GE current HORT171 Arize Factor Horticulture LED Lighting System Installation Guide
- June 5, 2024
- GE current
Table of Contents
- GE current HORT171 Arize Factor Horticulture LED Lighting System
- Components Provided
- Lightbar Specifications
- LED Driver Specifications
- Accessories
- Interconnection Cable Specifications
- Universal Cable Mount
- Mounting Distance
- 1 Installation of the Lightbar
- 2 Installation of the Driver
- 3 Electrical Connections
- 4 Connecting Wired Dimming (Optional)
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GE current HORT171 Arize Factor Horticulture LED Lighting System
Installation Guide
WARNING
RISK OF ELECTRIC SHOCK
- Turn power off before inspection, installation or removal.
- Properly ground electrical enclosure.
RISK OF FIRE
- Follow all IEC and local building codes.
- Use only IEC approved wire for input/output connections. Minimum size 3G 0.75mm2.
CAUTION
- Do not operate the product with damaged parts.
- Turn off power before inspection, installation or removal.
- Luminaire may fall down if not installed properly.
- Wear work gloves to prevent dirt and oil from being transferred to the luminaire.
- Not for direct exposure to the weather.
- To ensure the product warranty is valid, please ensure all installation instructions and environmental conditions for storage and operation are complied with.
- The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
- Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
- For safe operation, and to maximize the longevity of the luminaire; ensure that the lightbar and driver are clean and free of dirt, dust, oil, or any other debris.
- Do not apply any kind of film on the lens or otherwise cover the driver or light engine in any way.
- The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.
Components Provided
- ML series lightbar (see Lightbar Specifications below)
- Driver bracket (93155678)
- Suspended mount wireform support (93153914)
- Factor driver hanger (93153268)
- Shorting cap (95050824)
- DC adapter cable (93154527)
- 1 meter AC input leader cable (93149021)
Lightbar Specifications
LED Driver Specifications
Accessories
Interconnection Cable Specifications
Universal Cable Mount
Mounting Distance
1 Installation of the Lightbar
1.1 Suspended Mount Installation Steps
Using two wireform supports (GEMB-BANE), the ML Series lightbar can be suspended on a support structure (A) or on cables as shown above (B and C).
Attach wireform supports by pushing up into the slots on the underside of the lightbar.
2 Installation of the Driver
2.1 Installation of Standard Hanger Bracket
Standard hanger bracket fits over a 41 mm Unistrut. If not preassembled, install bracket onto driver.
2.2 Installation with Offset Hanger
Offset hanger used with the standard hanger bracket to clear the bottom of the 41 mm Unistrut.
2.3 Installation with Universal Cables
ATTENTION: Before attempting to install units or maintenance, ensure power is off.
3 Electrical Connections
3.1 Shorting Cap Installation
RISK OF SAFETY AND PRODUCT DAMAGE. DO NOT MAKE OR
BREAK ELECTRICAL CONNECTION WHILE POWER IS APPLIED.
ML900 Electrical Connection: 2 Lightbars only
ML 300 Electrical Connection: 4 to 8 Lightbars only
3.2 Connect the Driver Output to Light Module
3.3.1 Connect the Driver Input
3.4 Connection Schematic
4 Connecting Wired Dimming (Optional)
WARNING
RISK OF ELECTRIC SHOCK
Turn power off before installation, inspection, cleaning or removal. And
follow appropriate lock out/tag out safety procedure.
NOTE: Arize Factor dimming allows user to adjust the light output from 0%/10-100%. When set to 0%, the system will enter standby mode, consuming 0.5-1.5W and LEDs may remain very faintly lit. If 0 light is preferred, switch off the unit via the mains (AC line).
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any
questions, contact the manufacturer.
For the latest install guides for your product go to:
https://www.gecurrent.com/eu-en/indoor-lighting/horticulture-led-grow-lights
arize.support@gecurrent.com
UK and EU company information for UKCA and CE procedure:
Current Lighting Limited, 3rd Floor, 1 Ashley Road, Altrincham, UK, WA14 2DT
Current Netherlands B.V., Programmeurstraat 6, 1033MT Amsterdam, Netherlands
Electrical products must not be thrown out with domestic waste. They must be
taken to
a communal collecting point for environmentally friendly disposal in
accordance with
local regulations. Contact your local authorities or stockist for advice on
recycling. The
packaging material is recyclable. Dispose of the packaging in an
environmentally friendly
manner and make it available for the recyclable material collection-service.
Horticultural lighting. Not suitable for household illumination.