazard due to damage to the power cord, its plug, or the socket|
3.| Do not damage the power cable| Electrocution hazard due to bare live wires|
4.| Do not leave objects on the appliance| Personal injury due to objects falling off the appliance as a result of vibration|
Damage to the appliance or other property due to objects falling off the appliance as a result of vibration|
5.| Do not climb onto the appliance| Personal injury due to falling off the appliance|
Damage to the appliance or other property due to the appliance itself detaching from its mounting|
| Do not clean the appliance without having first
isolated the electrical power supply to the unit.| Electrocution hazard due to the presence of live electrical equipment|
| Install the appliance to a solid wall that is not subject to vibration| The danger of the appliance falling off the wall due to structural collapse|
8.| Make the electrical connection with cables of adequate cross-section| The danger of fire due to overheating of undersized electrical wires|
9.| Restore all safety and control functions after working on the appliance and check that they are operational before returning it to service| Damage or blocking of the appliance due to improper control|
10.| Drain all components containing hot water, using the bleed cocks, before handling them| Danger of bums|
11.| Descale the system as given in the product “safety sheet”; when doing so, vent late the room, wear safety clothing, and make sure not to mix
products, and protect the appliance itself and any adjacent objects| Personal injury due to contact of the skin and eyes with add, inhalation, or ingestion of noxious chemicals|
Damage to the appliance and adjacent objects due to corrosion by acid|
12.| Do not use insecticides, solvents, or aggressive detergents to clean the appliance| Damage to plastic and painted parts and assemblies|

TECHNICAL CHARACTERISTICS

For the technical specifications, refer to the nameplate (the nameplate is located on the right side of the water heater).

PRODUCT INFORMATION

Model AURES| M 9.5 240V EU
Power (kW)| 9.5
Voltage (V)| 240
Phases| Mono
Installation| Multipoint
Construction| Close outlet
Frequency (Hz)| 50/60
Electric current (A)| 39.6
Electrical diagram| III
Water Protection| IP25
Pipe Connection| 1/2″ BSP
Minimum water flow (l/min)| 2.1
Qelec (kWh)| 2.224
Max water pressure| 800 kPa (8 bar)
Load profile| XS
Lwa (dB)| 15
ηwh| 39%
Rated Volume (l)| 0.45
Weight (kg)| 2.2
Dimensions (mm)| 304 x 220 x 110

The power consumption data in the table and the other information given in the Product Data Sheet (Enclosure A to this manual) are defined in relation to EU Directives 812/2013 and 814/2013. The products without the label and the datasheet for water heaters and solar devices, stipulated in regulation 812/2013, are not intended to be used in such assemblies. Products equipped with a regulator knob have the thermostat positioned in the <ready to use setting indicated in the Data Sheet (Enclosure A), according to which the relevant energy class has been declared by the manufacturer.
The product should be connected only to an electrical supply with the relevant system impedance of no more than 0.237 ohms. Restrictions to connection may be imposed by the supply authority on the use of equipment in the actual relevant system impedance at the interface point on the user’s premise that exceeds 0.237 ohms. This appliance is conforming with the international electrical safety standards IEC 60335-1 and IEC 60335-2-35. When present, The CE marking of the appliances attests its conformity to the following EC

Directives, of which it satisfies the essential requisites:
– LVD Low Voltage Directive: EN 60335-1, EN 60335-2-35, EN 60529, EN 62233, EN 50106.
– EMC Electro-Magnetic Compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11 and EN 61000-3-12.
– ERP Energy-related Products: Eu812, Eu814, EN50193-1-2013
The UKCA marking of the appliances attests its conformity to the following UK legislation
– Electromagnetic Compatibility Regulations 2016
– Electrical Equipment (Safety) Regulations 2016
– The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019
– The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012

Installation Instructions:

The appliance must be installed and commissioned by a competent person in accordance with established regulations and local health and safety regulations.

  1. Before performing any operations, disconnect the electricity using the external switch
  2. Open the two screws located at the bottom of the device and remove the cover from the base.
  3. Fix the base horizontally against a wall or side of the cabinet, the inlet and outlet water pipes are on the down/bottom side of the unit. Use the four mounting screws provided.
  4. Use the supplied water filter on the inlet water pipeline (see diagram)
  5. Connect the incoming cold water pipe to the inlet connection point on the bottom right side and the outgoing hot water pipe to the outlet water pipe on the bottom left side. Turn open the water supply and check there is no water leakage from the unit.
  6. Use an all pole switch conforming with national laws in force (contact gap of at least 3 mm, preferably equipped with fuses) to disconnect the appliance’s power supply.
  7. Connect the power cable to the terminal block inside the unit. The appliance must be earthed and the earth cable must be fixed to the terminal marked by the symbol .
  8. Turn on the unit and check that it is operating as required.
  9. Reconnect the cover to the base with 2 screws.
  10. It is required that a Ground Fault Circuit Interrupter/Earth Leakage Circuit Breaker be incorporated into the circuit.
  11. Make sure to install the pressure relief valve correctly (supplied with the product) before the Inlet pipe.
  12. It is required to install a flow control restrictor (AERATOR) at the sink or shower.
  13. WARNING: THE UNIT MUST BE PROPERLY GROUNDED
  14. THIS HEATER MUST HAVE ITS OWN INDEPENDENT CIRCUIT USING A CORRECTLY RATED CIRCUIT BREAKER AND SUITABLE WIRE, SEE TABLE RECOMMENDED CABLE.

OPERATING INSTRUCTIONS

  1. Your new Instant Water Heater is flow-activated. Regulate the knob in one of the 3 setting power (I, II, III) the product will switch ON once the hot water tap is turned on, the heating element will work and warm the water only when there is a flow of water through the appliance. You will need to allow at least 2.1 liters per minute to flow through the unit in order to activate the Instant Heating System. Run water through the heater for a few minutes.
  2. Be sure to every so often clean the spray head to assure a smooth water flow.
  3. Be sure to every so often clean the incoming water filter.
  4. Be sure to install your Instant Water Heater in a heated location. The appliance cannot be installed in areas where the temperature may drop critically and there may be a risk that ice may form.
  5. The user can adjust the hot water temperature regulating the setting power on the unit. the user can choose from 4 different power settings:
    – O – The heating element is off
    – I – Only the 1st Heating element switches on.
    – II – Only the 2nd heating element switches on.
    – III – 1st and 2nd heating elements switch on, working together.

INSTALLATION REQUIREMENTS
A. A separate electrical supply is required.
B. The device must be connected to a separate circuit breaker.
C. The recommended electrical cable for supplying the device, see table I (next page)

INSTALLATION

See electrical diagrams at the end of the booklet.
WARNING!
BEFORE BEGINNING ANY WORK ON THE ELECTRICAL INSTALLATION BE SURE THAT THE CIRCUIT BREAKER IS IN THE “OFF” POSITION TO AVOID THE DANGER OF ELECTRICAL SHOCK

ATTENTION
The water inlet of this appliance must be connected directly to a cold water mains supply.
Table 1: Recommended cable

Power| kW Loaded| Heating setting| Recommended Cable| Recommended Fuse Rating
---|---|---|---|---
220V| 230V| 240V
AURES M 9.5 240V EU| —| —| 10.| 4.7+4.8 kW| HO5VV-F 3x6mm2 *| 40A
| • Operating water pressure 50-800 kPa (0.5-8 bar)
• Water pressure operating power switch
• Standard 1/2″Ø compression inlet connection
• Top-Left and Optional Top-right cable entry
• Bottom-right water entry
UNIT DIMENSIONS: HEIGHT 220mm WIDTH 304mm DEPTH 100mm

  • Recommended power cable size: 6mm2/10mm2 (in the UK 10mm2 is a requirement where it runs longer than 10 meters).

This product conforms to Directive WEEE 2012/19/EU.
The symbol of the crossed waste paper basket on the appliance indicates that at the end of its working life the product should be disposed of separately from normal domestic household rubbish, it must be disposed of at a waste disposal center with dedicated facilities for electric and electronic appliances or returned to the retailer when a new replacement product is purchased. The user is responsible for the disposal of the product at the end of its life at an appropriate waste disposal center. The waste disposal center (which uses special treatment and recycling processes effectively dismantles and dispose of the appliance) helps to protect the environment by recycling the material from which the product is made. For further information about waste disposal systems visit your local waste disposal center or the retailer from which the product was purchased.

Troubleshooting

SYMPTOM POSSIBLE CAUSE SOLUTION
The water is not hot enough Too much water flowing through the heater

Reduction In the ambient temperature
Water Pressure below 100 kPa
Electrical Malfunction| Reduce the flow rate of the water via the outlet tap.
Switch to a higher temperature setting.
Check if the mains stop valve is fully open and that there are no other restrictions in the supply line.
Have the Heater unit checked by a qualified electrician or contact your local authorized distributor.
Water too hot| Not enough water flowing through the heater
Increase in the ambient temperature| Increase the flow rate via the outlet tap Switch to the lower temperature setting
The heater switched Off during use| Interruption of mains electrical supply
ELSD trip, possible earth leakage| Check incoming power supply, MCB, switches, and supply cabling. Check earth leakage and reset ELSD
If the problem persists, call your local authorized distributor for assistance.
Water ceases to flow| Blockage of spray head twisted or blocked flexible shower hose.
No water supply.| Clean or replace the spray head, and check for free passage of water through a hose. Replace as necessary.
Check water supply, stop valve Open? and no blockage.
Water temperature varies from hot to cold during use| Water pressure has dropped below min. level.| Increase hot water supply,
No hot water despite a fully open hot water outlet| No electrical power
The activation flow rate needed to turn on the heating element has not been reached.| Check the circuit breaker and check the voltage at the wiring block.
Clean filter screen
•Turn the circuit breaker off
•Open the hot valve to release pressure from the unit.
•Turn circuit breaker on.

ELECTRICAL WIRING

Product sizes

Optional cable entry
Top-left cable inlet is for cable until 10 mm²
Optional top-right cable entry is only for power cable size: 6 mm²

Close cover Steps

Manufactured by:
Ariston Thermo S.p.A.
Viale Aristide Merloni, 45
60044 Fabriano (AN)
Tel. (+39) 0732.6011
ariston.com
Commercialized in the UK by:
Ariston Thermo UK
3 Juniper West
Basildon
SS15 6SJ
www.ariston.com/uk
e-mail: info.uk@aristonthermo.com
Customer Service: 0333 240 8777
Technical Advice: 0333 240 7777