Vesternet 8 Button Zigbee Wall Controller User Guide

June 3, 2024
Vesternet

Vesternet 8 Button Zigbee Wall Controller User Guide
Vesternet 8 Button Zigbee Wall Controller

Important: Read All Instructions Prior to Installation

Function introduction

Front side
Function

Back side
Function

Product Data

Operation Frequency 2.4GHz
Transmission Range (free field) 30m
Power Supply 3VDC (CR2450)
Operating temperature 0-40°C
Relative humidity 8% to 80%
Dimming Range 0.1%-100%
Dimensions 71.2×71.2×13.6mm
Protection Type IP20
  • ZigBee dim remote based on ZigBee 3.0
  • Enables to control both single color lighting devices
  • Battery powered remote with low power consumption
  • Enables to pair ZigBee lighting devices via touchlink commissioning without coordinator
  • Supports find and bind mode to pair with ZigBee lighting devices
  • Supports 4 groups for binding max. 30 lighting devices
  • 2.4 GHz global operation
  • Transmission range up to 30m
  • Compatible with universal ZigBee Gateway products
  • Compatible with universal single color ZigBee lighting devices

ZigBee CIusters Supported by This Remote Are As Follows:

Input clusters:

  • Basic
  • Power Configuration
  • Identify
  • Diagnostics

Output clusters:

  • Identify
  • Group
  • On/off
  • Level control
  • Ota

Safety & Warnings

  • This device contains a button lithium battery that shall be stored and disposed properly.
  • DO NOT expose the device to moisture.
  • Do not ingest battery, Chemical Burn Hazard
  •  This product contains a coin / button cell battery. If the coin / button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death
  • Keep new and used batteries away from children.
  • If the battery compartment does not close securely, stop using the product and keep it away from children.
  • If you think batteries might have been swallowed or placed inside any pa rt of the body, seek immediate medical attention.

Quick Start (Simplified operation compared to standard operations in the part “Operation”)
Operation instruction

  • Touchlink + Add Group 1: Press and hold down both keys for 3 seconds to start touchlink and link light device to group 1.
  • Touchlink + Add Group 2: Press and hold down both keys for 3 seconds to start touchlink and link light device to group 2.
  • Touchlink + Add Group 3: Press and hold down both keys for 3 seconds to start touchlink and link Iight device to group 3.
  • Touchlink + Add Group 4: Press and hold down both keys for 3 seconds to start touchlink and link light device to group 4.
  • Factory reset: click both buttons 3 times to reset the remote (the remote should already be paired to a gateway).

Network pairing mode: click both buttons 3 times to set the remote into network pairing mode (the remote should not belong to any gateway network).

Operation

  1. This ZigBee Dim remote is a wireless transmitter that communicates with a variety of ZigBee compatible systems. This transmitter sends wireless radio signals that are used to remotely control a compatible system.
  2. This Zig Bee remote suppo rts 4 grou ps for bin ding max. 30 fig hting devices and enab les to control sing Ie co for Zig Bee fighting devices.
  3. Zigbee Network Pairing through Coordinator or Hub (Added to a Zig bee Network)
    Operation instruction

Step 1: Remove the remote from previous zigbee network if it has  already been added to it, otherwise pairing will fail. Please refer to the part “Factory Reset Manually”.
Step 2: From your zigbee controller or hub interface, choose  to add device or accessory and enter Pairing mode as instructed by the controller.
Step 3: Press and hold down both until LED indicator turns on.
Step 4: Immediately short press to search nearby network, indicator flashes every 1 second, 20 seconds timeout if there is no network. Indicator will then blink 5 times  quickly for successful pairing.

Note:

  1. After pairing successfully, the remote information will appear on the controller or hub interface.
  2. No remote information wiII appear on the hub interface if pairing to Philips Hue Bridge.

Touch Link to a Zigbee Lighting Device
Operation instruction
Step 1:
Set the zigbee lighting device to start Touch Link  commissioning, please refer to its manual to learn how.
Step 2: Bring the remote within 10cm of the lighting device
Step 3: Short press ON button of group 1/2/3/4 to choose a group  that you would like to pair the  device to.
Step 4 : Press and hold down both until LED indicator turns on.
Step 5: Immediately short press to  start Touch Link commissioning of the remote. LED indicator flash fast for 3S, then flash 6 times slowly to indicate successful pairing to the device and the light connected to the device will blink twice.

Note:

  1. Directly Touch Link (both not added to a Zig Bee network), please first factory reset both the remote and device, each remote can link with max. 30 devices, please make sure the fi rst linked device is always powered on when touch link the remote with 2nd device and more devices.
  2.  Touch Link after both added to a Zig Bee network, each device can link with max. 30 remotes.
  3. To control by both remote and hub, add both remote and device to network first then TouchL ink, after Touch Link, the device can be controlled by the linked remotes and Zigbee hub together.

Removed from  a Zig bee Network through Coordinator or Hub Interface

Coordinator or Hub Interface

Factory Reset Manually

Factory Reset Manually

Step 1: Press and hold down both until LED indicator turns on.
Step 2:
Immediately short press 5 times continuously, indicator flashes 3 times quickly to indicate successful reset.

Note: All configuration parameters will be reset after the remote is reset or removed from the network.

Remove a Touch link Paired ZigBee Lighting Device

Lighting Device

Step 1: Set the Touch link paired zig bee device to start Touch Link commissioning, please refer to its manual to learn how.
Step 2: Bring the remote within 10 cm of the lighting device.
Step 3: Short press ON button of group 1/2/3/4 to choose a group.
Step 4: Press and hold down both until LED indicator turns on.
Step 5: Immediately short press twice to start Touch Link removing of the remote. LED Indicators .

Factory Reset a Lighting Device (Touch Reset)

Note: the device shall be added to a network, the remote added to the same one or not added to any network.
Factory Reset a Lighting Device
Step 1: Set the zigbee device to start Touch Link commissioning refer to its manual.
Step 2: Bring the remote within 10cm of the lighting device
Step 3: Press and hold down both until LED indicator turns on.
Step 4: Immediately short press 5 times to start Touch Reset of the remote. LED indicator flashes fast for 3S, then flash 3 times slowly to indicate successful reset.

Find and Bind a Zigbee Lighting Device

Note: Make sure the device and remote already added to the same zigbee network.
Lighting Device

Step 1: Start find and bind mode on the Zigbee lighting device (initiator node) and enable it to find and bind target, refer to its manual.
Step 2: Short press button of group 1/2/3/4 to choose a group that you would like to bind the device to.
Step 3: Press and hold down both until LED indicator turns on
Step 4: Short press to enable the remote (target node) to find and  bind initiator. LED indicator flashes 4 times for successful binding or twice if binding fails.
Note: Each remote can bind max. 30 Lighting devices.

Find and Unbind a Zig bee Lighting Device

Lighting Device

Step 1: Start find and bind mode on the Zig bee lighting device (initiator  node) and enable it to find and bind target, refer to its manual.
Step 2: Short press button of group 1/2/3/4 to choose the group that the device already bound to.
Step 3: Press and hold down both.
Step 4: Short press twice to enable the remote (target node) to find and unbind initiator. LED indicator flashes 4 times for successful unbinding or twice if unbinding fails.

Clear All Find and Bind Mode Paired Lighting Devices

Paired Lighting Devices

Step 1: Short press button of group 1/2/3/4 to choose the group that you would like to unbind all devices.
Step 2: Press and hold down both until LED indicator turns on.
Step 3: Short press 5 times continuously to clear all bound Iighting devices . LED indicator flashes 4 times for successful unbinding.

Setup a Network & Add Devices to the Network (No Coordinator or Hub

Required)

Setup a Network

Step 1: Factory reset the remote and the lighting device, refer to  their manuals.
Step 2: Touch Link the remote and device to setup a network, refer to their manuals.
Step 3: Press and hold down both until LED indicator turns on.
Step 4: Short press button to enable the network to discover and  O add devices, LED indicator will flash twice. 180 seconds timeout, repeat the operation .
Step 5: Set another remote into network pairing mode and pair it to  the network, refer to its manual.
Step 6: Add more remotes to the network as you would like. < 10 cm
Step 3: Press and hold down both until LED indicator turns on.
Note: Each remote can bind max. 30 Iighting devices.
Step 7: Factory reset the Iighting devices that you would like then add them to the network, refer to their manuals.
Step 8: Touchlink to pair the added remotes and lighting devices, refer to their manuals. Each remote can link with max. 30 lighting devices. Each lighting device can be linked by max. 30 remotes.

OTA

The remote supports firmware updating through OTA, and will acquire new firmware from zigbee controller or hub every 10 minutes automatically.

How to Check Whether the Remote Belongs to a Network or not

Short press any button, indicator blinking means the remote has already been added to a network, no blinking of indicator means the remote does not belong to any network.

Battery Power Monitor Function

The remote will report battery power vaIue to the coordinator under following situations:

  • When powered on.
  • When short pressing both | and O buttons of group 2 simultaneously.
  • When operating the switch to send data packets (over 4 hours since last operation).
  • When added to the network by a coordinator.

Installation

  1. Remove battery insulator
    Installation instruction

  2. Install the controller to wall(2 methods)
    Installation instruction

Mounting

The key part of this controller is an universal one, especially rotary standard switch element that can be integrated in numerous frames by different manufactures as below list:

BERKER S1, B1, B3, B7 glass
GIRA Standard 55, E2, Event, Esprit
JUNG A500, Aplus
MERTEN M-smart, M-Arc, M-PIan

CAUTION
Risk of explosion if the battery is replaced by an incorrect type

  • replacement of a battery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium battery types);
  • disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion;
  • leaving a battery in an extremely hiph temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas;
  • a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals