Biocontrol HHR5000 V2 with modification C higher User Manual
- June 5, 2024
- Biocontrol
Table of Contents
Biocontrol HHR5000 V2 with modification C higher
Charging the HHR5000
Internal battery charger
- Connect the charger power supply to power outlet and attach the charger plate to the HHR5000 body
- Status LED on the HHR5000 will flash up in green color every 6 seconds and charging will begin
- When charging is done, the charging light will turn off.
- After charging, disconnect the charger plate from HHR5000 and unplug the charger.
External battery charger (Art. no. 107421)
- The External Battery Charger is a battery charging base designed for the HHR5000 battery handgrip
- It is possible to charge up to two battry packs at the same time
- It will charge the battery handgrip in approximately 3 hours
Charging the HHR5000
Charging the battery handgrip
- Connect the charger power supply to power outlet and insert the DC plug of the power supply into the External Battery Charger
- Power light will light up in green color
- Insert the battery handgrip into charger until it stops
- When the battery handgrip is inserted, the green charging light will light up and charging will begin
- Once fully charged, the green charging light will automatically turn off
- After charging, remove the battery handgrip from charger and unplug the charger
Note!
If the red light will light up charging is not possible. Disconnect the
battery and reconnect again. If the red light is still on, the battery is
wornout or damaged.
Caution
- Use only the AC adapter specified for this product
- To reduce risk of injury, charge only oryginal BioControl type rechargeable batteries. Other types of batteries may burst causing personal injury and damage
- Do not charge the battery handgrip in presence of flammable liquids or gases
- Do not expose charger to rain or snow
Establishing Connection
USB connection
- To connect HHR5000 and PC with USB interface, simply connect HHR and PC with included USB cable
- A window will automatically open on your computer
Click the Open folder to browse files
Bluetooth connection
HHR5000 is equiped with a mobile phone application, which supports real time connection
To connect the HHR5000 device with the mobile phone application:
- Turn on the HHR5000
- Download and run the HHR5000 mobile application
- The mobile application will automatically connect with your HHR5000 device
Demo Application
Main Menu
HHR5000 Demo application has 4 menu entries. When the HHR5000 is launched, you will see the following screen.
The status bar is at the top of the display. Time, battery status and current connections like Bluetooth are displayed.
Demo Application
ISO Reader Menu
Read ISO
Is used for reading RFID tag after pressing the button. When the device reads
a tag, it immediately displays it in a designated field above.
Continuous
This function turns on continuous reading of transponder, it displays each
transponder number in the field and stores it with time stamp in memory. You
can break continuous reading by pressing Continuous button.
Tuning
This function displays tuning parameters of antenna.
NFC Reader Menu
Read NFC
Is used for reading NFC tag after pressing the button. When the device reads a
tag, it immediately displays it in a designated field above.
Continuous
This function turns on continuous reading of NFC transponder, it displays each
transponder number in the field and stores it with time stamp in the memory.
You can break continuous reading by pressing Continuous button.
Read/Write
Besides standard tag reading, there is a designated field to enter and store
information on the NFC tag.
Test Menu
ISO
Turns on or off continuous reading of RFID transponder
NFC
Turns on or off continuous reading of NFC transponder
LCD
Turns off LCD screen, to turn it on press any key on keyboard
LEDS
Turns LED on or off
Buzzer
Turns sound buzzer on or off
Vibration
Turns vibrations on or of
Info Menu
Tuning status
Antenna voltage and tuning values are displayed
Battery status
Battery voltage and percentage are displayed
Bluetooth
MAC address and device name are displayed
Firmware
Current firmware version:
HHR main unit
ISO RFID reader
NFC – reader
Bootloader
Enables updating HHR5000 firmware using your computer
HHR5000 Care
The rugged design makes the HHR5000 fit for challenging circumstances, but you still need to take care of it. The following instructions will help you get the most out of your HHR5000 in real life circumstances.
The body
Clean the HHR5000 with a soft cloth dampened with either water or a diluted
mild detergent.
Note: if a mild detergent is used, carefully rinse with water to ensure all
residue is removed.
The screen
Protect the display from impact, pressure, or abrasive substances that can
scratch or crack it.
Temperature
Even though the HHR5000 is designed to be rugged, do not leave it in direct
sunlight or in a vehicle in the sunlight for extended periods.
Batteries perform best at room temperature. The battery has a stable capacity when temperatures rise, but at lower the temperatures battery life may be reduced. When working in extremely cold conditions, battery performance will improve if you keep the HHR5000 warmer than the surrounding air if it is not being used. (e.g. keeping in a vehicle or in a jacket pocket).
Specification
Supported tag standards | FDX, HDX, B-transponders, NFC |
---|---|
Standards | ISO11784/5, ISO14443A/B, ISO15693, ISO18000-3 and Tag-it |
Interface | USB, Bluetooth |
Battery | 2×18650 LiIon batteries in series with protection circuitry |
Battery charger output | 8,2V/1,3A |
Battery life | 5 years |
Power supply | External wall plug-in 12VDC/3A |
Operating temperature | -20°C / +55°C |
Long term storage temperature | 0°C / +45°C |
Charging temperature | +5°C / +45°C |
Weight | HHR5000SN for smart phone w/NFC HHR5000LN with display and NFC 814g |
760g
Dimensions| 63,8×6,7×7,9 cm
Shock withstands| 2 drops from 1 m
Humidity| IP67