CFE energy storage system POWER STORM-1200 Portable Battery Pack User Manual

June 3, 2024
CFE energy storage system

CFE energy storage system POWER STORM-1200 Portable Battery Pack

CFE-energy-storage-system-POWER-STORM-1200-Portable-Battery-Pack-
product

GENERAL SPECIFICATIONS

ThePOWERSTORM-1200 is a portable battery pack with the ability to supply 1200W of pure sine wave AC power via the onboard AC output. Additionally, The POWERSTORM- 1200 is able to support USB quick charging via the onboard 2 x USB-PD port and 4 x USB-A ports. Support AC super quick charging via AC cable. Overall storage capacity is 999Wh of energy.

WARNINGS

To ensure safe operation and service of the meter, follow these instructions. Failure to observe these warnings can result in severe injury or death.

  • DO NOT use POWERSTORM-1200 in excess of its output rating. Overload outputs above rating may result in a risk of fire or injury to persons, even though we have built-in overload protection.

  • DO NOT use if the POWERSTORM-1200 or AC Wall plug power adapter is damaged or modified. Damaged or modified batteries may behave unpredictably, resulting in a risk
    of fire, explosion, or injury.

  • DO NOT subject to vibration, impacts, or drops. Secure POWERSTORM-1200 during transport. The housing may not show signs of damage, but internal components may have been ompromised. It is advisable to replace it if any such severe events occur.

  • DO NOT expose POWERSTORM-1200 to moisture, rain, or snow.

  • DO NOT charge, use or store POWERSTORM-1200 in a bathroom or in an area exposed to rain or moisture.

  • DO NOT leave children or the persons, who with reduced physical/sensory or mental capabilities/or lack of experience and knowledge, along with POWERSTORM-1200 unless they have been given supervision or instruction concerning use of it by a person responsible for their safety.

  • DO NOT attempt to repair POWERSTORM-1200 or AC Wall plug power adapter.

  • There are no user- serviceable components inside.

  • DO NOT handle POWERSTORM-1200 with wet hands.

  • DO NOT place POWER STORM-1200 on its side or upside down while in use or in storage.

  • If rust, odor, overheating, or other abnormal circumstance are observed, stop using and contact CFE’s customer service.

  • Children should be supervised to ensure that they DO NOT play with the POWER STORM-1200 alone.

  • The POWER STORM-1200 is only used for emergency power station, it cannot replace the standard AC or DC power of household appliances or digital products.

  • Keep away from high voltage electrical fields.

  • Risk of fire and burns, DO NOT open, crush, heat above 113°F (45°C) or incinerate. Follow all instructions.

  • Use of a power supply, charger, or cable not recommended or sold by portable battery manufacturers may result in a risk of fire or injury to persons.

  • Should fluid from inside of POWER STORM-1200 come in contact with your skin or clothing, wash the affected areas with tap water.

  • The accessories included in the box should only be used with the POWER STORM-1200.

  • KEEP THIS PRODUCT AWAY FROM PETS.

FEATURE DETAILS

CFE-energy-storage-system-POWER-STORM-1200-Portable-Battery-Pack-
fig-1

  1. LCD Screen Display
  2. DC Output
  3. Cigarette Lighter Output
  4. USB-A Output
  5. USB-C Output
  6. 1200W Rated AC Output
  7. Anti-collision Strip
  8. Wireless IoT
  9. POWER ON/OFF
  10. SOS MODE & LED light
  11. Wireless Charger
  12. olding Handle
  13. Air Intake Vent with Cooling Fan
  14. PV Input
  15. AC fast charging

Note: No user-serviceable parts inside. Recommended to fully charge the POWER STORM-1200 before use.

BUTTON FEATURE

  • A: DC Output Power ON/OFF Button
  • B: AC Output Power ON/OFF Button
  • C: USB Output Power ON/OFF Button
  • D: Master power ON/OFF Button
  • E: SOS mode & LED light Button
  • F: Wireless ON/OFF Button

LCD FEATURES

CFE-energy-storage-system-POWER-STORM-1200-Portable-Battery-Pack-
fig-3

  • G: Remaining time available
  • H: Cell temperature
  • I: Cell average voltage
  • J: Output Status flag
  • K: Warning/error Status
  • L: Charging input power
  • M: Output power
  • N: Battery Level indicator
  • O: Output power curve

HOW TO CHARGE

CFE-energy-storage-system-POWER-STORM-1200-Portable-Battery-Pack-
fig-4

DO NOT CONNECT DEVICE VIA AC OUTPUT PORT WHILE CHARGE THE POWERSTORM-1200.RECOMMEND TO DISCONNECT THEPOWERSTORM-1200 WHEN FULLY CHARGED

WHAT IT POWERS

CFE-energy-storage-system-POWER-STORM-1200-Portable-Battery-Pack-
fig-5

FUNCTION BUTTONS

DC OUTPUT POWER ON/OFF A
The DC output port will NOT function until the appropriate Button A & D are both pressed to activate. Press Button D to shut down the output(s) When not in use.

AC OUTPUT POWER ON/OFF B
The AC output port will NOT function until the appropriate Button B & D are both pressed to activate. Press Button D to shut down the output(s) When not in use.

USB-A/C OUTPUT C
The USB-A/C output port will NOT function until the appropriate Button A&D are both pressed to activate.The USB-A/C cable of different devices need different endorsements of corresponding protocols.

POWERSTORM-1200 POWER ON/OFF D

  • Button D is the master switch. Press Button D to activate the button A/B/C/F.
  • Press Button D to shut down the output(s) When not in use.

SOS MODE & LED LIGHT E

  • Function available no matter the Button A activate or not.
  • First, press Button E to turn on the LED light;
  • Second, DOUBLE-Press to turn on the SOS mode;
  • Third, press Button E back to LED light, one more time again, will turn off the light.

Wireless IoT ON/OFF F
The IoT APP function will NOT function until the appropriate Button A & D are both pressed to activate. Press Button D to shut down the IoT function When not in use.

WIRELESS CHARGER(11)
Press ON/OFF Button D before charging. Press ON/OFF Button to shut down the output(s) When not in use.

COOLING FAN(13)
POWERSTORM-1200 utilizes an internal cooling fan to ensure the product is operating within the appropriate temperature range.when it experiences a higher output load, will automatically turn intermittently to keep internal temperature within operating range. During discharge, and possibly charging, the fan may operate the AC circuit is activated to ensure proper operation.

POWERING / CHARGING DEVICES WITH POWERSTORM-1200

BATTERY LEVEL INDICATOR N

The battery level is displayed as a percentage of the battery Charge corresponding to the number of circular ring and percentage displayed. The segments in the battery level correspond to the current state of charge, 0-5%empty, 6-20% ten segment, 21-40% twenty segments, 41-60% thirty segments, 61-80% fortieth segments, and all are lit when charge level is above 81%. Provides users with real-time telemetry data in time to fully charge or drain the battery.
It is strongly recommended to fully charge the POWERSTORM-1200 when using it for the first time. The higher the battery level indicator shows, the more precise data will indicate.
PLEASE BE AWARE that this value can adjust multiple times as the energy draw changes from the connected devices. This is evident during initial activation of ports with a connected device.
RECOMMENDED back to charge the POWERSTORM-1200 when battery indicate less than 20%. Note that when you first plug in a power source, whether it’s a solar panel or a wall charger, the POWERSTORM-1200 may take a minute to detect and adjust its charge circuitry before it starts drawing power from the source.

  • INPUT Status N: The POWERSTORM-1200 is capable of providing input energy in watts.
  • DC Output Status J: The display will provide output watts of the DC port(2)(3)(4)(5).
  • AC Output Status K: The display will provide output watts of the AC port(6).

The output watts of USB port will NOT display on the LCD Screen(1). LCD Screen(1)will enter sleep mode after 120 seconds of inactivity (no new output load detected), and will “wake up” when inputting a charging cord or when any button is pressed.

OPERATING INSTRUCTIONS

CHARGING POWERSTORM-1200
Connect the provided AC Wall power cable to Input(15), and allow POWERSTORM-1200 to fully charge prior to use, approx. 1.6-1.7 hours. When charging, the LCD Screen(1)will be illuminated, and the LCD display will provide Battery level Indicator H , POWERSTORM- 1200 is fully charged when the level is 100%. It is recommended to fully charge POWERSTORM-1200 every 3 month to maintain the health of the battery pack.

Select the type of outlet required by pressing the Output ON/OFF Button C/D/E. The output port will NOT function until the appropriate button is pressed to activate the port. When activated, the indicator on the button will illuminate green, indicating that the output(s) are active, and the LCD display will turn on and provide details on the charging output. The LCD Screen will automatically shut down when no outputs are activated. POWER STORM-1200 will enter sleep mode after 120 seconds of inactivity (no new output load detected), and will “wake up” when inputting a charging cord or when any button is pressed. Press the ON/OFF button(s) to shut down the output(s) when not in use.

PASS-THROUGH CHARGING
The advanced battery management system of the CFE’s POWER STORM-1200 allows it to charge a connected device via DC output & USB output while charge the POWER STORM-1200. DO NOT CONNECTED THE DEVICE VIA AC OUTPUT WHILE CHARGING THE POWERSTORM-1200.

OVERLOAD CONDITION
If an overload condition occurs on the OUTPUT port, POWER STORM-1200 will: Automatically turn off AC Output(6)power. The blue indicator light of LCD Screen(1)still illuminated. DC OUTPUT Status J still the same status as usual.

Do following:
Check the input charge cable. The port will be efficient when the input charge cable meets the specification outlined in the GENERAL SPECIFICATIONS section. Only charge POWER STORM-1200 with provided AC wall power adapter.

POWER STORM-1200 ACCESSORY LIST

CFE-energy-storage-system-POWER-STORM-1200-Portable-Battery-Pack-
fig-7

Recommend to use 300W Solar panel (not included).

CLEANING

Be sure that POWERSTORM-1200 is disconnected from all input power sources and output devices. Use a clean, dry, soft-lint-free cloth to wipe down it. Remove any debris, dirt, or other blockages on both side vents. When cleaning debris from the side vents, do not allow the debris, dirt, or other blockages to enter the body of POWERSTORM-1200.

  • DO NOT use abrasive cleaners or solvents.
  • DO NOT use compressed air to clean side cooling vents, as this will force foreign particles into the internal circuitry.

To avoid the risk of electrical shock, DO NOT use metal objects to clean ports.

STORAGE

If storing for more than 1 month, charge completely before storage and recharge approximately every 3 months to avoid full discharge and possible damage. Store indoors, in cool temperatures, mild humidity, and away from direct sunlight (See GENERAL SPECIFICATIONS section). Leaving in a vehicle or other confined spaces in extreme hot temperatures can lead to decreased service life, overheating, and fire. Extreme cold conditions below specific storage range can also harm POWERSTORM-1200 performance and service life. Keep away from corrosion chemicals and gases. After taking out of storage, visually inspect to make sure POWERSTORM-1200 and all accessories look satisfactory. This increase review the intake and exhaust side vents to ensure they are clear of debris. Allow POWERSTORM-1200 to return to ambient conditions before recharging, or charging other devices.

ATTENTION

Transportation: POWER STORM-1200 complies with all legal requirements for transport of dangerous goods. The capacity of the lithium battery pack exceeds 100Wh. Based on international standards, if POWERSTORM-1200 is transported by airplane, it must be transported in accordance with IATA standard packaging. IATA instructions and labeling requirements and the relevant declarations must be completed.CFE-energy-storage-system-POWER-STORM-1200-Portable-Battery-
Pack-fig-6

TROUBLESHOOTING

POWERSTORM-1200 WILL NOT CHARGE OR OPERATE connected devices:
Ensure that the DC/USB/AC output ports(2)/(3)/(4)/(5)/(6)are activated by pressing the Button(s) A & C/D/E for the port(s) in use. Confirm the connected device is suitable for the CFE’s POWERSTORM-1200 by reviewing the output specifications provided in the GENERAL SPECIFICATIONS section. Confirm POWESRTORM-1200 is charged by reviewing the Battery Level Indicator H. Verify the watt data displayed on the Status Indicator I/J/K of LCD Screen(1)for overload condition.

POWERSTORM-1200 WILL NOT CHARGE:
Confirm that the wall plug power cable cord is inserted fully into the AC Input(15). Confirm that the AC wall plug power adapter is the charger provided with intelligent energy POWERSTORM-1200. If the input does not comply with the requirements located in the GENERAL SPECIFICATIONS section, the Low Watt range 0 to 10 may be displayed on.

INPUT STATUS I of LCD screen(1).

MAINTENANCE

Recharge as needed. There are no pre-designated intervals at which to recharge as long as the CFE’s POWERSTORM-1200 is being used regularly. Avoid discharging completed on a regular basis, as this can impact overall life. Regularly inspect all ports and wall charger for any debris, dirt, damage and corrosion. DO NOT attempt to fix. DO NOT cover the POWERSTORM-1200 with towels, clothing or other items. Regularly observe if the side vents are collecting dirt or dust, and clean following cleaning procedures noted in manual.

DISPOSAL/RECYCLE

Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations. See www.epa.gov for additional information.

STATEMENT

Copyright CFE. All rights reserved. All trademarks cited herein are the property of their respective owners. The information contained herein is subject to change without notice. The only warranties for products and services are set forth in the warranty statements accompanying such products and services. CFE shall not be liable for technical or editorial errors or omissions contained herein.
Second Edition: Apr 2022. This user guide describes features that are common to most models.

Limited Warranty
Warrants to the original consumer purchaser that the will be free from defects in workmanship and material under normal consumer use during the applicable warranty period identified in the ‘Warranty Period’ section below, subject to the exclusions set forth below. This warranty statement sets forth total and exclusive warranty obligation. We will not assume, nor authorize any person to assume for us, any other liability in connection with the sale of our products.

WARRANTY PERIOD
The warranty period is 12 months. In each case, the warranty period is measured starting on the date of purchase by the original consumer purchaser. The sales receipt from the first consumer purchase, or other reasonable documentary proof, is required in order to establish the start date of the warranty period.

REMEDY
CFE will repair or replace( at CFE’s option) any CFE product that fails to operate during the applicable warranty period due to defect in workmanship or material. If a valid claim is made during the applicable period, CFE, at its option, will either (1) replace the product, or (2) exchange the product with a product that is of equal value. A replacement product assumes the remaining warranty of the original product or ninety (90) days from the date of replacement, whichever is greater. Customer is responsible for the return shipping costs. Limited to Original Consumer Buyer The warranty on product is limited to the original consumer purchaser and to any subsequent owner.

EXCLUSIONS

CFE’s warranty does not apply to (i) any product that is misused, abused, modified, damaged by accident, or used for anything other than normal consumer use as authorized in CFE’s current product literature, or (ii) any product purchased through an online auction house. CFE’s warranty does not apply to the battery cell unless the battery cell is fully charged by you within seven days after you purchase the product and at least every 3 months thereafter.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals