WOSPORTS H-101 Rechargeable Golf Range Finder User Guide
- June 5, 2024
- WOSPORTS
Table of Contents
- Parts Of Device
- LCD Display Description
- List of Accessory
- LCD Display Description
- Power On/power Off
- Unit/ Mode Switching
- Basic Operations
- Ranging + Angle Mode
- Flag Pole Lock Mode
- Slope Correction Mode
- Ranging + Height Mode
- DIPSwitch
- Battery
- Golf Slope Correction Use Scenes
- Safety Precautions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WOSPORTS H-101 Rechargeable Golf Range Finder
Parts Of Device
LCD Display Description
Range: 6-1000(m)
Angle Measuring Accuracy: ±1 °
Angle Measuring Range: -60°-60°
Laser type: 905nm (Class 1 laser)
Magnification: 6-1 000(m)
Exit Pupil Diameter: 6X
Object Lens Size: 24mm
Field Angle: 7 .5°
Battery: Built-in lithium battery
Weight: 159g
Dimensions: 113mm80mm43mm
Operating Temperature: 10°C-50°c
List of Accessory
- Laser Rangefinder(1 pcs)
- USB Cable(1 pcs)
- Operation Manua1(1 pcs)
- Box(1 pcs)
- Carry Bag(1 pcs)
- Lens Cloth(1 pcs)
LCD Display Description
- Electricity icon
- Angle unit icon
- Vertical height icon
- Angle/ Horizontal distance/ Vertical hight value
- Target icon
- Meter
- Yard
- Range data
- Flag pole icon
- Measurement mode code icon
- Measurement symbol icon
- Angle/Height negative sign icon
Power On/power Off
Poweron
Short press thee button to turn on.
The LCD screen displays the logo of the last shutdown.
Power off
The machine will shut down automatically after 8 seconds if no any operations.
Unit/ Mode Switching
Unit setting:
In the boot state, press the mode button for more than 2 seconds, then unit
switch can be activated. The unit can be switched and retained after the mode
button released.
Mode switching:
In the boot state,press the Mode button and keep less than 2 seconds, then
measurement mode switch can be activated.
Basic Operations
| Single
measurement:
Short press the button to start the single measurement.
---|---
| Continuous
measurement:
Press the button and keep over 2 seconds.the data displayed alternately on the
LCD screen, and the target sign”+”will show on the screen until release the
button .
| Failure
measurement :
The product will shutdown automatically after 8 seconds if no any operations.
Press the Rang button again and it will start on. Noted: If the measure fails,
the data on the screen will be displayed as:”—-“
Ranging + Angle Mode
Operation Method:
In the mode, short press the button after targeting, the angle would be
displayed on the top of the screen ,and the distance would be displayed on the
bottom. (long press for continuous measurement)
- If the data shows a”-” sign means that this angle is a depression angle when measuring the angle.
- Turn on the DIP switch in this mode to directly enter the slope correction mode.
Flag Pole Lock Mode
Operation Method:
Short press the button and release it after aiming at the flagpole, then scan
both sides of the flagpole (flag part) with the target center ,the distance to
the flagpole is displayed at the bottom of the screen and when the icon stops
flashing and the body vibrates .
Turn on the DIP switch in this mode to directly enter the slope correction
mode
Slope Correction Mode
This mode (turn on the DIP switch and switch from M1 / M2 mode to slope
correction) is mainly used for flagpole lock and slope correction.
Operation Method:
Short press the button and release it after aiming at the flagpole, then scan
both sides of the flagpole (flag part) with the target center ,the distance to
the flagpole is displayed at the bottom of the screen and when the icon. stops
flashing and thebody vibrates. The Slope Correction Distance would be
displayed on the top of the
Ranging + Height Mode
Operation Method:
In the mode, short press the button after targeting, the height data would be
displayed on the top of the screen ,and the distance would be displayed on the
bottom.
- If the data shows a”-” sign means that the target is lower than the measurer when measuring height.
DIPSwitch
Dip switch can quickly switch from M1 / M2 mode to slope correction mode .
Operation Method:
In M1 / M2 mode, turn on the DIP switch (toggle to the left) to directly enter
the slope correction mode.
Battery
Full Power
Low battery, please charge
Battery Life: more than 5000 times (25°C).
The Battery: Built-in lithium battery
Red light: Charging
Green light: Charging is complete
Golf Slope Correction Use Scenes
You could get the slope correction distance using AB distance and angle according to golf track formula.
When uphill, the hitting distance is far
AB=AD , if you want hit to B point ,you would hit like parabola 2 instead
parabola 1 when uphill. Slope correction distance is AE
When downhill, the hitting distance is shorter
AB=AD , if you want hit to B point ,you would hit like parabola 2 instead
parabola 1 when downhill . Slope correction distance is AE.
Safety Precautions
Transport/Storage/Maintenance/Disposal
Transport: Please add enough cushioning material in the box to avoid
damaging.the machine while in transport. When the machine falls on the ground,
and makesa strange noise, please remove the battery immediately and stop
using.
Storage : Please keep the product out of reach of children. Don’t put it
on a high and unsteady place to prevent falling on the ground. Do not place
the product in a high temperature environment or it may cause damage of the
products.
Maintenance : If the product is used in rapidly changing temperature, The
lens surface will covered by fog. So please don’t use it before the fog
evaporates.Please clean with lens cloth but not your hands when it is dirty,
or it may cause damage to the glass coating .
Disposal : The product package and discarded products should berecycled
or disposed properly in accordance with local laws.
This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.Shielded interface cable must be used with the equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules. Specifications and designs are subject to change without any notice or obligation on the part of the manufacturer.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>